Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice

被引:48
|
作者
Wu, MC
Gao, DW
Sievers, RE
Lee, RJ
Hasegawa, BH
Dae, MW
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
关键词
D O I
10.1016/S0735-1097(03)00716-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement. BACKGROUND We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-resolution cardiovascular imaging of mice. In this study, we describe a protocol for myocardial perfusion imaging of mice using technetium-99m (Tc-99m)-sestamibi and demonstrate the feasibility for measurement of perfusion defect size from pinhole SPECT images. METHODS Mice were anesthetized and injected with 370 MBq (10 mCi) of Tc-99m-sestamibi. Tomographic projection images were acquired by rotating each mouse in a vertical axis in front of a stationary clinical scintillation camera equipped with a pinhole collimator. BALB/c mice (n = 15) were imaged after the permanent ligation of the left anterior descending coronary artery. The resulting defect size was measured from circumferential profiles of short-axis images. After imaging, the hearts were excised and sectioned to obtain ultra-high resolution digital autoradiographs of Tc-99m-sestamibi, from which the actual infarct size was determined. RESULTS Reconstructed image quality was equivalent to that obtained for clinical myocardial perfusion imaging. Linear regression analysis produced a correlation coefficient of 0.83 (p < 0.001) between the measured and actual values of the defect size. CONCLUSIONS These results demonstrate that myocardial perfusion can be characterized qualitatively and quantitatively in mice using pinhole SPECT. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [41] Measurement of myocardial infarct size in mice using pinhole single photon emission computed tomography
    Wu, MC
    Sievers, RE
    Gao, DW
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 365A - 365A
  • [42] Diagnostic advantage of stress computed tomography myocardial perfusion over single-photon emission computed tomography for the assessment of myocardial ischemia
    Ueki, Yasushi
    Izawa, Atsushi
    Kashiwagi, Daisuke
    Nishiyama, Shigeki
    Aso, Shinichi
    Suzuki, Chihiro
    Sakurai, Shumpei
    Oguchi, Kazuhiro
    Yazaki, Yoshikazu
    Ikeda, Uichi
    Kuwahara, Koichiro
    JOURNAL OF CARDIOLOGY, 2017, 70 (1-2) : 147 - 154
  • [43] Single-Photon Emission Computed Tomography Perfusion Imaging Is Using a "Warranty Period" Warranted?
    Kottam, Anupama
    Williams, Kim Allan, Sr.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (05) : 505 - 506
  • [44] Development of correction methods for variable pinhole single-photon emission computed tomography
    Bae, S.
    Bae, J.
    Lee, H.
    Lee, K.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [45] Single-photon emission computed tomography-computed tomography in imaging infection
    Navalkissoor, Shaunak
    Nowosinska, Ewa
    Gnanasegaran, Gopinath
    Buscombe, John R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (04) : 283 - 290
  • [46] Spatial resolution of pinhole single photon emission computed tomography imaging
    Dai Qiu-Sheng
    Qi Yu-Jin
    ACTA PHYSICA SINICA, 2010, 59 (02) : 1357 - 1365
  • [47] The effect of coronavirus disease 2019 pneumonia on myocardial ischemia detected by single-photon emission computed tomography myocardial perfusion imaging
    Bilge, Onder
    Komek, Halil
    Kepenek, Ferat
    Tastan, Ercan
    Gundogan, Cihan
    Tatli, Ismail
    ozturk, Cansu
    Akin, Halil
    Isik, Ferhat
    Kavak, Seyhmus
    Aslan, Burhan
    Akyuz, Abdurrahman
    Kanbal Cap, Nese
    Erdogan, Emrah
    NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (07) : 756 - 762
  • [48] Myocardial stunning-induced left ventricular dyssynchrony on gated single-photon emission computed tomography myocardial perfusion imaging
    Jiang, Zhixin
    Tang, Haipeng
    Shi, Jianzhou
    Zhou, Yanli
    Wang, Cheng
    Li, Dianfu
    Shan, Qijun
    Zhou, Weihua
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (08) : 725 - 731
  • [49] Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
    Tantawy, Hazem M.
    Abdelhafez, Yasser G.
    Helal, Nadia L.
    Saad, Ibrahim E.
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [50] Radiation dose reduction in myocardial perfusion imaging single-photon emission computed tomography/computed tomography using a dose-tracking software
    Serreli, Giulio
    Ruffini, Livia
    Ortenzia, Ornella
    Cidda, Carla
    Lazzara, Chiara
    Ghetti, Caterina
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (10) : 894 - 900