Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement

被引:42
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [2 ]
Yeh, Victoria [2 ]
Chiou, Allen J. [2 ]
Gorrepati, Madhu L.
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Dept Surg, Clark Ctr E350A, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
ENDOVASCULAR ANEURYSM REPAIR; STENT-GRAFT MIGRATION; BLOOD-FLOW; TRIAL;
D O I
10.1016/j.jvs.2010.01.058
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective:Endograft migration is usually described as a downward displacement of the endograft with respect to the renal arteries. However, change in endograft position is actually a complex process in three-dimensional (3D) space. Currently, there are no established techniques to define such positional changes over time. The purpose of this study is to determine whether the direction of aortic endograft movement as observed in follow-up computed tomography (CT) scans is related to the directional displacement force acting on the endograft. Methods: We quantitated the 3D positional change over time of five abdominal endografts by determining the endograft centroid at baseline (postoperative scan) and on follow-up CT scans. The time interval between CT scans for the 5 patients ranged from 8 months to 8 years. We then used 3D image segmentation and computational fluid dynamics (CFD) techniques to quantitate the pulsatile displacement force (in Newtons [NI]) acting on the endografts in the postoperative configurations. Finally, we calculated a correlation metric between the direction of the displacement force vector and the endograft movement by computing the cosine of the angle of these two vectors. Results: The average 3D movement of the endograft centroid was 18 mm (range, 9-29 mm) with greater movement in patients with longer follow-up times. In all cases, the movement of the endograft had significant components in all three spatial directions: Two of the endografts had the largest component of movement in the transverse direction, whereas three endografts had the largest component of movement in the axial direction. The magnitude and orientation of the endograft displacement force varied depending on aortic angulation and hemodynamic conditions. The average magnitude of displacement force for all endografts was 5.8 N (range, 3.7-9.5 N). The orientation of displacement force was in general perpendicular to the greatest curvature of the endograft. The average correlation metric, defined as the cosine of the angle between the displacement force and the endograft centroid movement, was 0.38 (range, 0.08-0.66). Conclusions: Computational methods applied to patient-specific postoperative image data can be used to quantitate 3D displacement force and movement of endografts over time. It appears that endograft movement is related to the magnitude and direction of the displacement force acting on aortic endografts. These methods can be used to increase our understanding of clinical endograft migration. (J Vase Surg 2010;51:1488-97.)
引用
收藏
页码:1488 / 1497
页数:10
相关论文
共 50 条
  • [21] Force sensing using 3D displacement measurements in linear elastic bodies
    Xinzeng Feng
    Chung-Yuen Hui
    Computational Mechanics, 2016, 58 : 91 - 105
  • [22] Aortic morphometry at endograft position as assessed by 3D image analysis affects risk of type I endoleak formation after TEVAR
    Drosos Kotelis
    Carolin Brenke
    Stefan Wörz
    Fabian Rengier
    Karl Rohr
    Hans-Ulrich Kauczor
    Dittmar Böckler
    Hendrik von Tengg-Kobligk
    Langenbeck's Archives of Surgery, 2015, 400 : 523 - 529
  • [23] The distribution and relationship between 3D LVEF and 3D strain in a general population
    Ericsson, F.
    Tayal, B.
    Zaremba, T.
    Schnohr, P.
    Jensen, G.
    Mogelvang, R.
    Soegaard, P.
    EUROPEAN HEART JOURNAL, 2020, 41 : 25 - 25
  • [24] Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3 T without contrast enhancement
    Merton, Renske
    Bosshardt, Daan
    Strijkers, Gustav J.
    Nederveen, Aart J.
    Schrauben, Eric M.
    van Ooij, Pim
    MAGNETIC RESONANCE IN MEDICINE, 2023, 91 (02) : 466 - 480
  • [25] SIMULATION OF DYNAMIC BEHAVIOUR OF A DIGITAL DISPLACEMENT MOTOR USING TRANSIENT 3D COMPUTATIONAL FLUID DYNAMICS ANALYSIS
    Roemer, Daniel B.
    Johansen, Per
    Pedersen, Henrik C.
    Andersen, Torben O.
    PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2013, 2014,
  • [26] The kinelite system for 3D movement analysis in microgravity
    McIntyre, J
    Venet, M
    Zaoui, M
    2ND EUROPEAN SYMPOSIUM ON UTILISATION OF THE INTERNATIONAL SPACE STATION, 1999, 433 : 477 - 482
  • [27] Investigation of the relationship between age and the angle of aortic insertion on the left ventricle using 3D MRI
    Raphael D Hazel
    Simcha Pollack
    Nathaniel Reichek
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [28] 3D volumetric displacement and strain analysis of composite polymerization
    Van Ende, Annelies
    Van de Casteele, Elke
    Depypere, Maarten
    De Munck, Jan
    Li, Xin
    Maes, Frederik
    Wevers, Martine
    Van Meerbeek, Bart
    DENTAL MATERIALS, 2015, 31 (04) : 453 - 461
  • [29] Automated 3D Analysis of Zygomaticomaxillary Fracture Rotation and Displacement
    Prabhu, Shamit S.
    Chung, Scotty A.
    Rudolph, Megan A.
    Hemal, Kshipra
    Brown, Philip J.
    Runyan, Christopher M.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2021, 9 (10) : E3888
  • [30] Basic Computational Algorithms for Representing an Aircraft Flight (Calculation of 3D Displacement and Displaying)
    Ramirez-Lopez, Adan
    AXIOMS, 2024, 13 (05)