Sentinel Node Identification Using Technetium-99m Neomannosyl Human Serum Albumin in Esophageal Cancer

被引:29
|
作者
Kim, Hyun Koo
Kim, SeungEun
Park, Jong Jae
Jeong, Jae Min
Mok, Young Jae
Choi, Young Ho
机构
[1] Korea Univ, Guro Hosp, Coll Med, Dept Thorac & Cardiovasc Surg, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Coll Med, Dept Nucl Med, Seoul 152703, South Korea
[3] Korea Univ, Guro Hosp, Coll Med, Dept Internal Med, Seoul 152703, South Korea
[4] Korea Univ, Guro Hosp, Coll Med, Dept Surg, Seoul 152703, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
来源
ANNALS OF THORACIC SURGERY | 2011年 / 91卷 / 05期
关键词
CELL LUNG-CANCER; LYMPH-NODE; BREAST-CANCER; THORACIC ESOPHAGUS; GASTROINTESTINAL CANCER; 3-FIELD LYMPHADENECTOMY; CARCINOMA; TRIAL; VALIDATION; DISSECTION;
D O I
10.1016/j.athoracsur.2011.01.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. This study is a clinical trial designed to test the reliability and feasibility of sentinel node detection using a new mannose receptor radioactive binding agent in patients with esophageal squamous cell carcinoma. Methods. Twenty-three patients (21 men, 2 women; mean age 61.0 +/- 8.60 years) who were candidates for esophagectomy with conventional lymph node dissection for thoracic esophageal cancer were enrolled. A total dose of 1mCi of (99m)Tc-MSA [technetium-99m neomannosyl human serum albumin] in 0.2 mL was administered at 4 quadrants into the submucosal layer around the primary tumor under esophagoscopic guidance approximately 1 hour before surgery. Intraoperative sentinel node sampling was subsequently followed by esophagectomy. All harvested lymph nodes were cut into 2-mm slices and ultimately diagnosed using formalin-fixed and paraffin-embedded sections with hematoxylin and eosin staining. Results. The number of dissected lymph nodes per patient was 30.5 +/- 9.18 (15-47). Among 23 patients, the sentinel lymph nodes could be identified in 21 patients (91.3%). The sentinel nodes could be identified in all 21 patients with cT1 or T2N0M0 (100%) disease; these patients were candidates for sentinel lymph node navigation surgery for the esophageal cancer. The mean number of sentinel nodes identified was 2.6 +/- 1.35 (range, 1-5) per patient. No false-negative sentinel lymph nodes were detected in any of the 8 patients with node-positive disease (0%). Conclusions. Intraoperative sentinel lymph node identification using (99m)Tc-MSA was feasible and reliable in patients with esophageal squamous cell carcinoma.
引用
收藏
页码:1517 / 1522
页数:6
相关论文
共 50 条
  • [31] CLINICAL COMPARISON OF CARDIAC BLOOD POOL VISUALIZATION WITH TECHNETIUM-99M RED BLOOD-CELLS LABELED INVIVO AND WITH TECHNETIUM-99M HUMAN-SERUM ALBUMIN
    THRALL, JH
    FREITAS, JE
    SWANSON, D
    ROGERS, WL
    CLARE, JM
    BROWN, ML
    PITT, B
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (07) : 796 - 803
  • [32] AFFINITY CONSTANTS OF TECHNETIUM-99M PERTECHNETATE AND TC-CHELATES WITH HUMAN-SERUM ALBUMIN
    DEWANJEE, MK
    BRUEGGEMANN, P
    WAHNER, HW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 132 (03) : 490 - 491
  • [33] HIGH SPECIFIC ACTIVITY TECHNETIUM-99M ALBUMIN
    RICHARDS, P
    ATKINS, HL
    JOURNAL OF NUCLEAR MEDICINE, 1967, 8 (05) : 396 - &
  • [34] NOTES ON PREPARATION OF TECHNETIUM-99M LABELLED ALBUMIN
    LEACH, KG
    EYNON, AL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (01): : 53 - &
  • [35] INDOCYANINE GREEN COMPARED WITH TECHNETIUM-99M FOR SENTINEL LYMPH NODE BIOPSY IN BREAST CANCER: THE FLOURO TRIAL
    Nguyen, C. L.
    Easwaralingam, N.
    Seah, J. L.
    Azimi, F.
    Mak, C.
    Pulitano, C.
    Warrier, S.
    BREAST, 2024, 74
  • [36] BINDING OF TECHNETIUM - 99-M TO HUMAN SERUM ALBUMIN
    WILLIAMS, MJ
    DEEGAN, T
    ENZYMOLOGIA BIOLOGICA ET CLINICA, 1969, 10 (05) : 389 - &
  • [37] Development of 99mTc-MSA (neomannosyl human serum albumin) as a novel receptor binding agent for sentinel node imaging.
    Hong, MK
    Jeong, JM
    Kim, YJ
    Lee, DS
    Chung, JK
    Lee, MC
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 315P - 315P
  • [38] Sentinel lymph nodes with technetium-99m colloidal rhenium sulfide in patients with esophageal carcinoma
    Kato, H
    Miyazaki, T
    Nakajima, M
    Takita, J
    Sohda, M
    Fukai, Y
    Masuda, N
    Fukuchi, M
    Manda, R
    Ojima, H
    Tsukada, K
    Asao, T
    Kuwano, H
    Oriuchi, N
    Endo, K
    CANCER, 2003, 98 (05) : 932 - 939
  • [39] FOREARM BLOOD-FLOW MEASUREMENTS USING TECHNETIUM-99M HUMAN-SERUM ALBUMIN FOLLOWING BRACHIAL ARTERIOTOMY
    PARKIN, A
    SMYE, SW
    BISHOP, N
    WILKINSON, D
    REES, M
    VOWDEN, P
    KESTER, RC
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (01) : 45 - 50
  • [40] PERFUSION OF THE INTERVILLOUS SPACE OF THE HUMAN-PLACENTA MEASURED WITH TECHNETIUM-99M LABELED HUMAN-SERUM ALBUMIN
    ANDERSEN, KV
    ANDERSEN, SV
    MUNCK, O
    LARSEN, JF
    NIELSEN, SL
    KJELDSEN, H
    CLINICAL PHYSIOLOGY, 1982, 2 (02): : 89 - 95