Deep learning-based GTV contouring modeling inter- and intra-observer variability in sarcomas

被引:8
|
作者
Marin, Thibault [1 ,3 ]
Zhuo, Yue [1 ,3 ]
Lahoud, Rita Maria [1 ,3 ]
Tian, Fei [1 ,3 ]
Ma, Xiaoyue [1 ,3 ]
Xing, Fangxu [1 ,3 ]
Moteabbed, Maryam [1 ,2 ,3 ]
Liu, Xiaofeng [1 ,3 ]
Grogg, Kira [1 ,3 ]
Shusharina, Nadya [2 ,3 ]
Woo, Jonghye [1 ,3 ]
Lim, Ruth [1 ,3 ]
Ma, Chao [1 ,3 ]
Chen, Yen-Lin E. [1 ,2 ,3 ]
El Fakhri, Georges [1 ,3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Gordon Ctr Med Imaging, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
Sarcoma; Radiotherapy planning; Computer-assisted; Deep learning; DELINEATION;
D O I
10.1016/j.radonc.2021.09.034
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The delineation of the gross tumor volume (GTV) is a critical step for radiation therapy treatment planning. The delineation procedure is typically performed manually which exposes two major issues: cost and reproducibility. Delineation is a time-consuming process that is subject to inter- and intra-observer variability. While methods have been proposed to predict GTV contours, typical approaches ignore variability and therefore fail to utilize the valuable confidence information offered by multiple contours. Materials and methods: In this work we propose an automatic GTV contouring method for soft-tissue sarcomas from X-ray computed tomography (CT) images, using deep learning by integrating inter- and intra-observer variability in the learned model. Sixty-eight patients with soft tissue and bone sarcomas were considered in this evaluation, all underwent pre-operative CT imaging used to perform GTV delineation. Four radiation oncologists and radiologists performed three contouring trials each for all patients. We quantify variability by defining confidence levels based on the frequency of inclusion of a given voxel into the GTV and use a deep convolutional neural network to learn GTV confidence maps. Results: Results were compared to confidence maps from the four readers as well as ground-truth consensus contours established jointly by all readers. The resulting continuous Dice score between predicted and true confidence maps was 87% and the Hausdorff distance was 14 mm. Conclusion: Results demonstrate the ability of the proposed method to predict accurate contours while utilizing variability and as such it can be used to improve clinical workflow. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [21] Effects of inter- and intra-observer variability on echocardiographic measurements in awake cats
    Chetboul, V
    Concordet, D
    Pouchelon, JL
    Athanassiadis, N
    Muller, C
    Benigni, L
    Munari, AC
    Lefebvre, HP
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2003, 50 (06): : 326 - 331
  • [22] Inter- and intra-observer variation in phytolith morphometry
    Out, Welmoed A.
    Evett, Rand
    Hoskova, Kristyna
    Power, Robert C.
    Ruiz-Perez, Javier
    Tromp, Monica
    Vrydaghs, Luc
    Wade, Kali
    Hasler, Mario
    ANNALS OF BOTANY, 2024,
  • [23] Reducing inter-observer and intra-observer variability of embryo quality assessment using deep learning
    Sais, E.
    Mayeur, A.
    Binois, O.
    Hesters, L.
    Puy, V.
    Fossard, C.
    Filali, M.
    Vandame, J.
    Poulain, M.
    Frydman, N.
    HUMAN REPRODUCTION, 2022, 37
  • [24] Inter-observer and intra-observer variability in hepatology
    Winkfield, B
    Aubé, C
    Burtin, P
    Calès, P
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2003, 15 (09) : 959 - 966
  • [25] Inter- and intra-observer variability in the assessment of atelectasis and consolidation in neonatal chest radiographs
    Frank H. Bloomfield
    Rita L. Teele
    Maurice Voss
    David B. Knight
    Jane E. Harding
    Pediatric Radiology, 1999, 29 : 459 - 462
  • [26] Inter- and intra-observer variability in the assessment of atelectasis and consolidation in neonatal chest radiographs
    Bloomfield, FH
    Teele, RL
    Voss, M
    Knight, DB
    Harding, JE
    PEDIATRIC RADIOLOGY, 1999, 29 (06) : 459 - 462
  • [27] Sanders classification of fractures of the os calcis - An analysis of inter- and intra-observer variability
    Bhattacharya, R
    Vassan, UT
    Finn, P
    Port, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02): : 205 - 208
  • [28] Inter- and intra-observer variability in the IGRT cut image of Prostate by in room CT
    Alheit, H.
    Alheit, D.
    Schreiber, M.
    Beier, M.
    Herrmann, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 55 - 56
  • [29] Inter- and intra-observer variability of manual cough counting in cough challenge testing
    Polley, L.
    Cardwell, C.
    Butler, C.
    Magee, N.
    Macmahon, J.
    Costello, R.
    Mcgarvey, L.
    THORAX, 2007, 62 : A107 - A108
  • [30] INTER- AND INTRA-OBSERVER AGREEMENT IN THE MILCH AND WEISS SYSTEMS
    Charles Lozoya, Sergio
    Trevino Baez, Joaquin Dario
    Rangel Flores, Jesus Maria
    Brizuela Ventura, Jesus Miguel
    Araiza Topete, Omar
    Alcazar Juarez, Andrea
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 218 - 221