Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3 T without contrast enhancement

被引:2
|
作者
Merton, Renske [1 ,2 ]
Bosshardt, Daan [1 ,2 ]
Strijkers, Gustav J. [2 ,3 ]
Nederveen, Aart J. [1 ,2 ,4 ]
Schrauben, Eric M. [1 ,2 ]
van Ooij, Pim [1 ,2 ,4 ]
机构
[1] Locat Univ Amsterdam, Amsterdam UMC, Radiol & Nucl Med, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Locat Univ Amsterdam, Amsterdam UMC, Biomed Phys & Engn, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Amsterdam, Netherlands
基金
荷兰研究理事会;
关键词
3; T; 3D cine bSSFP; aorta; aortic motion; displacement; nonrigid registration; ROOT MOTION; MRI; REGISTRATION; RELIABILITY; VELOCITY; STRESS; ECG;
D O I
10.1002/mrm.29856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose :Aortic motion has direct impact on the mechanical stresses acting on the aorta. In aortic disease, increased stiffness of the aorta may lead to decreased aortic motion over time, which could be a predictor for aortic dissection or rupture. This study investigates the reproducibility of obtaining 3D displacement and diameter maps quantified using accelerated 3D cine MRI at 3 T.Methods :A noncontrast-enhanced, free-breathing 3D cine sequence based on balanced SSFP and pseudo-spiral undersampling with high spatial isotropic resolution was developed (spatial/temporal resolution [1.6 mm]3/67 ms). The thoracic aorta of 14 healthy volunteers was prospectively scanned three times at 3 T: twice on the same day and a third time 2 weeks later. Aortic displacement was calculated using iterative closest point nonrigid registration of manual segmentations of the 3D aorta at end-systole and mid-diastole. Interexamination and interobserver regional analysis of mean displacement for five regions of interest was performed using Bland-Altman analysis. Additionally, a complementary voxel-by-voxel analysis was done, allowing a more local inspection of the method.Results :No significant differences were found in mean and maximum displacement for any of the regions of interest for the interexamination and interobserver analysis. The maximum displacement measured in the lower half of the ascending aorta was 11.0 +/- 3.4 mm (range: 3.0-17.5 mm) for the first scan. The smallest detectable change in mean displacement in the lower half of the ascending aorta was 3 mm.Conclusion :Detailed 3D cine balanced SSFP at 3 T allows for reproducible quantification of systolic-diastolic mean aortic displacement within acceptable limits.
引用
收藏
页码:466 / 480
页数:15
相关论文
共 50 条
  • [1] Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3T without contrast enhancement
    Merton, Renske
    Bosshardt, Daan
    Strijkers, Gustav J.
    Nederveen, Aart J.
    Schrauben, Eric M.
    van Ooij, Pim
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 466 - 480
  • [2] Single breathhold 3D balanced SSFP coronary MRA at 3.0T: a reproducibility study
    Sahar Soleimanifard
    Matthias Stuber
    Allison Hays
    Robert G Weiss
    Michael Schär
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [3] 1119 Direct comparison of the signal-to-noise ratio for 3D and 2D balanced SSFP cine imaging
    Dana C Peters
    Daniel A Herzka
    Reza Nezafat
    Warren J Manning
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [4] Artifact suppression of SSFP cine sequences at 3T using a novel automatic 3D shimming algorithm
    Tamara Rothstein
    Gabriel C Camargo
    Daniel C Quintella
    Elsa Fernandes
    Ralph Strecker
    Andreas Greiser
    Maria Eduarda Derenne
    Marceu Lima
    Joao J Moojen
    Patricia B Rizzi
    Ronaldo SL Lima
    Ilan Gottlieb
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [5] 3D Velocity Quantification in the Heart: Improvements by 3D PC-SSFP
    Rolf, Marijn P.
    Hofman, Mark B. M.
    Kuijer, Joost P. A.
    van Rossum, Albert C.
    Heethaar, Rob M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 947 - 955
  • [6] Routine 3D SSFP cine imaging for improved analysis of myocardial volumetry and deformation
    Bram Ruijsink
    María N Velasco Forte
    Miguel S Vieira
    Rene M Botnar
    Tarique Hussain
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [7] 3D geometric reconstruction of thoracic aortic aneurysms
    Borghi, Alessandro
    Wood, Nigel B.
    Mohiaddin, Raad H.
    Xu, X. Yun
    BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [8] 3D geometric reconstruction of thoracic aortic aneurysms
    Alessandro Borghi
    Nigel B Wood
    Raad H Mohiaddin
    X Yun Xu
    BioMedical Engineering OnLine, 5
  • [9] SimpleRecon: 3D Reconstruction Without 3D Convolutions
    Sayed, Mohamed
    Gibson, John
    Watson, Jamie
    Prisacariu, Victor
    Firman, Michael
    Godard, Clement
    COMPUTER VISION - ECCV 2022, PT XXXIII, 2022, 13693 : 1 - 19
  • [10] Aortic Valve and Ascending Aortic Root Modeling from 3D and 3D+t CT
    Grbic, Sasa
    Ionasec, Razvan Ioan
    Zaeuner, Dominik
    Zheng, Yefeng
    Georgescu, Bogdan
    Comaniciu, Dorin
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625