Validation of STR typing by capillary electrophoresis

被引:0
|
作者
Moretti, TR [1 ]
Baumstark, AL
Defenbaugh, DA
Keys, KM
Brown, AL
Budowle, B
机构
[1] Fed Bur Invest Acad, Forens Sci Res Unit, FBI Lab, Sci Anal Sect, Quantico, VA 22135 USA
[2] FBI Lab, DNA Anal Unit 1, Sci Anal Sect, Washington, DC USA
关键词
forensic science; DNA typing; polymerase chain reaction; short tandem repeats; capillary electrophoresis; fluorescence; validation;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised greater than or equal to5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType (TM) PM+DQAI, and/or DIS80) were amplified using AmpFlSTR((R)) Profiler Plus (TM) and COfiler (TM) and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects pr victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.
引用
收藏
页码:661 / 676
页数:16
相关论文
共 50 条
  • [41] NGS library validation using automated capillary gel electrophoresis
    1600, International Scientific Communications Inc. (49):
  • [42] Validation of capillary electrophoresis in the analysis of ewe's milk casein
    Izco, JM
    Ordóñez, AI
    Torre, P
    Barcina, Y
    JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 239 - 246
  • [43] Validation of capillary electrophoresis methods applied to pharmaceutical compound analysis
    Fabre, H
    ANALUSIS, 1999, 27 (02) : 155 - 160
  • [44] Development and validation of capillary electrophoresis methods for pharmaceutical dissolution assays
    Lucangioli, SE
    Rodriguez, VG
    Otero, GCF
    Vizioli, NM
    Carducci, CN
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1997, 4 (01) : 27 - 31
  • [45] Capillary Electrophoresis Method Validation for Organic Acids Assessment in Probiotics
    Gatea, Florentina
    Teodor, Eugenia D.
    Paun, Gabriela
    Matei, Alina O.
    Radu, Gabriel L.
    FOOD ANALYTICAL METHODS, 2015, 8 (05) : 1335 - 1340
  • [46] Screening of Hemoglobinopathies: A Validation Study of Capillary Zone Electrophoresis With HPLC
    Tholpady, Ashok
    Bai, Yu
    Nedelcu, Elena G.
    Nguyen, Juliette
    Risin, Semyon A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A290 - A290
  • [47] Validation of analytical capillary electrophoresis methods for use in a regulated environment
    Wielgos, T
    Turner, P
    Havel, K
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1997, 4 (06) : 273 - 278
  • [48] AN OVERVIEW OF METHOD VALIDATION AND SYSTEM SUITABILITY ASPECTS IN CAPILLARY ELECTROPHORESIS
    ALTRIA, KD
    RUDD, DR
    CHROMATOGRAPHIA, 1995, 41 (5-6) : 325 - 331
  • [49] Validation and quality control of methylmercury determinations by means of capillary electrophoresis
    Diaz, AMC
    LorenzoFerreira, RA
    CelaTorrijos, R
    MIKROCHIMICA ACTA, 1996, 123 (1-4) : 73 - 86
  • [50] NGS Library Validation Using Automated Capillary Gel Electrophoresis
    Chang, Jemmie
    Lin, Alice
    Tsai, Eric
    Amirkhanian, Varouj
    AMERICAN LABORATORY, 2017, 49 (02) : 38 - 39