Electrophysiology-based stratification of pancreatic tumorigenicity by label-free single-cell impedance cytometry

被引:48
|
作者
McGrath, J. S. [1 ]
Honrado, C. [1 ]
Moore, J. H. [1 ]
Adair, S. J. [2 ]
Varhue, W. B. [1 ]
Salahi, A. [1 ]
Farmehini, V. [1 ]
Goudreau, B. J. [2 ]
Nagdas, S. [2 ]
Blais, E. M. [2 ]
Bauer, T. W. [2 ]
Swami, N. S. [1 ]
机构
[1] Univ Virginia, Sch Engn & Appl Sci, Charlottesville, VA 22904 USA
[2] Univ Virginia, Sch Med, Dept Surg, Charlottesville, VA 22908 USA
关键词
Microfluidics; Impedance cytometry; Dielectrophoresis; Cancer; Pancreatic ductal adenocarcinoma; METABOTROPIC GLUTAMATE RECEPTORS; CIRCULATING TUMOR-CELLS; DUCTAL ADENOCARCINOMA; CANCER INCIDENCE; FLOW CYTOMETER; GENE ONTOLOGY; HETEROGENEITY; SPECTROSCOPY; CHEMOTHERAPY; DATABASE;
D O I
10.1016/j.aca.2019.12.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pancreatic ductal adenocarcinoma (PDAC) is an aggressive cancer lacking specific biomarkers that can be correlated to disease onset, promotion and progression. To assess whether tumor cell electrophysiology may serve as a marker for PDAC tumorigenicity, we use multi-frequency impedance cytometry at high throughput (similar to 350 cells/s) to measure the electrical phenotype of single PDAC tumor cells from xenografts, which are derived from primary pancreatic tumors versus those from liver metastases of different patients. A novel phase contrast metric based on variations in the high and low frequency impedance phase responses that is related to electrophysiology of the cell interior is found to be systematically altered as a function of tumorigenicity. PDAC cells of higher tumorigenicity exhibited lowered interior conductivity and enhanced permittivity, which is validated by the dielectrophoresis on the respective cell types. Using genetic analysis, we suggest the role of dysregulated Na+ transport and removal of Ca2+ ions from the cytoplasm on key oncogenic KRAS-driven processes that may be responsible for lowering of the interior cell conductivity. We envision that impedance cytometry can serve as a tool to quantify phenotypic heterogeneity for rapidly stratifying tumorigenicity. It can also aid in protocols for dielectrophoretic isolation of cells with a particular phenotype for prognostic studies on patient survival and to tailor therapy selection to specific patients. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 50 条
  • [1] Single-cell laser emitting cytometry for label-free nucleolus fingerprinting
    Fang, Guocheng
    Qiao, Zhen
    Huang, Luqi
    Zhu, Hui
    Xie, Jun
    Zhou, Tian
    Xiong, Zhongshu
    Su, I-Hsin
    Jin, Dayong
    Chen, Yu-Cheng
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [2] Single-cell cytometry via multiplexed fluorescence prediction by label-free reflectance microscopy
    Cheng, Shiyi
    Fu, Sipei
    Kim, Yumi Mun
    Song, Weiye
    Li, Yunzhe
    Xue, Yujia
    Yi, Ji
    Tian, Lei
    SCIENCE ADVANCES, 2021, 7 (03):
  • [3] Label-free microfluidics for single-cell analysis
    Chen, Yao
    Zhou, Zheng
    Zhu, Shu
    Ni, Zhonghua
    Xiang, Nan
    MICROCHEMICAL JOURNAL, 2022, 177
  • [4] Impedance spectroscopy flow cytometry: Parameters for label-free cell differentiation
    Cheung, K
    Gawad, S
    Renaud, P
    Micro Total Analysis Systems 2004, Vol 1, 2005, (296): : 55 - 57
  • [5] Label-free differential leukocyte counts using a microfabricated, single-cell impedance spectrometer
    Holmes, David
    Sun, Tao
    Morgan, Hywel
    Holloway, Judith
    Cakebread, Julie
    Davies, Donna
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 1452 - 1455
  • [6] Single-cell label-free photoacoustic flowoxigraphy in vivo
    Wang, Lidai
    Maslov, Konstantin
    Wang, Lihong V.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (15) : 5759 - 5764
  • [7] Microfluidic Impedance-Deformability Cytometry for Label-Free Single Neutrophil Mechanophenotyping
    Petchakup, Chayakorn
    Yang, Haoning
    Gong, Lingyan
    He, Linwei
    Tay, Hui Min
    Dalan, Rinkoo
    Chung, Aram J.
    Li, King Ho Holden
    Hou, Han Wei
    SMALL, 2022, 18 (18)
  • [8] Label-free impedance flow cytometry for nanotoxicity screening
    Ostermann, Melanie
    Sauter, Alexander
    Xue, Ying
    Birkeland, Eivind
    Schoelermann, Julia
    Holst, Bodil
    Cimpan, Mihaela Roxana
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] Label-free impedance flow cytometry for nanotoxicity screening
    Melanie Ostermann
    Alexander Sauter
    Ying Xue
    Eivind Birkeland
    Julia Schoelermann
    Bodil Holst
    Mihaela Roxana Cimpan
    Scientific Reports, 10
  • [10] Impedance spectroscopy flow cytometry: On-chip label-free cell differentiation
    Cheung, K
    Gawad, S
    Renaud, P
    CYTOMETRY PART A, 2005, 65A (02) : 124 - 132