Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice

被引:48
|
作者
Wu, MC
Gao, DW
Sievers, RE
Lee, RJ
Hasegawa, BH
Dae, MW
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
关键词
D O I
10.1016/S0735-1097(03)00716-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement. BACKGROUND We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-resolution cardiovascular imaging of mice. In this study, we describe a protocol for myocardial perfusion imaging of mice using technetium-99m (Tc-99m)-sestamibi and demonstrate the feasibility for measurement of perfusion defect size from pinhole SPECT images. METHODS Mice were anesthetized and injected with 370 MBq (10 mCi) of Tc-99m-sestamibi. Tomographic projection images were acquired by rotating each mouse in a vertical axis in front of a stationary clinical scintillation camera equipped with a pinhole collimator. BALB/c mice (n = 15) were imaged after the permanent ligation of the left anterior descending coronary artery. The resulting defect size was measured from circumferential profiles of short-axis images. After imaging, the hearts were excised and sectioned to obtain ultra-high resolution digital autoradiographs of Tc-99m-sestamibi, from which the actual infarct size was determined. RESULTS Reconstructed image quality was equivalent to that obtained for clinical myocardial perfusion imaging. Linear regression analysis produced a correlation coefficient of 0.83 (p < 0.001) between the measured and actual values of the defect size. CONCLUSIONS These results demonstrate that myocardial perfusion can be characterized qualitatively and quantitatively in mice using pinhole SPECT. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [21] Gender differences in the application of the appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging
    Mehta, Rupa
    Agarwal, Richa
    Chandra, Sonal
    Ward, R. Parker
    Williams, Kim A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 129A - 129A
  • [22] Criteria for the addition of prone imaging to myocardial perfusion single-photon emission computed tomography for inferior wall
    Nakaya, Koji
    Onoguchi, Masahisa
    Nishimura, Yoshihiro
    Kiso, Keisuke
    Otsuka, Hideki
    Nouno, Yoshifumi
    Shibutani, Takayuki
    Yasuda, Eisuke
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (09) : 748 - 755
  • [23] Pretest models for predicting abnormal stress single-photon emission computed tomography myocardial perfusion imaging
    Megna, Rosario
    Assante, Roberta
    Zampella, Emilia
    Gaudieri, Valeria
    Nappi, Carmela
    Cuocolo, Renato
    Mannarino, Teresa
    Genova, Andrea
    Green, Roberta
    Cantoni, Valeria
    Acampa, Wanda
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (05) : 1891 - 1902
  • [24] Pretest models for predicting abnormal stress single-photon emission computed tomography myocardial perfusion imaging
    Rosario Megna
    Roberta Assante
    Emilia Zampella
    Valeria Gaudieri
    Carmela Nappi
    Renato Cuocolo
    Teresa Mannarino
    Andrea Genova
    Roberta Green
    Valeria Cantoni
    Wanda Acampa
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2021, 28 : 1891 - 1902
  • [25] Quality metrics for single-photon emission computed tomography myocardial perfusion imaging: an ASNC information statement
    Fadi G. Hage
    Andrew J. Einstein
    Karthikeyan Ananthasubramaniam
    Jamieson M. Bourque
    James Case
    E. Gordon DePuey
    Robert C. Hendel
    Milena J. Henzlova
    Nishant R. Shah
    Brian G. Abbott
    Wael Al Jaroudi
    Nathan Better
    Rami Doukky
    W. Lane Duvall
    Saurabh Malhotra
    Robert Pagnanelli
    Amalia Peix
    Eliana Reyes
    Ibrahim M. Saeed
    Rupa M. Sanghani
    Piotr J. Slomka
    Randall C. Thompson
    Vikas Veeranna
    Kim A. Williams
    David E. Winchester
    Journal of Nuclear Cardiology, 2023, 30 : 864 - 907
  • [26] Quality metrics for single-photon emission computed tomography myocardial perfusion imaging: an ASNC information statement
    Hage, Fadi G.
    Einstein, Andrew J.
    Ananthasubramaniam, Karthikeyan
    Bourque, Jamieson M.
    Case, James
    DePuey, E. Gordon
    Hendel, Robert C.
    Henzlova, Milena J.
    Shah, Nishant R.
    Abbott, Brian G.
    Al Jaroudi, Wael
    Better, Nathan
    Doukky, Rami
    Duvall, W. Lane
    Malhotra, Saurabh
    Pagnanelli, Robert
    Peix, Amalia
    Reyes, Eliana
    Saeed, Ibrahim M.
    Sanghani, Rupa M.
    Slomka, Piotr J.
    Thompson, Randall C.
    Veeranna, Vikas
    Williams, Kim A. Sr Sr
    Winchester, David E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (02) : 864 - 907
  • [27] Impact of Appropriate Use on the Prognostic Value of Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Doukky, Rami
    Hayes, Kathleen
    Frogge, Nathan
    Balakrishnan, Gautam
    Dontaraju, Venkata Satish
    Rangel, Maria O.
    Golzar, Yasmeen
    Garcia-Sayan, Enrique
    Hendel, Robert C.
    CIRCULATION, 2013, 128 (15) : 1634 - 1643
  • [28] ASSESSMENT OF MYOCARDIAL PERFUSION WITH SINGLE-PHOTON EMISSION TOMOGRAPHY
    MOHAMADIYEH, M
    ARAFA, M
    ELDESOUKI, M
    ANNALS OF SAUDI MEDICINE, 1994, 14 (02) : 97 - 101
  • [29] Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction
    Plachcinska, Anna
    Wlodarczyk, Michal
    Kovacevic-Kusmierek, Katarzyna
    Bienkiewicz, Malgorzata
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Kasprzak, Jaroslaw D.
    Peruga, Jan Z.
    Kusmierek, Jacek
    KARDIOLOGIA POLSKA, 2016, 74 (01) : 32 - 39
  • [30] Mathematical Modeling of Myocardial Perfusion Diagnosed by the Method of Single-Photon Emission Computed Tomography
    Kolinko, I. P.
    Denisova, N. V.
    Ansheles, A. A.
    TECHNICAL PHYSICS, 2020, 65 (09) : 1436 - 1441