Undersampled Cine 3D tagging for rapid assessment of cardiac motion

被引:13
|
作者
Stoeck, Christian T. [1 ,2 ]
Manka, Robert [1 ,2 ,3 ]
Boesiger, Peter [1 ,2 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, CH-8092 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Cardiol, CH-8091 Zurich, Switzerland
[4] Kings Coll London, London, England
基金
瑞士国家科学基金会;
关键词
Motion analysis; Myocardial tagging; k-t undersampling; Principal component analysis; Image reconstruction; K-T BLAST; MAGNETIC-RESONANCE; MYOCARDIAL-PERFUSION; SPATIAL-RESOLUTION; RESPIRATORY MOTION; AORTIC-STENOSIS; DYNAMIC MRI; DENSE MRI; TRACKING; CONTRAST;
D O I
10.1186/1532-429X-14-60
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. Methods: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. Results: In computer simulations, the error for circumferential shortening was 2.8 +/- 2.3% and 2.7 +/- 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 +/- 1.9% and 3.0 +/- 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of -0.14 +/- 5.18% and 0.71 +/- 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 +/- 1.8 and 0.73 +/- 1.67 for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced ( p < 0.002 for all patients) in regions with late gadolinium enhancement. Conclusion: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction
    Odille, Freddy
    Bustin, Aurelien
    Liu, Shufang
    Chen, Bailiang
    Vuissoz, Pierre-Andre
    Felblinger, Jacques
    Bonnemains, Laurent
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2665 - 2675
  • [22] Oblique 3D MRI tags for the estimation of true 3D cardiac motion parameters
    Shimizu, Yu
    Amano, Akira
    Matsuda, Tetsuya
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (08): : 905 - 921
  • [23] Oblique 3D MRI tags for the estimation of true 3D cardiac motion parameters
    Yu Shimizu
    Akira Amano
    Tetsuya Matsuda
    [J]. The International Journal of Cardiovascular Imaging, 2010, 26 : 905 - 921
  • [24] Flow Imaging: Cardiac Applications of 3D Cine Phase-Contrast MRI
    Ebbers T.
    [J]. Current Cardiovascular Imaging Reports, 2011, 4 (2) : 127 - 133
  • [25] Accelerating cardiac Cine 3D Imaging using k-t BLAST
    Kozerke, S
    Tsao, J
    Razavi, R
    Boesiger, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 19 - 26
  • [26] Simultaneous acquisition of MRI and PET cardiac cine 3D images at 9.4 Tesla
    Smith S.D.
    Maramraju S.H.
    Southekal S.
    Ravindranath B.
    Krishnamoorthy S.
    Purschke M.
    Junnarkar S.
    Rescia S.
    Schulz D.
    Woody C.
    Stoll S.
    Vaska P.
    Carrion J.
    Schlyer D.
    Benveniste H.
    [J]. Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [27] 3D FUSION OF CINE AND LATE-ENHANCED CARDIAC MAGNETIC RESONANCE IMAGES
    Cordero-Grande, L.
    Merino-Caviedes, S.
    Alba, X.
    Figueras i Ventura, R. M.
    Frangi, A. F.
    Alberola-Lopez, C.
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 286 - 289
  • [28] Automatic cardiac region-of-interest computation in cine 3D structural MRI
    Cocosco, CA
    Netsch, T
    Sénégas, J
    Bystrov, D
    Niessen, WJ
    Viergever, MA
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1126 - 1131
  • [29] Multi-Device Parallel MRI Reconstruction: Efficient Partitioning for Undersampled 5D Cardiac CINE
    Lopez-Ales, Emilio
    Menchon-Lara, Rosa-Maria
    Simmross-Wattenberg, Federico
    Rodriguez-Cayetano, Manuel
    Martin-Fernandez, Marcos
    Alberola-Lopez, Carlos
    [J]. SENSORS, 2024, 24 (04)
  • [30] A qualitative and quantitative assessment of cardiac cine Phase contrast MRI: comparison of image quality between 2D and 3D acquisition
    Munemura Suzuki
    Takahiko Nakazono
    Ken Yamaguchi
    Kiyoshi Dogomori
    Yoshiaki Komori
    Norihiko Kotooka
    Koichi Node
    Hiroyuki Irie
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)