Effects of pipeline distance, injectivity and capacity on CO2 pipeline and storage site selection

被引:11
|
作者
Wang, Z. [1 ,2 ]
Weihs, G. A. Fimbres [1 ,2 ,3 ]
Neal, P. R. [1 ,4 ]
Wiley, D. E. [1 ,2 ,5 ]
机构
[1] CO2CRC Ltd, Melbourne, Vic, Australia
[2] UNSW Sydney, UNSW Australia, Sch Chem Engn, Sydney, NSW 2052, Australia
[3] Inst Tecnol Sonora, Catedras CONACYT, Obregon 85130, Sonora, Mexico
[4] UNSW Sydney, UNSW Australia, Sch Petr Engn, Sydney, NSW 2052, Australia
[5] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
Carbon capture and storage; Pipeline optimisation; Sink capacity; Injectivity; CARBON CAPTURE; TRANSPORT; CCS; DESIGN; SCALE; COST;
D O I
10.1016/j.ijggc.2016.05.006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Optimising CO2 transport and injection is a challenging issue in Carbon Capture and Storage (CCS), not only because of the complexity of the problem, but also because of timing effects when introducing new sources and/or sinks into the CO2 transport infrastructure. In particular, the effects of storage capacity, injection site location and reservoir properties can propagate to capture and transport costs, affecting the design of the CO2 pipelines. For example, if an injection site does not have enough capacity to store the total amount of CO2 from a capture project, decision makers would need to consider whether to use a larger capacity site, or use the site with small capacity and later switch to a larger capacity site or use both sites. This paper considers the effects of storage capacity, injectivity and distance to source of two sinks on optimal CO2 transport infrastructure design and a static supply of CO2. Optimal pipeline configurations and sink selection were determined under different combinations of CO2 flow rate, pipeline length and storage site properties. In one scenario, two sinks both have infinite capacity but different injectivities and distances to the emission source. In the other scenario, one sink is relatively small but has a better injectivity or proximity to the emission source. A decision tree approach was developed to provide a quick method for high-level sink selection and pipeline routing for the two scenarios based on the key project parameters including sink capacity, injectivities, pipeline distances and well cost. The scenarios where the decision trees may be useful for simplifying the design of large-scale CO2 pipeline networks have also been analysed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 50 条
  • [31] Assessment of Factors Influencing CO2 Storage Capacity and Injectivity in Eastern US Gas Shales
    Godec, Michael
    Koperna, George
    Petrusak, Robin
    Oudinot, Anne
    GHGT-11, 2013, 37 : 6644 - 6655
  • [32] Effects of Anisotropy and CO2 Wettability on CO2 Storage Capacity in Sandstone
    Song, Jun Young
    Jeong, Yeon Jong
    Yun, Tae Sup
    GEOFLUIDS, 2022, 2022
  • [33] Correlative comparison of gas CO2 pipeline transportation and natural gas pipeline transportation
    Zhang, Yindi (zhangyindihust@foxmail.com), 1600, AMSE Press, 16 Avenue Grauge Blanche, Tassin-la-Demi-Lune, 69160, France (86):
  • [34] Experimental Study on Corrosion Characteristics of CO2 Pipeline for Offshore Transport and Geological Storage
    Cho, Meang-Ik
    Huh, Cheol
    Kang, Seong-Gil
    Baek, Jong-Hwa
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 2442 - 2447
  • [35] The Effect of CO2 Purity on the Development of Pipeline Networks for Carbon Capture and Storage Schemes
    Wetenhall, B.
    Race, J. M.
    Downie, M. J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 30 : 197 - 211
  • [36] CO2 injection and storage-coupling pipeline network, wellbore, and reservoir models
    Senel, Ozgur
    Harichandran, Arutchelvi
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 2348 - 2355
  • [37] Long-term thermal effects on injectivity evolution during CO2 storage
    Vilarrasa, Victor
    Rinaldi, Antonio P.
    Rutqvist, Jonny
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2017, 64 : 314 - 322
  • [38] PROGRAM CALCULATES PIPELINE-STORAGE CAPACITY
    ELGASSIER, MM
    OIL & GAS JOURNAL, 1989, 87 (46) : 94 - 96
  • [39] Program calculates pipeline-storage capacity
    El-Gassier, M.M., 1600, (87):
  • [40] Illustrating the estimation of CO2 storage capacity for a hypothetical injection site
    Allinson, W. G.
    Hou, W.
    Azizi, E.
    Neal, P. R.
    Cinar, Y.
    Kaldi, J.
    Paterson, L.
    GHGT-11, 2013, 37 : 5160 - 5165