Feasibility study to use the current transformers as inductive partial discharge sensors

被引:0
|
作者
Haghjoo, Farhad [1 ]
Savaei, Ali [1 ]
机构
[1] Shahid Beheshti Univ, Abbaspour Sch Engn, Dept Elect Engn, Tehran, Iran
关键词
current transformers; inductance measurement; partial discharge measurement; power transformer insulation; condition monitoring; signal detection; electric current measurement; voltage measurement; capacitive sensors; capacitance measurement; power transformer protection; inductive partial discharge sensor; gradual insulation deterioration; high-voltage power equipment; HV power equipment; condition assessment; impulsive high-frequency PD current-voltage signal detection; electrical sensor; inductive-capacitive sensor; power frequency current transformer; HV electrical power system; medium voltage electrical power system; reversed transfer function; CT input PD pulse reconstruction; PD detection; PD measurement; CAPACITIVE COUPLERS; CABLES; LOCALIZATION; PULSES; PD;
D O I
10.1049/iet-gtd.2016.0145
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) is the most important factor in gradual insulation deterioration of high-voltage (HV) power equipment, and then PD trend monitoring is a great issue for their condition assessment. Impulsive high-frequency PD current/voltage signals can be detected by using electrical sensors, e.g. inductive/capacitive sensors. A comprehensive feasibility study is carried out to use the power frequency current transformers (CTs) that are already installed in medium voltage and HV electrical power systems instead of high-frequency CTs. To achieve this aim, frequency response of a sample protection CT is extracted experimentally and it is fitted to appropriate transfer functions to access the related frequency characteristics. Regarding improper CT frequency response and its extreme variations in different frequencies, reversed transfer function is obtained to apply to CT secondary signals for reconstructing CT input PD pulses. Two types of artificial PD pulses are examined to validate the proposed method and the experimental results show that power frequency CTs can be used for PD detection and measurement in some frequency bands.
引用
收藏
页码:3786 / 3794
页数:9
相关论文
共 50 条
  • [1] The Use of Power Frequency Current Transformers as Partial Discharge Sensors for Underground Cables
    Mohamed, F. P.
    Siew, W. H.
    Soraghan, J. J.
    Strachan, S. M.
    McWilliam, J.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 814 - 824
  • [2] Feasibility study for partial discharge detection and defective region identification in power transformers by using distributed sensors
    Mohammadi, Hasan
    Haghjoo, Farhad
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (16) : 4006 - 4023
  • [3] Partial Discharge Localization in Transformers Using UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Ao, P. L.
    Blackburn, T. R.
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 64 - 68
  • [4] Parameters of inductive sensors for partial discharge activity measurement
    Dzmura, Jaroslav
    Balogh, Jozef
    Petras, Jaroslav
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 191 - 193
  • [5] Design and testing of UHF sensors for Partial Discharge detection in transformers
    Lopez-Roldan, J.
    Tang, T.
    Gaskin, M.
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1052 - +
  • [6] Transfer function-based partial discharge localization in power transformers: A feasibility study
    Akbari, A
    Werle, P
    Borsi, H
    Gockenbach, E
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2002, 18 (05) : 22 - 32
  • [7] Use of COMTRADE Fault Current Data to Test Inductive Current Transformers
    Mingotti, Alessandro
    Peretto, Lorenzo
    Tinarelli, Roberto
    Zhang, Junhao
    [J]. 2019 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 AND INTERNET OF THINGS (METROIND4.0&IOT), 2019, : 103 - 107
  • [8] The Study of Ultraviolet Pulse for Partial Discharge of Transformers
    Tan, Wenqiang
    Huang, Wen
    Wang, Ke
    Zhang, Zhanlong
    [J]. 2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1765 - +
  • [9] Partial discharge pattern recognition of current transformers using an ENN
    Wang, MH
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 1984 - 1990
  • [10] Application of Magnetic Materials in Inductive Sensors for Partial Discharge Activity Monitoring
    Petras, J.
    Dzmura, J.
    Kurimsky, J.
    Cimbala, R.
    Kolcunova, I
    Dolnik, B.
    Zbojovsky, J.
    [J]. ACTA PHYSICA POLONICA A, 2020, 137 (05) : 714 - 716