Electrophysiology-based stratification of pancreatic tumorigenicity by label-free single-cell impedance cytometry

被引:48
|
作者
McGrath, J. S. [1 ]
Honrado, C. [1 ]
Moore, J. H. [1 ]
Adair, S. J. [2 ]
Varhue, W. B. [1 ]
Salahi, A. [1 ]
Farmehini, V. [1 ]
Goudreau, B. J. [2 ]
Nagdas, S. [2 ]
Blais, E. M. [2 ]
Bauer, T. W. [2 ]
Swami, N. S. [1 ]
机构
[1] Univ Virginia, Sch Engn & Appl Sci, Charlottesville, VA 22904 USA
[2] Univ Virginia, Sch Med, Dept Surg, Charlottesville, VA 22908 USA
关键词
Microfluidics; Impedance cytometry; Dielectrophoresis; Cancer; Pancreatic ductal adenocarcinoma; METABOTROPIC GLUTAMATE RECEPTORS; CIRCULATING TUMOR-CELLS; DUCTAL ADENOCARCINOMA; CANCER INCIDENCE; FLOW CYTOMETER; GENE ONTOLOGY; HETEROGENEITY; SPECTROSCOPY; CHEMOTHERAPY; DATABASE;
D O I
10.1016/j.aca.2019.12.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pancreatic ductal adenocarcinoma (PDAC) is an aggressive cancer lacking specific biomarkers that can be correlated to disease onset, promotion and progression. To assess whether tumor cell electrophysiology may serve as a marker for PDAC tumorigenicity, we use multi-frequency impedance cytometry at high throughput (similar to 350 cells/s) to measure the electrical phenotype of single PDAC tumor cells from xenografts, which are derived from primary pancreatic tumors versus those from liver metastases of different patients. A novel phase contrast metric based on variations in the high and low frequency impedance phase responses that is related to electrophysiology of the cell interior is found to be systematically altered as a function of tumorigenicity. PDAC cells of higher tumorigenicity exhibited lowered interior conductivity and enhanced permittivity, which is validated by the dielectrophoresis on the respective cell types. Using genetic analysis, we suggest the role of dysregulated Na+ transport and removal of Ca2+ ions from the cytoplasm on key oncogenic KRAS-driven processes that may be responsible for lowering of the interior cell conductivity. We envision that impedance cytometry can serve as a tool to quantify phenotypic heterogeneity for rapidly stratifying tumorigenicity. It can also aid in protocols for dielectrophoretic isolation of cells with a particular phenotype for prognostic studies on patient survival and to tailor therapy selection to specific patients. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 50 条
  • [21] Label-free biosensing of Salmonella enterica serovars at single-cell level
    Bin Wang
    Bosoon Park
    Bingqian Xu
    Yongkuk Kwon
    Journal of Nanobiotechnology, 15
  • [22] High accuracy label-free classification of single-cell kinetic states from holographic cytometry of human melanoma cells
    Miroslav Hejna
    Aparna Jorapur
    Jun S. Song
    Robert L. Judson
    Scientific Reports, 7
  • [23] Hazelnut Pollen Phenotyping Using Label-Free Impedance Flow Cytometry
    Ascari, Lorenzo
    Cristofori, Valerio
    Macri, Federico
    Botta, Roberto
    Silvestri, Cristian
    De Gregorio, Tommaso
    Huerta, Eloy Suarez
    Di Berardino, Marco
    Kaufmann, Silvan
    Siniscalco, Consolata
    FRONTIERS IN PLANT SCIENCE, 2020, 11
  • [24] OSMOTIC ERYTHROCYTE LYSIS FOR CHEMICAL- AND LABEL-FREE IMPEDANCE CYTOMETRY
    Winkler, T. E.
    Ben-Yoav, H.
    Kelly, D. L.
    Ghodssi, R.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 351 - 354
  • [25] Direct and Label-Free Cell Status Monitoring of Spheroids and Microcarriers Using Microfluidic Impedance Cytometry
    Gong, Lingyan
    Petchakup, Chayakorn
    Shi, Pujiang
    Tan, Pei Leng
    Tan, Lay Poh
    Tay, Chor Yong
    Hou, Han Wei
    SMALL, 2021, 17 (21)
  • [26] Label-Free Sensing of Cell Viability Using a Low-Cost Impedance Cytometry Device
    Yang, Bowen
    Wang, Chao
    Liang, Xinyi
    Li, Jinchao
    Li, Shanshan
    Wu, Jie Jayne
    Su, Tanbin
    Li, Junwei
    MICROMACHINES, 2023, 14 (02)
  • [27] High accuracy label-free classification of single-cell kinetic states from holographic cytometry of human melanoma cells
    Hejna, Miroslav
    Jorapur, Aparna
    Song, Jun S.
    Judson, Robert L.
    SCIENTIFIC REPORTS, 2017, 7
  • [28] Microscope-based label-free microfluidic cytometry
    Su, Xuantao
    Kirkwood, Sean E.
    Gupta, Manisha
    Marquez-Curtis, Leah
    Qiu, Yuanyuan
    Janowska-Wieczorek, Anna
    Rozmus, Wojciech
    Tsui, Ying Y.
    OPTICS EXPRESS, 2011, 19 (01): : 387 - 398
  • [29] Recent Advances in Plasmonic Nanostructures Applied for Label-free Single-cell Analysis
    Liao, Xue-Wei
    Xu, Qiu-Yang
    Tan, Zheng
    Liu, Yang
    Wang, Chen
    ELECTROANALYSIS, 2022, 34 (06) : 923 - 936
  • [30] Label-free and noninvasive analysis of microorganism surface epistructures at the single-cell level
    Lin, Yu-Sheng
    Sun, Chen-li
    Tsang, Sung
    Bensalem, Sakina
    Le Pioufle, Bruno
    Wang, Hsiang -Yu
    BIOPHYSICAL JOURNAL, 2023, 122 (10) : 1794 - 1806