Accuracy of a 3D fluoroscopic navigation system using a flat-panel detector-equipped C-arm

被引:12
|
作者
Takao, Masaki [1 ]
Yabuta, Kentaro [1 ]
Nishii, Takashi
Sakai, Takashi [1 ]
Sugano, Nobuhiko
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Sugery, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
3D fluoroscopic navigation; flat-panel detector; accuracy; image distortion; SCREW PLACEMENT; CLINICAL ACCURACY; SURGERY; EXCISION; ISO-C-3D;
D O I
10.3109/10929088.2011.602117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of this study was to evaluate the accuracy of a novel 3-dimensional (3D) fluoroscopic navigation system using a flat-panel detector-equipped C-arm, focusing on the influence of the distance from the center of fluoroscopic imaging on navigation accuracy. Materials and Methods: A geometric phantom was made using a Styrofoam cube with 25 markers, each consisting of a metal ball 1.5 mm in diameter, fixed in a cross arrangement at 1-cm intervals. Hip joint surgery was simulated using a set of dry pelvic and femoral bones. A total of eight markers were fixed to the acetabulum and proximal femur. Results: In the geometric phantom study, mean target registration error (TRE) was 0.7 mm (range: 0.1-1.5). The TRE of markers located at 5 cm from the imaging center was significantly higher than the TRE of markers located at 1 and 2 cm. However, the TRE was <1 mm in 90% of the overall trials and <1.5 mm in 100%. In the dry bone study, the mean TRE was 0.9 mm (range: 0.7-1.5) over the acetabulum and 1.0 mm (range: 0.5-1.4) over the femur. No significant difference in TRE was seen between the acetabulum and proximal femur. Conclusion: The accuracy of this novel 3D fluoroscopic navigation system was considered acceptable for clinical application. A 3D C-arm equipped with a flat-panel detector could increase the feasibility of 3D fluoroscopic navigation by reducing the effects of image distortion on navigation accuracy.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 50 条
  • [1] Radiation exposure of a mobile 3D C-arm with large flat-panel detector for intraoperative imaging and navigation - an experimental study using an anthropomorphic Alderson phantom
    Yashar Naseri
    Ulrich Hubbe
    Christoph Scholz
    Johannes Brönner
    Marie T. Krüger
    Jan-Helge Klingler
    [J]. BMC Medical Imaging, 20
  • [2] Radiation exposure of a mobile 3D C-arm with large flat-panel detector for intraoperative imaging and navigation-an experimental study using an anthropomorphic Alderson phantom
    Naseri, Yashar
    Hubbe, Ulrich
    Scholz, Christoph
    Broenner, Johannes
    Krueger, Marie T.
    Klingler, Jan-Helge
    [J]. BMC MEDICAL IMAGING, 2020, 20 (01)
  • [3] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Martin Wiewiorski
    Martin Thanh Long Takes
    Victor Valderrabano
    Augustinus Ludwig Jacob
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 177 - 180
  • [4] Percutaneous foot joint needle placement using a C-arm flat-panel detector CT
    Wiewiorski, Martin
    Takes, Martin Thanh Long
    Valderrabano, Victor
    Jacob, Augustinus Ludwig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 177 - 180
  • [5] Reliability and Usefulness of Intraoperative 3-Dimensional Imaging by Mobile C-Arm With Flat-Panel Detector
    Fujimori, Takahito
    Iwasaki, Motoki
    Nagamoto, Yukitaka
    Kashii, Masafumi
    Takao, Masaki
    Sugiura, Tsuyoshi
    Yoshikawa, Hideki
    [J]. CLINICAL SPINE SURGERY, 2017, 30 (01): : E64 - E75
  • [6] Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector
    Cha, Bo Kyung
    Jeon, Seongchae
    Seo, Chang-Woo
    Back, Jongduck
    Choi, Shinkook
    Lee, Changwoo
    Ahn, Miseob
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 343 - 349
  • [7] Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector
    Cha, Bo Kyung
    Seo, Chang-Woo
    Yang, Keedong
    Jeon, Seongchae
    Huh, Young
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 565 - 569
  • [8] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    [J]. DIAGNOSTICS, 2023, 13 (01)
  • [9] Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome
    Sung Eun Kang
    Joon Woo Lee
    Joo Hyung Kim
    Kun Woo Park
    Jin S. Yeom
    Heung Sik Kang
    [J]. Skeletal Radiology, 2011, 40 : 453 - 460
  • [10] Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome
    Kang, Sung Eun
    Lee, Joon Woo
    Kim, Joo Hyung
    Park, Kun Woo
    Yeom, Jin S.
    Kang, Heung Sik
    [J]. SKELETAL RADIOLOGY, 2011, 40 (04) : 453 - 460