Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3 T without contrast enhancement

被引:2
|
作者
Merton, Renske [1 ,2 ]
Bosshardt, Daan [1 ,2 ]
Strijkers, Gustav J. [2 ,3 ]
Nederveen, Aart J. [1 ,2 ,4 ]
Schrauben, Eric M. [1 ,2 ]
van Ooij, Pim [1 ,2 ,4 ]
机构
[1] Locat Univ Amsterdam, Amsterdam UMC, Radiol & Nucl Med, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Locat Univ Amsterdam, Amsterdam UMC, Biomed Phys & Engn, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Amsterdam, Netherlands
基金
荷兰研究理事会;
关键词
3; T; 3D cine bSSFP; aorta; aortic motion; displacement; nonrigid registration; ROOT MOTION; MRI; REGISTRATION; RELIABILITY; VELOCITY; STRESS; ECG;
D O I
10.1002/mrm.29856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose :Aortic motion has direct impact on the mechanical stresses acting on the aorta. In aortic disease, increased stiffness of the aorta may lead to decreased aortic motion over time, which could be a predictor for aortic dissection or rupture. This study investigates the reproducibility of obtaining 3D displacement and diameter maps quantified using accelerated 3D cine MRI at 3 T.Methods :A noncontrast-enhanced, free-breathing 3D cine sequence based on balanced SSFP and pseudo-spiral undersampling with high spatial isotropic resolution was developed (spatial/temporal resolution [1.6 mm]3/67 ms). The thoracic aorta of 14 healthy volunteers was prospectively scanned three times at 3 T: twice on the same day and a third time 2 weeks later. Aortic displacement was calculated using iterative closest point nonrigid registration of manual segmentations of the 3D aorta at end-systole and mid-diastole. Interexamination and interobserver regional analysis of mean displacement for five regions of interest was performed using Bland-Altman analysis. Additionally, a complementary voxel-by-voxel analysis was done, allowing a more local inspection of the method.Results :No significant differences were found in mean and maximum displacement for any of the regions of interest for the interexamination and interobserver analysis. The maximum displacement measured in the lower half of the ascending aorta was 11.0 +/- 3.4 mm (range: 3.0-17.5 mm) for the first scan. The smallest detectable change in mean displacement in the lower half of the ascending aorta was 3 mm.Conclusion :Detailed 3D cine balanced SSFP at 3 T allows for reproducible quantification of systolic-diastolic mean aortic displacement within acceptable limits.
引用
收藏
页码:466 / 480
页数:15
相关论文
共 50 条
  • [41] 3D epigenomics and 3D epigenopathies
    Lee, Kyung-Hwan
    Kim, Jungyu
    Kim, Ji Hun
    BMB REPORTS, 2024, 57 (05) : 216 - 231
  • [43] VIEWING 3D IMAGES IN 3D
    MAHONEY, DP
    COMPUTER GRAPHICS WORLD, 1995, 18 (03) : 19 - 20
  • [45] A 3D moviemap and a 3D panorama
    Naimark, M
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS IV, 1997, 3012 : 297 - 305
  • [46] Native high-resolution 3D SSFP MR angiography for assessing the thoracic aorta
    Florian von Knobelsdorff
    Henriette Gruettner
    Ralf F Trauzeddel
    Andreas Greiser
    Jeanette Schulz-Menger
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [47] 3D imaging, 3D printing and 3D virtual planning in endodontics
    Shah, Pratik
    Chong, B. S.
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (02) : 641 - 654
  • [48] Optimized 3D bright blood MRI of aortic plaque at 3 T
    Markl, Michael
    Dudler, Patrick
    Fydrychowicz, Alex
    Strecker, Christoph
    Weiller, Cornelius
    Hennig, Eirgen
    Harloff, Andreas
    MAGNETIC RESONANCE IMAGING, 2008, 26 (03) : 330 - 336
  • [49] 3D imaging, 3D printing and 3D virtual planning in endodontics
    Pratik Shah
    B. S. Chong
    Clinical Oral Investigations, 2018, 22 : 641 - 654
  • [50] Reproducibility of 3D scanning in the periorbital region
    Maria H. J. Hollander
    Joep Kraeima
    Anne M. L. Meesters
    Konstantina Delli
    Arjan Vissink
    Johan Jansma
    Rutger H. Schepers
    Scientific Reports, 11