Experimental validation of the numerical model of air, heat and moisture flow in an indoor swimming pool

被引:32
|
作者
Ciuman, Piotr [1 ]
Lipska, Barbara [1 ]
机构
[1] Silesian Tech Univ, Dept Heating Ventilat & Dust Removal Technol, Konarskiego 20, PL-44100 Gliwice, Poland
关键词
Indoor swimming pool; Ventilation; Air flow variables; Measurement; CFD prediction; Experimental validation; EVAPORATION; PREDICTION; SIMULATION; OPENFOAM;
D O I
10.1016/j.buildenv.2018.09.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor swimming pools are facilities in which a ventilation system has a vital impact on the proper operation of the building, as well as the users' comfort, operating costs and the safety of the structure. The major problem in ensuring appropriate thermal-moisture conditions is the removal of moisture that is mainly gained from the surface of the water in the pool's basin. The aim of this paper was to experimentally identify the physical phenomena occurring in the actual indoor swimming pool and to evaluate whether the numerical model of the facility, developed with the use of Ansys CFX 14.5 software, correctly mapped these phenomena and how it should be improved in this field. Results of the experimental research of the air variables, carried out in various periods of the year, were used to identify the changes in the thermal-moisture conditions and to prepare boundary conditions for the numerical calculations, as well as to validate these simulations experimentally. The numerical model was improved with the use of the authors' own method of modelling moisture emission from the surface of the water. It was based on the implementation of literature formulas for calculating the value of this parameter in the software. The validation encompassed the indoor airflow pattern and the distribution of the air flow variables above the surface of the water and around the pool's basin. The improved numerical model was able to reproduce the actual conditions in the indoor swimming pool with good concurrence of the experimental and predicted values.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Swimming pools as heat sinks for air conditioners: Model design and experimental validation for natural thermal behavior of the pool
    Woolley, Jonathan
    Harrington, Curtis
    Modera, Mark
    BUILDING AND ENVIRONMENT, 2011, 46 (01) : 187 - 195
  • [2] Chlorine concentrations in the air of indoor swimming pools and their effects on swimming pool workers
    Fernandez-Luna, Alvaro
    Burillo, Pablo
    Luis Felipe, Jose
    Gallardo, Leonor
    Manuel Tamaral, Francisco
    GACETA SANITARIA, 2013, 27 (05) : 411 - 417
  • [3] Numerical calibration and experimental validation of a PCM-Air heat exchanger model
    Stathopoulos, N.
    El Mankibi, M.
    Santamouris, Mattheos
    APPLIED THERMAL ENGINEERING, 2017, 114 : 1064 - 1072
  • [4] A MODEL OF THE ENERGY FLUXES IN A SOLAR HEATED SWIMMING POOL AND ITS EXPERIMENTAL VALIDATION
    RAKOPOULOS, CD
    VAZEOS, E
    ENERGY CONVERSION AND MANAGEMENT, 1987, 27 (02) : 189 - 195
  • [5] Deck level air extraction and its impact on trichloramine concentrations in an indoor swimming pool: A numerical study
    Proulx, H.
    Debia, M.
    Halle, S.
    JOURNAL OF BUILDING ENGINEERING, 2023, 74
  • [6] On the model complexity of the air handling unit to investigate the energy efficiency of indoor swimming pool facilities
    Smedegard, Ole Oiene
    Aas, Bjorn
    Stene, Jorn
    Georges, Laurent
    ENERGY AND BUILDINGS, 2023, 293
  • [7] NUMERICAL MODEL AND EXPERIMENTAL VALIDATION OF THE HEAT TRANSFER IN AIR COOLED SOLAR PHOTOVOLTAIC PANEL
    Ranganathan, Senthil Kumar
    Elumalai, Natarajan
    Natarajan, Puja Priyadharshini
    THERMAL SCIENCE, 2016, 20 : S1071 - S1081
  • [8] Seasonal dynamics of water and air chemistry in an indoor chlorinated swimming pool
    Afifi, Mehrnaz Zare
    Blatchley, Ernest R., III
    WATER RESEARCH, 2015, 68 : 771 - 783
  • [9] Investigation of Air Quality Problems in an Indoor Swimming Pool: A Case Study
    Levesque, Benoit
    Vezina, Lorraine
    Gauvin, Denis
    Leroux, Patrice
    ANNALS OF OCCUPATIONAL HYGIENE, 2015, 59 (08): : 1085 - 1089
  • [10] Occupational asthma caused by chloramines in indoor swimming-pool air
    Thickett, KM
    McCoach, JS
    Gerber, JM
    Sadhra, S
    Burge, PS
    EUROPEAN RESPIRATORY JOURNAL, 2002, 19 (05) : 827 - 832