Detector sensitivity influences blood flow sampling in scanning laser Doppler flowmetry

被引:19
|
作者
Hosking, SL
Embleton, S
Kagemann, L
Chabra, A
Jonescu-Cuypers, C
Harris, A
机构
[1] Aston Univ, Neurosci Res Inst, Birmingham B4 7ET, W Midlands, England
[2] Indiana Univ, Dept Ophthalmol, Glaucoma Res & Diagnost Ctr, Indianapolis, IN 46204 USA
关键词
D O I
10.1007/s004170100283
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish the effect of photodiode sensitivity on the DC (brightness) value and the resultant blood flow measurements of retina and rim tissue using a scanning laser Doppler flowmeter (SLDF). Methods: The sample consisted of one eye of each of 15 healthy subjects (mean age 27.8 +/- 6.1 years). Using the Heidelberg Retina Flowmeter (HRF), three 10-deg images of the superior temporal retina and three further images of the superior temporal rim were acquired for each of five DC bands: band 1: 30-70; band 2: 70-110; band 3: 110-150; band 4 150-190; band 5: 190-230. Retinal blood volume, flow and velocity were determined for each image using a 10 x 10 pixel square grid located at a predetermined location on the retina and rim for each subject. Following image acquisition, the DC values corresponding to each pre-assigned retinal or rim location were determined. The mean and standard deviation were determined for the blood flow parameters within each DC band for each subject in both locations. Analysis of variance was used to identify significant change in the data as a function of the DC value (P<0.05). Results: Analysis of variance revealed that retinal blood flow measures acquired within DC band 5 resulted in significantly lower measures of blood flow and velocity (P=0.035 and P=0.049 respectively) than at lower DC values. Band 5 values of flow, volume and velocity in the neuroretinal rim were also significantly low (P=0.016, P= 0.003 and P=0.026 respectively). Peak neuroretinal rim blood flow was recorded when the DC value was between 70 and 110. For blood flow measurement at the retina and neuroretinal rim the DC value should not exceed 190. Conclusion: Photodiode sensitivity as indicated by the DC value affects measurements of ocular blood flow using the HRF.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 50 条
  • [31] ASSESSMENT OF CANCELLOUS BONE BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    NILSSON, GE
    HELLEM, S
    JACOBSSON, L
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (03): : 299 - 299
  • [32] The use of laser Doppler flowmetry to evaluate anterior cruciate blood flow
    Schlehr, F.J.
    Limbird, T.A.
    Swiontkowski, M.F.
    Keller, T.S.
    1600, (05):
  • [33] LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF INTESTINAL BLOOD-FLOW IN MAN
    LINDHAGEN, J
    AHN, H
    SALERUD, EG
    JODAL, M
    LUNDGREN, O
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (3-4): : 478 - 478
  • [34] MEASUREMENT OF SKIN BLOOD-FLOW USING LASER DOPPLER FLOWMETRY
    SVENSSON, H
    JONSSON, BA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 205 - 205
  • [35] GINGIVAL BLOOD-FLOW STUDIES USING LASER DOPPLER FLOWMETRY
    OBERG, PA
    BAAB, DA
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1647 - 1649
  • [36] Reliability of Skin Blood Flow Measures by Laser-Doppler Flowmetry
    Herron, Robert
    Carter, Stephen
    Collins, Ann
    Leatherwood, Matthew
    FASEB JOURNAL, 2015, 29
  • [37] Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
    Adair, HS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 422 - 425
  • [38] LASER-DOPPLER FLOWMETRY FOR ESTIMATING LIVER BLOOD-FLOW
    ARVIDSSON, D
    SVENSSON, H
    HAGLUND, U
    AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (04): : G471 - G476
  • [39] Measurement of blood flow in the rotator cuff using laser Doppler flowmetry
    Levy, O.
    Relwani, J.
    Zaman, T.
    Even, T.
    Venkateswaran, B.
    Copeland, S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07): : 893 - 898
  • [40] ASSESSMENT OF CANCELLOUS BONE BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    HELLEM, S
    JACOBSSON, L
    NILSSON, GE
    LEWIS, DH
    SWEDISH DENTAL JOURNAL, 1982, 6 (06) : 260 - 260