Quantifying injection solvent effects in reversed-phase liquid chromatography

被引:35
|
作者
VanMiddlesworth, Bradley J. [1 ]
Dorsey, John G. [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
基金
美国国家科学基金会;
关键词
Hydrophobic subtraction model; Injection solvent; Diluent; Excess adsorption isotherm; HYDROPHOBIC-SUBTRACTION MODEL; EXCESS ADSORPTION-ISOTHERMS; MOBILE-PHASE; COLUMN SELECTIVITY; SAMPLE SOLVENT; ELUENT COMPONENTS; PERFORMANCE; RETENTION; VOLUME; WATER;
D O I
10.1016/j.chroma.2012.02.075
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peak distortion due to the injection was measured as a function of injection solvent strength, volume, mass, retention factor, and column selectivity. The concept of a method's sensitivity(s) to injection solvent strength was mathematically defined as a vector of theoretical plate counts compared to an ideal vector that does not change with injection solvent strength. Near ideal sensitivity (s > 0.90) was measured on all columns with all analytes in low volume injections of 1.25 mu L. Increasing the injection volume reduces the measured sensitivity from ideality to a greater extent than increasing the injection mass, with differing values for each column. Using column parameters measured from the hydrophobic-subtraction model and fitting parameters from the acetonitrile excess adsorption isotherm, differences among the columns studied are explained. Decreased ligand density and increased silanol activity provide a consistent peak shape with changes in injection volume or solvent strength. For method development, a quick test is suggested with the ratio of hydrophobic-subtraction column parameters, H/A, to predict the injection solvent sensitivity of a column. As H/A decreases, the sensitivity to injection solvent worsens. Sensitivity to organic modifiers other than acetonitrile are predicted with cited sorbed layer thickness, such that MeOH > EtOH > IPA approximate to THF approximate to MeCN, i.e., a strong MeOH diluent is more ideal (better) than a strong MeCN diluent. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 89
页数:13
相关论文
共 50 条
  • [21] RETENTION ANOMALY IN TERNARY SOLVENT SYSTEMS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    LOCHMULLER, CH
    HAMZAVIABEDI, MA
    OU, CX
    JOURNAL OF CHROMATOGRAPHY, 1987, 387 : 105 - 120
  • [22] SYSTEMATIC STUDY OF TERNARY SOLVENT BEHAVIOR IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    SCHOENMAKERS, PJ
    BILLIET, HAH
    DEGALAN, L
    JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3): : 261 - 284
  • [23] SOLVENT SELECTIVITY IN REVERSED-PHASE HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    BAKALYAR, SR
    MCILWRICK, R
    ROGGENDORF, E
    JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV): : 353 - 365
  • [24] SOLVATOCHROMIC SOLVENT POLARITY MEASUREMENTS AND SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JOHNSON, BP
    KHALEDI, MG
    DORSEY, JG
    JOURNAL OF CHROMATOGRAPHY, 1987, 384 : 221 - 230
  • [25] COMPUTATIONAL STRATEGY FOR SOLVENT STRENGTH OPTIMIZATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    CHAMINADE, P
    BAILLET, A
    FERRIER, D
    JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) : 67 - 85
  • [26] SOLVATOCHROMIC SOLVENT POLARITY MEASUREMENTS AND RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JOHNSON, BP
    KHALEDI, MG
    DORSEY, JG
    ANALYTICAL CHEMISTRY, 1986, 58 (12) : 2354 - 2365
  • [27] THE PY SOLVENT POLARITY SCALE - SOLVENT MIXTURES USED IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    STREET, KW
    ACREE, WE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 162 - ANYL
  • [28] ON THE CHROMATOGRAPHY MECHANISM OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    ZHU, PL
    CHROMATOGRAPHIA, 1986, 21 (04) : 229 - 233
  • [29] SOLVENT SELECTIVITY EFFECTS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF FLAVONOID COMPOUNDS
    DONDI, F
    KAHIE, YD
    LODI, G
    BLO, G
    PIETROGRANDE, C
    RESCHIGLIAN, P
    JOURNAL OF CHROMATOGRAPHY, 1989, 461 : 281 - 292
  • [30] Testing of "special base" columns in reversed-phase liquid chromatography - A rational approach considering solvent effects
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) : 135 - 147