Experimental Study on Mechanical Properties of Rebar in Steel Half-Grouted Sleeve Connections with Construction Defects

被引:1
|
作者
Chen, Dong [1 ]
Zhang, Zhiyong [1 ]
Liu, Xiaozhen [2 ]
Wang, Qiong [3 ]
Zhao, Baojun [3 ]
Ren, Gang [3 ]
Wang, Changjun [4 ]
机构
[1] Anhui Jianzhu Univ, BIM Engn Ctr Anhui Prov, Hefei 230601, Peoples R China
[2] Anhui Jianzhu Univ, Hefei 230601, Peoples R China
[3] China State Construct HaiLong Technol Co Ltd, Shenzhen 518000, Guangdong, Peoples R China
[4] Beijing Bldg Res Inst Corp Ltd CSCEC, Beijing 100076, Peoples R China
关键词
BOND BEHAVIOR; SPLICE SLEEVE;
D O I
10.1155/2022/9379135
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A prefabricated concrete structure is a building structure designed for sustainability and low comprehensive carbon emission. The grouted sleeve splice is a major connection method for prefabricated concrete structures. However, construction defects occur easily in the grouted sleeve splice connection at construction sites because of complex construction environments and the high connection accuracy. To determine the influence of rebar in steel half-grouted sleeve connections with construction defects, investigations were conducted using four different test groups (rebar offset, rebar bended, insufficient fluidity of grout, and control group). The load-displacement curve and load-stress curve were analyzed on 24 different specimens through uniaxial tension experiments. The experimental results showed that rebar fracture was the failure of specimens. The load-displacement curves consisted of elastic, yield, strength, and tight stages. The curves were similar to rebar under uniaxial tension, except for the rebar bended group. The axial stress and circumferential stress on the sleeve surface consistently followed a linear response before the specimen yield, whereas the axial stress and circumferential stress showed a rebound response after the specimen yielded. Different finite element models were established based on the different defects. Compared with the experimental results, the finite element analysis results coincided with those of the experimental results, and the errors were within 8% to evaluate the performance of steel half-grouted sleeve connections in construction.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Study on Uniaxial Tensile Test of Half Grouted Sleeve Connection with Axial Eccentric Rebar after High Temperature
    Zhang W.
    Wang J.
    Zhao X.
    Li J.
    Lu L.
    Cao Y.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (09): : 9 - 19
  • [32] Experimental study on the mechanical properties of grouted sleeve joint with the fiber-reinforced grouting material
    Zhang, Pu
    Yu, Jixing
    Pang, Yuyang
    Fan, Jiajun
    Guo, Hui
    Pan, Zuanfeng
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [33] Experimental study on mechanical properties of polypropylene fiber grouting material and its rebar sleeve connection
    Chen M.
    Zhao L.
    Li P.
    Xu S.
    Zhang P.
    Guo H.
    Yu J.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2022, 39 (02): : 685 - 694
  • [34] Experimental and analytical study on grouted duct connections in precast concrete construction
    M. Elsayed
    M. L. Nehdi
    Materials and Structures, 2017, 50
  • [35] Experimental and analytical study on grouted duct connections in precast concrete construction
    Elsayed, M.
    Nehdi, M. L.
    MATERIALS AND STRUCTURES, 2017, 50 (04)
  • [36] Experimental study on tensile performance of defect detectable and repairable half grouted sleeve connection
    Chen X.
    Miao Q.-S.
    Yang C.-T.
    Ge D.-D.
    Liu Q.-M.
    Xie L.-L.
    Xie, Lin-Lin (xielinlin@bucea.edu.cn), 1600, Tsinghua University (37): : 199 - 207
  • [37] Experimental investigation on the horizontal impact response of precast RC bridge piers with grouted sleeve connections considering defects
    He, An
    Zheng, Dun-Cong
    Cai, Jian
    Chen, Qing-Jun
    Tang, Xu-Lin
    Ye, Jia-Bin
    ENGINEERING STRUCTURES, 2024, 316
  • [38] Experimental study on mechanical behaviors of grouted sleeve splices after high temperatures
    Xiao J.
    Liu L.
    Ding T.
    Zhang L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (11): : 99 - 107
  • [39] Grouted sleeve connections used in precast reinforced concrete construction - Experimental investigation of a column-to-column joint
    Tullini, Nerio
    Minghini, Fabio
    ENGINEERING STRUCTURES, 2016, 127 : 784 - 803
  • [40] Experimental study on seismic response of precast bridge piers with double-grouted sleeve connections
    Liu, Yang
    Li, Xinping
    Zheng, Xiaohong
    Song, Zhuo
    ENGINEERING STRUCTURES, 2020, 221 (221)