Detector sensitivity influences blood flow sampling in scanning laser Doppler flowmetry

被引:19
|
作者
Hosking, SL
Embleton, S
Kagemann, L
Chabra, A
Jonescu-Cuypers, C
Harris, A
机构
[1] Aston Univ, Neurosci Res Inst, Birmingham B4 7ET, W Midlands, England
[2] Indiana Univ, Dept Ophthalmol, Glaucoma Res & Diagnost Ctr, Indianapolis, IN 46204 USA
关键词
D O I
10.1007/s004170100283
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish the effect of photodiode sensitivity on the DC (brightness) value and the resultant blood flow measurements of retina and rim tissue using a scanning laser Doppler flowmeter (SLDF). Methods: The sample consisted of one eye of each of 15 healthy subjects (mean age 27.8 +/- 6.1 years). Using the Heidelberg Retina Flowmeter (HRF), three 10-deg images of the superior temporal retina and three further images of the superior temporal rim were acquired for each of five DC bands: band 1: 30-70; band 2: 70-110; band 3: 110-150; band 4 150-190; band 5: 190-230. Retinal blood volume, flow and velocity were determined for each image using a 10 x 10 pixel square grid located at a predetermined location on the retina and rim for each subject. Following image acquisition, the DC values corresponding to each pre-assigned retinal or rim location were determined. The mean and standard deviation were determined for the blood flow parameters within each DC band for each subject in both locations. Analysis of variance was used to identify significant change in the data as a function of the DC value (P<0.05). Results: Analysis of variance revealed that retinal blood flow measures acquired within DC band 5 resulted in significantly lower measures of blood flow and velocity (P=0.035 and P=0.049 respectively) than at lower DC values. Band 5 values of flow, volume and velocity in the neuroretinal rim were also significantly low (P=0.016, P= 0.003 and P=0.026 respectively). Peak neuroretinal rim blood flow was recorded when the DC value was between 70 and 110. For blood flow measurement at the retina and neuroretinal rim the DC value should not exceed 190. Conclusion: Photodiode sensitivity as indicated by the DC value affects measurements of ocular blood flow using the HRF.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 50 条
  • [41] SCANNING LASER DOPPLER FLOWMETRY OF RETINAL BLOOD FLOW IN EARLY STAGE AUTOSOMAL DOMINANT POLYCYSTIC KIDNEY DISEASE
    Jankowska, Magdalena
    Miszkowska, Eliza
    Szyndler, Anna
    Stefanski, Adrian
    Krol, Ewa
    Biedunkiewicz, Bogdan
    Chrostowska, Marzena
    Harazny, Joanna
    Schmieder, Roland
    Debska-Slizien, Alicja
    Narkiewicz, Krzysztof
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33
  • [42] Ocular blood flow assessment using continuous laser Doppler flowmetry
    Riva, Charles E.
    Geiser, Martial
    Petrig, Benno L.
    ACTA OPHTHALMOLOGICA, 2010, 88 (06) : 622 - 629
  • [43] LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF GASTRIC BLOOD-FLOW IN MAN
    AHN, H
    JOHANSSON, K
    LINDHAGEN, J
    SALERUD, EG
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1984, 19 : 33 - 33
  • [44] Blood flow measurements of optic nerve head rim tissue as a function of illumination with scanning laser Doppler flowmetry
    Embleton, SJ
    Hosking, SL
    Pettinger, C
    Kagemann, L
    Chabra, A
    Chung, HS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S276 - S276
  • [45] Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations
    Roeykens, Herman J. J.
    Deschepper, Ellen
    De Moor, Roeland J. G.
    LASERS IN MEDICAL SCIENCE, 2016, 31 (06) : 1083 - 1092
  • [46] Laser Doppler flowmetry of pulpal blood flow during the dental leveling
    Salles, WRA
    Nogueira, GEC
    Lage-Marques, JL
    Vidal, JT
    Zezell, DM
    LASERS IN SURGERY AND MEDICINE, 2004, : 53 - 53
  • [47] EVALUATION OF COCHLEAR BLOOD-FLOW MEASUREMENT BY LASER DOPPLER FLOWMETRY
    TAMURA, T
    OKAMOTO, A
    KOBAYASHI, N
    YOKOYAMA, K
    HASEGAWA, M
    TOGAWA, T
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1185 - 1186
  • [48] LASER DIODE DOPPLER FLOWMETRY FOR EVALUATION MICROVASCULAR BLOOD-FLOW
    KOLARI, PJ
    FEDERATION PROCEEDINGS, 1985, 44 (05) : 1565 - 1565
  • [49] Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations
    Herman J. J. Roeykens
    Ellen Deschepper
    Roeland J. G. De Moor
    Lasers in Medical Science, 2016, 31 : 1083 - 1092
  • [50] Skin blood flow responses during sleep by laser Doppler flowmetry
    Shiihara, Y
    Hirota, A
    Kobayashi, Y
    Nakamiya, T
    Kodama, M
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1999, 53 (02) : 117 - 119