Influence of the Realistic Artery Geometry Parameters on a Coronary Stent Fatigue Life

被引:4
|
作者
Cui, Xinyang [1 ]
Ren, Qingshuai [1 ,2 ]
Li, Gaoyang [1 ]
Li, Zihao [1 ]
Qiao, Aike [1 ]
机构
[1] Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing, Peoples R China
[2] Chinese Acad Sci, Inst Mech, 15 BeiSiHuan West Rd, Beijing, Peoples R China
基金
北京市自然科学基金;
关键词
Biomechanics; artery geometry parameters; fatigue life prediction; PERIPHERAL STENTS; FRACTURE; PREDICTION; BEHAVIOR; PATIENT; DESIGN;
D O I
10.1142/S0219876218420069
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The stents' adaptability and safety in realistic and idealized stenotic coronary model were compared to investigate the influence of artery geometry parameter on stent fatigue life. The stents' fatigue resistance ability was calculated using Goodman diagram, and the cycle to failure, the fatigue life, and the fatigue safety factor (FSF) were analyzed. Although the peak top of the von Mises stress was located at the bending area of crowns, the stress distributions were different in the two models. Considering the safety and accuracy, it is necessary to use a realistic geometric model to calculate the stent fatigue performance.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Simulation of stent deployment in a realistic human coronary artery
    Gijsen, Frank J. H.
    Migliavacca, Francesco
    Schievano, Silvia
    Socci, Laura
    Petrini, Lorenza
    Thury, Attila
    Wentzel, Jolanda J.
    van der Steen, Anton F. W.
    Serruys, Patrick W. S.
    Dubini, Gabriele
    BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
  • [2] Simulation of stent deployment in a realistic human coronary artery
    Frank JH Gijsen
    Francesco Migliavacca
    Silvia Schievano
    Laura Socci
    Lorenza Petrini
    Attila Thury
    Jolanda J Wentzel
    Anton FW van der Steen
    Patrick WS Serruys
    Gabriele Dubini
    BioMedical Engineering OnLine, 7
  • [3] Contrast Agent Bolus Dispersion in a Realistic Coronary Artery Geometry: Influence of Outlet Boundary Conditions
    Karsten Sommer
    Regine Schmidt
    Dirk Graafen
    Hanns-Christian Breit
    Laura M. Schreiber
    Annals of Biomedical Engineering, 2014, 42 : 787 - 796
  • [4] Contrast Agent Bolus Dispersion in a Realistic Coronary Artery Geometry: Influence of Outlet Boundary Conditions
    Sommer, Karsten
    Schmidt, Regine
    Graafen, Dirk
    Breit, Hanns-Christian
    Schreiber, Laura M.
    ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (04) : 787 - 796
  • [5] Influence of stenosis on hemodynamic parameters in the realistic left coronary artery under hyperemic conditions
    Kamangar, Sarfaraz
    Badruddin, Irfan Anjum
    Badarudin, A.
    Nik-Ghazali, N.
    Govindaraju, Kalimuthu
    Ahmed, N. J. Salman
    Khan, T. M. Yunus
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (04) : 365 - 372
  • [6] Fatigue life analysis and experimental verification of coronary stent
    Jianjun Li
    Qiyi Luo
    Zhiyong Xie
    Yu Li
    Yanjun Zeng
    Heart and Vessels, 2010, 25 : 333 - 337
  • [7] Fatigue life analysis and experimental verification of coronary stent
    Li, Jianjun
    Luo, Qiyi
    Xie, Zhiyong
    Li, Yu
    Zeng, Yanjun
    HEART AND VESSELS, 2010, 25 (04) : 333 - 337
  • [8] EFFECT OF STENT DESIGN PARAMETERS ON CORONARY ARTERY FLOW
    Karri, Satyaprakash
    Peter, Stephen
    Vlachos, Pavlos P.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 67 - 68
  • [9] Finite Element Analysis of Stent expansion: Influence of Stent Geometry on Performance Parameters
    Gomes, I. V.
    Puga, H.
    Alves, J. L.
    Claro, J. C. P.
    2017 IEEE 5TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2017,
  • [10] Fatigue life analysis of coronary stent by finite element analysis
    Li, Jian-Jun
    Luo, Qi-Yi
    Xie, Zhi-Yong
    Li, Yu
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2010, 25 (01): : 68 - 73