Sentinel Node Identification Using Technetium-99m Neomannosyl Human Serum Albumin in Esophageal Cancer

被引:29
|
作者
Kim, Hyun Koo
Kim, SeungEun
Park, Jong Jae
Jeong, Jae Min
Mok, Young Jae
Choi, Young Ho
机构
[1] Korea Univ, Guro Hosp, Coll Med, Dept Thorac & Cardiovasc Surg, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Coll Med, Dept Nucl Med, Seoul 152703, South Korea
[3] Korea Univ, Guro Hosp, Coll Med, Dept Internal Med, Seoul 152703, South Korea
[4] Korea Univ, Guro Hosp, Coll Med, Dept Surg, Seoul 152703, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
来源
ANNALS OF THORACIC SURGERY | 2011年 / 91卷 / 05期
关键词
CELL LUNG-CANCER; LYMPH-NODE; BREAST-CANCER; THORACIC ESOPHAGUS; GASTROINTESTINAL CANCER; 3-FIELD LYMPHADENECTOMY; CARCINOMA; TRIAL; VALIDATION; DISSECTION;
D O I
10.1016/j.athoracsur.2011.01.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. This study is a clinical trial designed to test the reliability and feasibility of sentinel node detection using a new mannose receptor radioactive binding agent in patients with esophageal squamous cell carcinoma. Methods. Twenty-three patients (21 men, 2 women; mean age 61.0 +/- 8.60 years) who were candidates for esophagectomy with conventional lymph node dissection for thoracic esophageal cancer were enrolled. A total dose of 1mCi of (99m)Tc-MSA [technetium-99m neomannosyl human serum albumin] in 0.2 mL was administered at 4 quadrants into the submucosal layer around the primary tumor under esophagoscopic guidance approximately 1 hour before surgery. Intraoperative sentinel node sampling was subsequently followed by esophagectomy. All harvested lymph nodes were cut into 2-mm slices and ultimately diagnosed using formalin-fixed and paraffin-embedded sections with hematoxylin and eosin staining. Results. The number of dissected lymph nodes per patient was 30.5 +/- 9.18 (15-47). Among 23 patients, the sentinel lymph nodes could be identified in 21 patients (91.3%). The sentinel nodes could be identified in all 21 patients with cT1 or T2N0M0 (100%) disease; these patients were candidates for sentinel lymph node navigation surgery for the esophageal cancer. The mean number of sentinel nodes identified was 2.6 +/- 1.35 (range, 1-5) per patient. No false-negative sentinel lymph nodes were detected in any of the 8 patients with node-positive disease (0%). Conclusions. Intraoperative sentinel lymph node identification using (99m)Tc-MSA was feasible and reliable in patients with esophageal squamous cell carcinoma.
引用
收藏
页码:1517 / 1522
页数:6
相关论文
共 50 条
  • [21] The sentinel node with technetium-99m for prostate cancer. A safe and mature new standard?
    Perez-Ardavin, Javier
    Martinez-Sarmiento, Manuel
    Monserrat-Monfort, Juan J.
    Vera-Pinto, Victor
    Sopena-Novales, Pablo
    Bello-Arques, Pilar
    Boronat-Tormo, Francisco
    Vera-Donoso, Cesar D.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 67 (04): : 287 - 293
  • [22] Endoscopic sentinel lymph node biopsy using indocyanine green-neomannosyl human serum albumin
    Park, Young Min
    Quan, Yu Hua
    Kwon, Ki Hyeok
    Cho, Jae-Gu
    Woo, Jeong-Soo
    Kim, Beop-Min
    Lee, Yun-Sang
    Jeong, Jae Min
    Kim, Hyun Koo
    Song, Jae-Jun
    LARYNGOSCOPE, 2018, 128 (04): : E135 - E140
  • [23] Sentinel node biopsy in melanoma using technetium-99m rhenium colloid: The London experience
    Temple, CLF
    Scilley, CG
    Engel, CJ
    Shum, DT
    Lohmann, RC
    Mattar, AG
    Zabel, PL
    ANNALS OF PLASTIC SURGERY, 2000, 45 (05) : 491 - 499
  • [24] Use of technetium-99m tin colloid for sentinel lymph node identification in non-small cell lung cancer
    Nomori, H
    Horio, H
    Naruke, T
    Orikasa, H
    Yamazaki, K
    Suemasu, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (03): : 486 - 492
  • [25] Stability of the mixture of technetium-99m human serum albumin and lidocaine hydrochloride for clinical application
    Wang, Yuh-Feng
    Chuang, Mei-Hua
    Cham, Thau-Ming
    Chung, Mei-Ing
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (07) : 494 - 497
  • [26] Commentary on sentinel lymph node identification with technetium-99m tin colloid in non-small cell lung cancer
    Liptay, MJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (03): : 428 - 430
  • [27] On-site preparation of technetium-99m labeled human serum albumin for clinical application
    Wang, Yuh-Feng
    Chuang, Mei-Hua
    Chiu, Jainn-Shiun
    Cham, Thau-Ming
    Chung, Mei-Ing
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2007, 211 (04): : 379 - 385
  • [28] Sentinel lymph node biopsy using technetium-99m tin colloids of different sizes.
    Jinno, H
    Ikeda, T
    Kitajima, M
    Fujii, H
    Nakamura, K
    BREAST CANCER RESEARCH AND TREATMENT, 2002, 76 : S128 - S128
  • [29] Comparison of modified technetium-99m albumin and technetium-99m red blood cells for equilibrium ventriculography
    Hambye, ASE
    Verbeke, KA
    Vandermeiren, RP
    Joosens, EJ
    Verbruggen, AM
    DeRoo, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (10) : 1521 - 1528