Validation of STR typing by capillary electrophoresis

被引:0
|
作者
Moretti, TR [1 ]
Baumstark, AL
Defenbaugh, DA
Keys, KM
Brown, AL
Budowle, B
机构
[1] Fed Bur Invest Acad, Forens Sci Res Unit, FBI Lab, Sci Anal Sect, Quantico, VA 22135 USA
[2] FBI Lab, DNA Anal Unit 1, Sci Anal Sect, Washington, DC USA
关键词
forensic science; DNA typing; polymerase chain reaction; short tandem repeats; capillary electrophoresis; fluorescence; validation;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
With the use of capillary electrophoresis (CE), high-resolution electrophoretic separation of short tandem repeat (STR) loci can be achieved in a semiautomated fashion. Laser-induced detection of fluorescently labeled PCR products and multicolor analysis enable the rapid generation of multilocus DNA profiles. In this study, conditions for typing PCR-amplified STR loci by capillary electrophoresis were investigated using the ABI Prism 310 Genetic Analyzer (Applied Biosystems). An internal size standard was used with each run to effectively normalize mobility differences among injections. Alleles were designated by comparison to allelic ladders that were run with each sample set. Multiple runs of allelic ladders and of amplified samples demonstrate that allele sizes were reproducible, with standard deviations typically less than 0.12 bases for fragments up to 317 bases in length (largest allele analyzed) separated in a 47 cm capillary. Therefore, 99.7% of all alleles that are the same length should fall within the measurement error window of +/- 0.36 bases. Microvariants of the tetranucleotide repeats were also accurately typed by the analytical software. Alleles differing in size by one base could be resolved in two-donor DNA mixtures in which the minor component comprised greater than or equal to5% of the total DNA. Furthermore, the quantitative data format (i.e., peak amplitude) can in some instances assist in determining individual STR profiles in mixed samples. DNA samples from previously typed cases (typed for RFLP, AmpliType (TM) PM+DQAI, and/or DIS80) were amplified using AmpFlSTR((R)) Profiler Plus (TM) and COfiler (TM) and were evaluated using the ABI Prism 310. Most samples yielded typable results. Compared with previously determined results for other loci, there were no discrepancies as to the inclusion or exclusion of suspects pr victims. CE thus provides efficient separation, resolution, sensitivity and precision, and the analytical software provides reliable genotyping of STR loci. The analytical conditions described are suitable for typing samples such as reference and evidentiary samples from forensic casework.
引用
收藏
页码:661 / 676
页数:16
相关论文
共 50 条
  • [21] Development and validation of a new STR 25-plex typing system
    Zhang, Suhua
    Bian, Yingnan
    Tian, Huaizhou
    Wang, Zheng
    Hua, Zhen
    Li, Chengtao
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2015, 17 : 61 - 69
  • [22] Validation of a neural network approach for STR typing to replace human reading
    Volgin, Luke
    Taylor, Duncan
    Bright, Jo-Anne
    Lin, Meng-Han
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2021, 55
  • [23] PCR typing of FXIIIB short tandem repeat polymorphism by capillary electrophoresis
    Pei, L
    Deng, H
    Zhang, LJ
    Jiang, CT
    Zhao, XC
    Chang, CQ
    Wang, J
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2002, 29 (03) : 460 - 463
  • [24] Rapid ink typing with capillary electrophoresis and UV-Vis spectroscopy
    Grimes, Courtney
    Huang, Ling
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [25] DNA typing of fingerprints using capillary electrophoresis: Effect of dactyloscopic powders
    Van Hoofstat, DEO
    Deforce, DLD
    De Pauw, IPH
    Van den Eeckhout, EG
    ELECTROPHORESIS, 1999, 20 (14) : 2870 - 2876
  • [26] Free open source software for internal validation of forensic STR typing kits
    Hansson, Oskar
    Gill, Peter
    FORENSIC SCIENCE INTERNATIONAL GENETICS SUPPLEMENT SERIES, 2013, 4 (01) : E300 - E301
  • [27] DEVELOPMENT AND VALIDATION OF CAPILLARY ELECTROPHORESIS ASSAY FOR RIBONUCLEASE-A
    NELLORE, R
    BHAGAT, HR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (11) : 1363 - 1367
  • [28] Analysis of doxycycline by capillary electrophoresis - Method development and validation
    Gil, EC
    Van Schepdael, A
    Roets, E
    Hoogmartens, J
    JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) : 43 - 49
  • [29] QUANTITATIVE APPLICATIONS AND VALIDATION OF THE RESOLUTION OF ENANTIOMERS BY CAPILLARY ELECTROPHORESIS
    ALTRIA, KD
    GOODALL, DM
    ROGAN, MM
    ELECTROPHORESIS, 1994, 15 (06) : 824 - 827
  • [30] Development and validation of a quantitative assay for raloxifene by capillary electrophoresis
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Sanz, A
    Bravo, E
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 891 - 897