Undersampled Cine 3D tagging for rapid assessment of cardiac motion

被引:13
|
作者
Stoeck, Christian T. [1 ,2 ]
Manka, Robert [1 ,2 ,3 ]
Boesiger, Peter [1 ,2 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, CH-8092 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Cardiol, CH-8091 Zurich, Switzerland
[4] Kings Coll London, London, England
基金
瑞士国家科学基金会;
关键词
Motion analysis; Myocardial tagging; k-t undersampling; Principal component analysis; Image reconstruction; K-T BLAST; MAGNETIC-RESONANCE; MYOCARDIAL-PERFUSION; SPATIAL-RESOLUTION; RESPIRATORY MOTION; AORTIC-STENOSIS; DYNAMIC MRI; DENSE MRI; TRACKING; CONTRAST;
D O I
10.1186/1532-429X-14-60
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. Methods: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. Results: In computer simulations, the error for circumferential shortening was 2.8 +/- 2.3% and 2.7 +/- 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 +/- 1.9% and 3.0 +/- 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of -0.14 +/- 5.18% and 0.71 +/- 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 +/- 1.8 and 0.73 +/- 1.67 for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced ( p < 0.002 for all patients) in regions with late gadolinium enhancement. Conclusion: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Undersampled Cine 3D tagging for rapid assessment of cardiac motion
    Christian T Stoeck
    Robert Manka
    Peter Boesiger
    Sebastian Kozerke
    [J]. Journal of Cardiovascular Magnetic Resonance, 14
  • [2] A rapid 3D cine MR sequence for cardiac imaging
    Alley, MT
    Shifrin, RY
    Pelc, NJ
    Herfkens, RJ
    [J]. RADIOLOGY, 1997, 205 : 303 - 303
  • [3] Automated cardiac motion estimation from 3D Cine DENSE MRI
    Andrew D Gilliam
    Xiaodong Zhong
    Frederick H Epstein
    [J]. Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [4] Extending Cardiac Functional Assessment with Respiratory-Resolved 3D Cine MRI
    Jing Liu
    Yan Wang
    Zhaoying Wen
    Li Feng
    Ana Paula Santos Lima
    Vaikom S. Mahadevan
    Ann Bolger
    David Saloner
    Karen Ordovas
    [J]. Scientific Reports, 9
  • [5] Fast 3D cardiac cine MR imaging
    Alley, MT
    Napel, S
    Amano, Y
    Paik, DS
    Shifrin, RY
    Shimakawa, A
    Pelc, NJ
    Herfkens, RJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (05): : 751 - 755
  • [6] Extending Cardiac Functional Assessment with Respiratory-Resolved 3D Cine MRI
    Liu, Jing
    Wang, Yan
    Wen, Zhaoying
    Feng, Li
    Lima, Ana Paula Santos
    Mahadevan, Vaikom S.
    Bolger, Ann
    Saloner, David
    Ordovas, Karen
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [7] Precision assessment of bowel motion quantification using 3D cine-MRI for radiotherapy
    Barten, D. L. J.
    van Kesteren, Z.
    Laan, J. J.
    Dassen, M. G.
    Westerveld, G. H.
    Pieters, B. R.
    de Jonge, C. S.
    Stoker, J.
    Bel, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [8] Reconstruction of 3D Dense Cardiac Motion Field from Cine and Tagged Magnetic Resonance Images
    Teo, Soo-Kng
    Parimal, Sarayu
    Gobeawan, Like
    Sampath, Smita
    Chin, Chih-Liang
    Su, Yi
    [J]. 2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 489 - 492
  • [9] 3D Tongue Motion from Tagged and Cine MR Images
    Xing, Fangxu
    Woo, Jonghye
    Murano, Emi Z.
    Lee, Junghoon
    Stone, Maureen
    Prince, Jerry L.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 41 - 48
  • [10] Accelerated Reconstruction of Highly Undersampled 3D Cardiac MRI Image Navigators
    Guo, Xinrui
    Sheagren, Calder D.
    Patel, Jaykumar H.
    Li, Liwen
    Wright, Graham A.
    Guo, Fumin
    [J]. MEDICAL IMAGING 2024: IMAGE PROCESSING, 2024, 12926