On determining dead layer and detector thicknesses for a position-sensitive silicon detector

被引:15
|
作者
Manfredi, J. [1 ,2 ]
Lee, Jenny [3 ]
Lynch, W. G. [1 ,2 ]
Niu, C. Y. [1 ,2 ,4 ,5 ]
Tsang, M. B. [1 ,2 ]
Anderson, C. [1 ,2 ]
Barney, J. [1 ,2 ]
Brown, K. W. [1 ,2 ]
Chajecki, Z. [6 ]
Chan, K. P. [1 ,2 ,7 ]
Chen, G. [6 ]
Estee, J. [1 ,2 ]
Li, Z. [4 ,5 ]
Pruitt, C. [8 ]
Rogers, A. M. [9 ]
Sanetullaev, A. [1 ,2 ]
Setiawan, H. [1 ,2 ]
Showalter, R. [1 ,2 ]
Tsang, C. Y. [1 ,2 ]
Winkelbauer, J. R. [1 ,2 ]
Xiao, Z. [10 ]
Xu, Z. [3 ]
机构
[1] Michigan State Univ, NSCL, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[3] Univ Hong Kong, Dept Phys, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
[4] Peking Univ, Sch Phys, Beijing 100871, Peoples R China
[5] Peking Univ, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[6] Western Michigan Univ, Dept Phys, Kalamazoo, MI 49008 USA
[7] Chinese Univ Hong Kong, Dept Phys, Shatin, Hong Kong, Peoples R China
[8] Washington Univ, Dept Chem, St Louis, MO 63130 USA
[9] Univ Massachusetts Lowell, Dept Phys, Lowell, MA 01854 USA
[10] Tsinghua Univ, Dept Phys, Beijing 100084, Peoples R China
基金
美国国家科学基金会;
关键词
Silicon detectors; Dead layer; Pin source; Alpha source calibration; Si-CsI calibration; IDENTIFICATION; RESOLUTION; ARRAY;
D O I
10.1016/j.nima.2017.12.082
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E'' detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted from a(212)Pb pin source placed close to the detector surface. This procedure also allows for energy calibrations of the E detectors, which are otherwise inaccessible for alpha source calibration as each one is sandwiched between two other detectors. The E detector thickness is obtained from a combination of elastically scattered protons and an energy-loss calculation method. Results from these analyses agree with values provided by the manufacturer. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 50 条
  • [41] POSITION-SENSITIVE DELTA-E DETECTOR
    BENGIS, DVH
    SEALOCK, RM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 374 - 378
  • [42] Study of a position-sensitive scintillator neutron detector
    唐彬
    孙志嘉
    张强
    杨振
    许虹
    杨桂安
    王艳凤
    吴冲
    陈元柏
    杨雷
    Chinese Physics C, 2012, 36 (11) : 1089 - 1094
  • [43] A position-sensitive detector with lithium glass and MaPMT
    付在伟
    贾茹
    衡月昆
    祁鸣
    黄长浩
    刘术林
    钱森
    李绍莉
    陈晓辉
    刘曙东
    雷祥翠
    黄国瑞
    Chinese Physics C, 2012, 36 (11) : 1095 - 1100
  • [44] RADIAL POSITION-SENSITIVE SEMICONDUCTOR DETECTOR.
    Amov, B.
    Dzhakov, A.
    Osipenko, B.P.
    Pentsya, E.
    Sandukovskii, V.G.
    Instruments and experimental techniques New York, 1985, 28 (3 pt 1): : 561 - 563
  • [45] Nanoelectromechanical Position-Sensitive Detector with Picometer Resolution
    Chien, Miao-Hsuan
    Steurer, Johannes
    Sadeghi, Pedram
    Cazier, Nicolas
    Schmid, Silvan
    ACS PHOTONICS, 2020, 7 (08): : 2197 - 2203
  • [46] A NEUTRON DIFFRACTOMETER WITH A LINEAR POSITION-SENSITIVE DETECTOR
    PARANJPE, SK
    DANDE, YD
    PRAMANA, 1989, 32 (06) : 793 - 800
  • [47] A GUINIER DIFFRACTOMETER WITH A SCANNING POSITION-SENSITIVE DETECTOR
    GOBEL, HE
    ADVANCES IN X-RAY ANALYSIS, 1982, 25 : 315 - 324
  • [48] A position-sensitive detector with lithium glass and MaPMT
    Fu Zai-Wei
    Jia Ru
    Heng Yue-Kun
    Qi Ming
    Huang Chang-Hao
    Liu Shu-Lin
    Qian Sen
    Li Shao-Li
    Chen Xiao-Hui
    Liu Shu-Dong
    Lei Xiang-Cui
    Huang Guo-Rui
    CHINESE PHYSICS C, 2012, 36 (11) : 1095 - 1100
  • [49] A LARGE AREA POSITION-SENSITIVE NEUTRON DETECTOR
    BERLINER, R
    MILDNER, DFR
    PRINGLE, OA
    KING, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 481 - 495
  • [50] POSITION-SENSITIVE X-RAY-DETECTOR
    DUVAL, BP
    BARTH, J
    DESLATTES, RD
    HENINS, A
    LUTHER, GG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 274 - 278