A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

被引:63
|
作者
Clavijo, Claudia F. [1 ,2 ]
Hoffman, Keith L. [1 ]
Thomas, James J. [1 ]
Carvalho, Brendan
Chu, Larry F. [2 ]
Drover, David R. [2 ]
Hammer, Gregory B. [2 ]
Christians, Uwe [1 ]
Galinkin, Jeffrey L. [1 ,3 ]
机构
[1] Univ Colorado Denver, Clin Res & Dev iC42, Dept Anesthesiol, Aurora, CO 80045 USA
[2] Stanford Univ, Dept Anesthesia, Stanford, CA 94305 USA
[3] Childrens Hosp Denver, Aurora, CO 80045 USA
基金
美国国家卫生研究院;
关键词
Morphine; 3; beta-glucoronide; 6; beta-glucuronide; LC-MS/MS; Human plasma; Dried blood spots; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; POSTOPERATIVE PAIN; BODY-FLUIDS; MORPHINE-6-GLUCURONIDE; PHARMACOKINETICS; SERUM;
D O I
10.1007/s00216-011-4775-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-mu m PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25-1000 ng/mL (r (2) > 0.99) for morphine, 1-1,000 ng/mL (r (2) > 0.99) for M3G, and 2.5-1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1-1,000 ng/mL (r (2) > 0.99) for morphine and M3G, and of 2.5-1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20-50 mu L.
引用
收藏
页码:715 / 728
页数:14
相关论文
共 50 条
  • [21] Multiplexed quantification of venlafaxine and metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pandey, Aashish
    Price, Amelia
    Ayala-Lopez, Nadia
    Garza, Kyana Y.
    Marzinke, Mark A.
    Knezevic, Claire E.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 243
  • [22] Determination of Methylphosphonic Acid in Human Blood Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Baygildiev, T. M.
    Rodin, I. A.
    Stavrianidi, A. N.
    Braun, A. V.
    Shpigun, O. A.
    Rybalchenko, I. V.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (13) : 1307 - 1311
  • [23] High-throughput liquid chromatography-tandem mass spectrometry assay for plasma theophylline and its metabolites
    Song, J
    Park, KU
    Park, HD
    Yoon, Y
    Kim, JQ
    [J]. CLINICAL CHEMISTRY, 2004, 50 (11) : 2176 - 2179
  • [24] A liquid chromatography-tandem mass spectrometry assay for quantification of rilpivirine and dolutegravir in human plasma
    Gregoire, M.
    Deslandes, G.
    Renaud, C.
    Bouquie, R.
    Allavena, C.
    Raffi, F.
    Jolliet, P.
    Dailly, E.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 971 : 1 - 9
  • [25] Analytical and clinical validation of a dried blood spot assay for the determination of paclitaxel using high-performance liquid chromatography-tandem mass spectrometry
    Andriguetti, Natalia B.
    Hahn, Roberta Z.
    Lizot, Lilian F.
    Raymundo, Suziane
    Costa, Jose L.
    da Cunha, Kelly F.
    Vilela, Ramon M. M.
    Kluck, Helena M.
    Schwartsmann, Gilberto
    Antunes, Marina V.
    Linden, Rafael
    [J]. CLINICAL BIOCHEMISTRY, 2018, 54 : 123 - 130
  • [26] Determination of repaglinide in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Jie
    Gao, Feng
    Guan, Xin
    Sun, Yan-tong
    Gu, Jing-kai
    Fawcett, J. Paul
    [J]. ACTA PHARMACEUTICA SINICA B, 2011, 1 (01) : 40 - 45
  • [27] Dried plasma spot assay for sunitinib and its active metabolite by high performance liquid chromatography tandem mass spectrometry
    Makihara, R. A.
    Maeda, M.
    Itahashi, K.
    Noda, S.
    Sato, J.
    Murakami, S.
    Goto, Y.
    Kanda, S.
    Fujiwara, Y.
    Horinouchi, H.
    Tsukamoto, T.
    Hashimoto, H.
    Makino, Y.
    Yamamoto, N.
    Ohe, Y.
    Terakado, H.
    [J]. ANNALS OF ONCOLOGY, 2017, 28 : 171 - 171
  • [28] Quantitation of iptakalim in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Teng, Guosheng
    Wang, Yingwu
    Tang, Yunbiao
    Wang, Rui
    Fang, Yi
    Fawcett, J. Paul
    Gu, Jingkai
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (02): : 256 - 260
  • [29] Determination of beraprost in human plasma by a high-performance liquid chromatography-tandem mass spectrometry
    Lee, J.
    Kim, H.
    Jeong, J. C.
    Park, E. S.
    Hwang, K. W.
    Yang, S. J.
    Jeong, J. H.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (02): : 229 - 233
  • [30] Determination of eupatilin in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Kim, IK
    Kim, SH
    Kim, WB
    Lee, HS
    [J]. CHROMATOGRAPHIA, 2004, 59 (7-8) : 425 - 428