Experimental Study on Mechanical Properties of Rebar in Steel Half-Grouted Sleeve Connections with Construction Defects

被引:1
|
作者
Chen, Dong [1 ]
Zhang, Zhiyong [1 ]
Liu, Xiaozhen [2 ]
Wang, Qiong [3 ]
Zhao, Baojun [3 ]
Ren, Gang [3 ]
Wang, Changjun [4 ]
机构
[1] Anhui Jianzhu Univ, BIM Engn Ctr Anhui Prov, Hefei 230601, Peoples R China
[2] Anhui Jianzhu Univ, Hefei 230601, Peoples R China
[3] China State Construct HaiLong Technol Co Ltd, Shenzhen 518000, Guangdong, Peoples R China
[4] Beijing Bldg Res Inst Corp Ltd CSCEC, Beijing 100076, Peoples R China
关键词
BOND BEHAVIOR; SPLICE SLEEVE;
D O I
10.1155/2022/9379135
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A prefabricated concrete structure is a building structure designed for sustainability and low comprehensive carbon emission. The grouted sleeve splice is a major connection method for prefabricated concrete structures. However, construction defects occur easily in the grouted sleeve splice connection at construction sites because of complex construction environments and the high connection accuracy. To determine the influence of rebar in steel half-grouted sleeve connections with construction defects, investigations were conducted using four different test groups (rebar offset, rebar bended, insufficient fluidity of grout, and control group). The load-displacement curve and load-stress curve were analyzed on 24 different specimens through uniaxial tension experiments. The experimental results showed that rebar fracture was the failure of specimens. The load-displacement curves consisted of elastic, yield, strength, and tight stages. The curves were similar to rebar under uniaxial tension, except for the rebar bended group. The axial stress and circumferential stress on the sleeve surface consistently followed a linear response before the specimen yield, whereas the axial stress and circumferential stress showed a rebound response after the specimen yielded. Different finite element models were established based on the different defects. Compared with the experimental results, the finite element analysis results coincided with those of the experimental results, and the errors were within 8% to evaluate the performance of steel half-grouted sleeve connections in construction.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Experimental investigation on the connection performance of defect detectable and repairable half-grouted sleeve under cyclic loads
    Xie, Linlin
    Zhong, Bojian
    Chen, Xi
    Miao, Qisong
    Liu, Qianmin
    Yang, Cantian
    Wang, Xinyu
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 323
  • [22] Bond strength prediction model of defective grout materials in half-grouted sleeve connections under uniaxial and cyclic loadings
    Liu, Qizhou
    Lin, Yuhan
    Li, Jinzhou
    Yang, Chengjian
    Chen, Jingyi
    Zhang, Min
    Liu, Bing
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 352
  • [23] Post-fire tensile properties of half-grouted sleeve connection under different cooling paths
    Zhang, Wangxi
    Lv, Weilei
    Zhang, Jinyi
    He, Chao
    Deng, Xi
    Yi, Weijian
    FIRE SAFETY JOURNAL, 2019, 109
  • [24] Mechanical behavior of half-grouted sleeve connection under the coupling of sulfate erosion and dry-wet cycles
    Wang, Tongxing
    Wen, Jianian
    Hu, Menghan
    Han, Qiang
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 456
  • [25] Experimental study on post-fire performance of half grouted sleeve connection with construction defect
    Zhang, Wangxi
    Wang, Jia
    Zhang, Jinyi
    Cao, Yadong
    Qin, Peng
    Yi, Weijian
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 244
  • [26] Experimental study on axial mechanical performance of steel pipe-to-sleeve grouted connection
    Wu L.
    Su Y.
    Chen H.
    Yu H.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (11): : 191 - 199
  • [27] Numerical study on the influence of defects in grouting on the mechanical properties of a full grouted sleeve connector
    Kahama, Espoir Kulondwa
    Fuzhe, Xie
    Anglaaere, Desmond-Luke M.
    JOURNAL OF ADHESION, 2022, 98 (16): : 2550 - 2581
  • [28] Comparison of tensile mechanical properties of half grouted sleeve connection at elevated and post-elevated temperature: An experimental study
    Wang, Weichen
    Li, Jun-Hua
    Guo, Fei
    Chen, Pingjun
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 433
  • [29] Experimental investigation on the failure modes of grouted sleeve connections under thermal and mechanical loads
    Wang, Tan
    Xu, Haoming
    Yu, Min
    Xu, Lihua
    Ye, Jianqiao
    ENGINEERING FAILURE ANALYSIS, 2020, 109
  • [30] Experimental and numerical investigation on mechanical properties of grouted-sleeve splices
    Liu, Chao
    Pan, Liufeng
    Liu, Hai
    Tong, Huawei
    Yang, Yubing
    Chen, Wei
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 260