Electrophysiology-based stratification of pancreatic tumorigenicity by label-free single-cell impedance cytometry

被引:48
|
作者
McGrath, J. S. [1 ]
Honrado, C. [1 ]
Moore, J. H. [1 ]
Adair, S. J. [2 ]
Varhue, W. B. [1 ]
Salahi, A. [1 ]
Farmehini, V. [1 ]
Goudreau, B. J. [2 ]
Nagdas, S. [2 ]
Blais, E. M. [2 ]
Bauer, T. W. [2 ]
Swami, N. S. [1 ]
机构
[1] Univ Virginia, Sch Engn & Appl Sci, Charlottesville, VA 22904 USA
[2] Univ Virginia, Sch Med, Dept Surg, Charlottesville, VA 22908 USA
关键词
Microfluidics; Impedance cytometry; Dielectrophoresis; Cancer; Pancreatic ductal adenocarcinoma; METABOTROPIC GLUTAMATE RECEPTORS; CIRCULATING TUMOR-CELLS; DUCTAL ADENOCARCINOMA; CANCER INCIDENCE; FLOW CYTOMETER; GENE ONTOLOGY; HETEROGENEITY; SPECTROSCOPY; CHEMOTHERAPY; DATABASE;
D O I
10.1016/j.aca.2019.12.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pancreatic ductal adenocarcinoma (PDAC) is an aggressive cancer lacking specific biomarkers that can be correlated to disease onset, promotion and progression. To assess whether tumor cell electrophysiology may serve as a marker for PDAC tumorigenicity, we use multi-frequency impedance cytometry at high throughput (similar to 350 cells/s) to measure the electrical phenotype of single PDAC tumor cells from xenografts, which are derived from primary pancreatic tumors versus those from liver metastases of different patients. A novel phase contrast metric based on variations in the high and low frequency impedance phase responses that is related to electrophysiology of the cell interior is found to be systematically altered as a function of tumorigenicity. PDAC cells of higher tumorigenicity exhibited lowered interior conductivity and enhanced permittivity, which is validated by the dielectrophoresis on the respective cell types. Using genetic analysis, we suggest the role of dysregulated Na+ transport and removal of Ca2+ ions from the cytoplasm on key oncogenic KRAS-driven processes that may be responsible for lowering of the interior cell conductivity. We envision that impedance cytometry can serve as a tool to quantify phenotypic heterogeneity for rapidly stratifying tumorigenicity. It can also aid in protocols for dielectrophoretic isolation of cells with a particular phenotype for prognostic studies on patient survival and to tailor therapy selection to specific patients. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 50 条
  • [31] Thermal inkjet makes label-free single-cell proteomics accessible and easy
    Stanisheuski, Stanislau
    Ebrahimi, Arpa
    Vaidya, Kavi Aashish
    Jang, Hyo Sang
    Yang, Liping
    Eddins, Alex Jordan
    Marean-Reardon, Carrie
    Franco, Maria Clara
    Maier, Claudia Susanne
    FRONTIERS IN CHEMISTRY, 2024, 12
  • [32] Label-free and ultrasensitive detection of polynucleotide kinase activity at the single-cell level
    Liu, Meng
    Ma, Fei
    Zhang, Qianyi
    Zhang, Chun-yang
    CHEMICAL COMMUNICATIONS, 2018, 54 (13) : 1583 - 1586
  • [33] Label-Free Discrimination of Rhizobial Bacteroids and Mutants by Single-Cell Raman Microspectroscopy
    Xu, Jiabao
    Webb, Isabel
    Poole, Philip
    Huang, Wei E.
    ANALYTICAL CHEMISTRY, 2017, 89 (12) : 6336 - 6340
  • [34] Single-cell Fourier-transform light scattering analysis by high-throughput label-free imaging flow cytometry
    Zhang, Ziqi
    Lai, Queenie T. K.
    Lee, Kelvin C. M.
    Wong, Kenneth K. Y.
    Tsia, Kevin K.
    2020 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2020,
  • [35] Single-cell classification based on label-free high-resolution optical data of cell adhesion kinetics
    Kovacs, Kinga Dora
    Beres, Balint
    Kanyo, Nicolett
    Szabo, Balint
    Peter, Beatrix
    Bosze, Szilvia
    Szekacs, Inna
    Horvath, Robert
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [36] Label-Free Microfluidic Impedance Cytometry for Acrosome Integrity Assessment of Boar Spermatozoa
    Kruit, Stella A.
    de Bruijn, Douwe S.
    Broekhuijse, Marleen L. W. J.
    Olthuis, Wouter
    Segerink, Loes, I
    BIOSENSORS-BASEL, 2022, 12 (09):
  • [37] Label-free quantitative lymphocyte activation profiling using microfluidic impedance cytometry
    Petchakup, Chayakorn
    Hutchinson, Paul Edward
    Tay, Hui Min
    Leong, Sheng Yuan
    Li, King Ho Holden
    Hou, Han Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 339
  • [38] Label-free single-cell analysis in microdroplets using a light-scattering-based optofluidic chip
    Liang, Li
    Liang, Minhui
    Zuo, Zewen
    Ai, Ye
    BIOSENSORS & BIOELECTRONICS, 2024, 253
  • [39] Label-free ghost cytometry for manufacturing of cell therapy products
    Teranishi, Kazuki
    Wagatsuma, Keisuke
    Toda, Keisuke
    Nomaru, Hiroko
    Yanagihashi, Yuichi
    Ochiai, Hiroshi
    Akai, Satoru
    Mochizuki, Emi
    Onda, Yuuki
    Nakagawa, Keiji
    Sugimoto, Keiki
    Takahashi, Shinya
    Yamaguchi, Hideto
    Ota, Sadao
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [40] Sorting by interfacial tension (SIFT): label-free selection of live cells based on single-cell metabolism
    Pan, Ching W.
    Horvath, Daniel G.
    Braza, Samuel
    Moore, Trevor
    Lynch, Annabella
    Feit, Cameron
    Abbyad, Paul
    LAB ON A CHIP, 2019, 19 (08) : 1344 - 1351