Undersampled Cine 3D tagging for rapid assessment of cardiac motion

被引:13
|
作者
Stoeck, Christian T. [1 ,2 ]
Manka, Robert [1 ,2 ,3 ]
Boesiger, Peter [1 ,2 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, CH-8092 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Cardiol, CH-8091 Zurich, Switzerland
[4] Kings Coll London, London, England
基金
瑞士国家科学基金会;
关键词
Motion analysis; Myocardial tagging; k-t undersampling; Principal component analysis; Image reconstruction; K-T BLAST; MAGNETIC-RESONANCE; MYOCARDIAL-PERFUSION; SPATIAL-RESOLUTION; RESPIRATORY MOTION; AORTIC-STENOSIS; DYNAMIC MRI; DENSE MRI; TRACKING; CONTRAST;
D O I
10.1186/1532-429X-14-60
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. Methods: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. Results: In computer simulations, the error for circumferential shortening was 2.8 +/- 2.3% and 2.7 +/- 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 +/- 1.9% and 3.0 +/- 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of -0.14 +/- 5.18% and 0.71 +/- 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 +/- 1.8 and 0.73 +/- 1.67 for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced ( p < 0.002 for all patients) in regions with late gadolinium enhancement. Conclusion: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] 3D visualization of myocardial motion and blood flow using cine-MR images
    Oshiro, O
    Matani, A
    Chihara, K
    Mikami, T
    Kitabatake, A
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 658 - 659
  • [32] Multi-frame fusion of undersampled 3D imagery
    Cain, Stephen C.
    [J]. UNCONVENTIONAL IMAGING AND WAVEFRONT SENSING 2012, 2012, 8520
  • [33] 3D cardiac navigation with rapid multi shot EPI
    Aaron T Hess
    André J van der Kouwe
    Stefan Neubauer
    Matthew D Robson
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [34] Motion corrected LV quantification based on 3D modelling for improved functional assessment in cardiac MRI
    Liew, Y. M.
    McLaughlin, R. A.
    Chan, B. T.
    Aziz, Y. F. Abdul
    Chee, K. H.
    Ung, N. M.
    Tan, L. K.
    Lai, K. W.
    Ng, S.
    Lim, E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : 2715 - 2733
  • [35] Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI
    Andrews, Anna
    Doctor, Pezad
    Gaur, Lasya
    Greil, F. Gerald
    Hussain, Tarique
    Zou, Qing
    [J]. Mathematical Biosciences and Engineering, 2024, 21 (03) : 3695 - 3712
  • [36] Coronary MRA with 3D undersampled projection reconstruction TrueFISP
    Larson, AC
    Simonetti, OP
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 594 - 601
  • [37] Flow Analysis in Cardiac Chambers Combining Phase Contrast, 3D Tagged and Cine MRI
    Chabiniok, Radomir
    Wong, James
    Giese, Daniel
    Nordsletten, David
    Shi, Wenzhe
    Greil, Gerald
    Rueckert, Daniel
    Razavi, Reza
    Schaeffter, Tobias
    Smith, Nic
    [J]. FUNCTIONAL IMAGING AND MODELING OF THE HEART, 2013, 7945 : 360 - 369
  • [38] Rapid Comprehensive Evaluation of Luminography and Hemodynamic Function with 3D Radially Undersampled Phase Contrast Imaging MRI
    Johnson, Kevin M.
    Francois, Chris
    Lum, Darren
    Bley, Thorsten A.
    Nett, Elisabeth
    Landgraf, Benjamin
    Reeder, Scott B.
    Grist, Thomas M.
    Wieben, Oliver
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4057 - +
  • [39] 3D assessment of respiration induced NSCLC tumor motion
    Forster, K
    Stevens, C
    Kitamura, K
    Starkschall, G
    Liu, H
    Liao, Z
    Chang, J
    Cox, J
    Jeter, M
    Guerrero, T
    Komaki, R
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1364 - 1364
  • [40] 3D motion validation with clinically used cine-MRI and an MR-LINAC phantom
    Dolde, K.
    Schneider, S.
    Pfaffenberger, A.
    Hoffmann, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S511 - S512