Comparison between Modified and Unmodified Carbon Paste Electrodes for Hexavalent Chromium Determination

被引:21
|
作者
Hilali, Nazha [1 ]
Ghanam, Abdelghani [1 ]
Mohammadi, Hasna [1 ]
Amine, Aziz [1 ]
Jose Garcia-Guzman, Juan [2 ]
Cubillana-Aguilera, Laura [2 ]
Maria Palacios-Santander, Jose [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Genie Proc & Environm, BP 146, Mohammadia 20800, Morocco
[2] Univ Cadiz, Dept Analyt Chem, Fac Sci, Inst Res Electron Microscopy & Mat IMEYMAT,Campus, Campus Univ Puerto Real,Polgono Rio San Pedro S-N, Cadiz 11510, Spain
关键词
Carbon paste electrodes; Diphenylcarbazide; Gold nanoparticles; Hexavalent chromium; Speciation; STRIPPING VOLTAMMETRIC MEASUREMENTS; SOLID-PHASE EXTRACTION; GOLD NANOPARTICLES; ELECTROCHEMICAL DETECTION; WATER SAMPLES; CR(VI); SPECIATION; IONS; INTERFERENCES; NANOCOMPOSITE;
D O I
10.1002/elan.201800505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work consists of developing a simple electroanalytical method which allows the speciation of Cr(VI). Gold modified Carbon Paste Electrodes (CPEs) and unmodified CPEs have been tested for the determination of Cr(VI) in presence of an excess of Cr(III) by using differential pulse voltammetry (DPV), without any accumulation or pre-concentration time. Several parameters affecting the analytical performances of the designed electrodes were investigated, including: electrodeposition technique of AuNPs onto the CPE, amount of AuNPs dropped on the electrode surface, supporting electrolyte, presence of Cr(III), presence of chloride ions and concentration of diphenylcarbazide (DPC). Under the optimal conditions, the use of unmodified CPE in an acidic medium containing DPC exhibited a high selectivity and a good detection limit of 19 mu g L-1, which is much lower than the admissible concentration fixed by the World Health Organization (50 mu g.L-1). A linear range from 50 to 260 mu g.L-1 was obtained with a relative standard deviation of 7.75 %. Furthermore, as opposed to the AuNPs-modified CPE, the current response of Cr(VI) obtained at the unmodified CPE was not affected by the presence of chloride ions and trivalent chromium. Finally, the proposed method was successfully applied for the determination of Cr(VI) in real tap water samples with satisfactory results.
引用
收藏
页码:2750 / 2759
页数:10
相关论文
共 50 条
  • [1] A Comparison of Variously Modified Carbon Paste Electrodes for Determination of Rutin
    Macikova, Pavla
    Skopalova, Jana
    MODERN ELECTROCHEMICAL METHODS XXX, 2010, : 101 - 105
  • [2] Testing of unmodified carbon paste electrodes
    Svancara, I
    Schachl, K
    CHEMICKE LISTY, 1999, 93 (08): : 490 - 499
  • [3] An oxidative procedure for the electrochemical determination of chromium(VI) using modified carbon paste electrodes
    Sánchez-Fernández, ME
    Cubillana-Aguilera, LM
    Palacios-Satander, JM
    Naranjo-Rodríguez, I
    de Cisneros, JLHH
    BULLETIN OF ELECTROCHEMISTRY, 2005, 21 (12): : 529 - 535
  • [4] ALCOHOL DETERMINATION BY MODIFIED CARBON PASTE ELECTRODES
    BILITEWSKI, U
    SCHMID, RD
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 99 - 102
  • [5] Voltammetric study of nifuroxazide at unmodified and Sephadex-modified carbon paste electrodes
    A. Radi
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 590 - 594
  • [6] Voltammetric study of nifuroxazide at unmodified and Sephadex-modified carbon paste electrodes
    Radi, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (06): : 590 - 594
  • [7] Modified carbon paste electrodes for Cu(II) determination
    Ghaedi, Mehrorang
    Naderi, Sakineh
    Montazerozohori, Morteza
    Sahraei, Reza
    Daneshfar, Ali
    Taghavimoghadam, Narges
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08): : 2274 - 2279
  • [8] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Fakhrabad, Azam Hosseini
    Khoshnood, Razieh Sanavi
    Ebrahimi, Mahmoud
    Abedi, Mohammad Reza
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (07) : 951 - 957
  • [9] Fabrication of Carbon Paste Electrodes Modified with Multi-walled Carbon Nanotubes for the Potentiometric Determination of Chromium(III)
    Razieh Sanavi Azam Hosseini Fakhrabad
    Mahmoud Khoshnood
    Mohammad Reza Ebrahimi
    Journal of Analytical Chemistry, 2020, 75 : 951 - 957
  • [10] VOLTAMMETRIC DETERMINATION OF CELIPTIUM WITH CARBON PASTE AND LIPID-MODIFIED CARBON PASTE ELECTRODES
    ARCOS, J
    KAUFFMANN, JM
    PATRIARCHE, GJ
    SANCHEZBATANERO, P
    ANALYTICA CHIMICA ACTA, 1990, 236 (02) : 299 - 305