Chlorine concentrations in the air of indoor swimming pools and their effects on swimming pool workers

被引:10
|
作者
Fernandez-Luna, Alvaro [1 ]
Burillo, Pablo [2 ]
Luis Felipe, Jose [1 ]
Gallardo, Leonor [3 ]
Manuel Tamaral, Francisco [3 ]
机构
[1] Univ Europea Madrid, Fac Ciencias Actividad Fis & Deporte, Madrid, Spain
[2] Univ Camilo Jose Cela, Inst Ciencias Deporte, Madrid, Spain
[3] Univ Castilla La Mancha, Fac Ciencias Deporte, Toledo, Spain
关键词
Chlorine gas; Occupational health; Swimming pool; Ventilation; DISINFECTION BY-PRODUCTS; EXPOSURE; WATER; EPITHELIUM; SYMPTOMS; SWIMMERS; RISK;
D O I
10.1016/j.gaceta.2013.02.002
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: To describe chlorine levels in the air of indoor swimming pools in Castilla-La Mancha (Spain) and relate them to other chemical parameters in the installation and to the health problems perceived by swimming pool workers. Methods: We analyzed 21 pools with chlorine as chemical treatment in Castilla-La Mancha. The iodometry method was applied to measure chlorine concentrations in the air. The concentrations of free and combined chlorine in water, pH and temperature were also evaluated. Health problems were surveyed in 230 swimming pool workers in these facilities. Results: The mean chlorine level in the air of swimming pools was 4.3 +/- 2.3 mg/m(3). The pH values were within the legal limits. The temperature parameters did not comply with regulations in 17 of the 21 pools analyzed. In the pools where chlorine values in the air were above the legal regulations, a significantly higher percentage of swimming pool workers perceived eye irritation, dryness and irritation of skin, and ear problems. Conclusions: Chlorine values in the air of indoor swimming pools were higher than those reported in similar studies. Most of the facilities (85%) exceeded the concentration of 1.5 mg/m(3) established as the limit for the risk of irritating effects. The concentration of chlorine in indoor swimming pool air has a direct effect on the self-perceived health problems of swimming pool workers. (C) 2012 SESPAS. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:411 / 417
页数:7
相关论文
共 50 条
  • [1] Effects of indoor swimming pools on the nasal cytology of pool workers
    Erkul, E.
    Yaz, A.
    Cingi, C.
    Inancli, H. M.
    San, T.
    Bal, C.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2014, 128 (05): : 442 - 446
  • [2] Chlorine Gas Levels in Indoor Swimming Pools
    Taimura, Akihiro
    Matsunami, Masaru
    Sugawara, Masashi
    Arakawa, Takaaki
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 677 - 677
  • [3] Chlorine Gas Levels in Indoor Swimming Pools
    Taimura, Akihiro
    Matsunami, Masaru
    Sugawara, Masashi
    Arakawa, Takaaki
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 677 - 677
  • [4] Distribution and determinants of trihalomethane concentrations in indoor swimming pools
    Chu, H
    Nieuwenhuijsen, MJ
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2002, 59 (04) : 243 - 247
  • [5] Chlorine bad for swimming pools
    不详
    [J]. CHEMICAL ENGINEER-LONDON, 1996, (615-16): : 10 - 10
  • [7] Indoor air contamination in swimming pools of Gipuzkoa (Spain)
    Marina, L. Santa
    Ibarluzea, J.
    Basterretxea, M.
    Goni, F.
    Ulibarrena, E.
    Artieda, J.
    Orruno, I.
    [J]. EPIDEMIOLOGY, 2006, 17 (06) : S361 - S361
  • [8] Trihalomethanes in exhaled air, indoor air and water: A parallel design trial in chlorine and ozone-chlorine disinfected swimming pools
    Momeniha, Fatemeh
    Oskouie, Afsaneh Arefi
    Esrafili, Ali
    Janani, Leila
    Jafari, Ahmad Jonidi
    [J]. BUILDING AND ENVIRONMENT, 2021, 205
  • [9] PLASMA CHLOROFORM CONCENTRATIONS IN SWIMMERS USING INDOOR SWIMMING POOLS
    AGGAZZOTTI, G
    FANTUZZI, G
    TARTONI, PL
    PREDIERI, G
    [J]. ARCHIVES OF ENVIRONMENTAL HEALTH, 1990, 45 (03): : 175 - 179
  • [10] Environmental quality improvement on indoor swimming pools by application of chlorine dioxide
    Ling, Ing-may
    Lu, Ming-Chun
    Hsu, Ching-Shan
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2008, 17 (8A): : 1014 - 1021