Beat-to-beat Intervals of Speckle & Intensity-based Optical Plethysmograms compared to Electrocardiogram

被引:6
|
作者
Olazabal, Jorge Herranz [1 ,2 ]
Wieringa, Fokko [3 ,4 ]
Hermeling, Evelien [3 ]
Van Hoof, Christopher [1 ,2 ]
机构
[1] IMEC, Leuven, Belgium
[2] Katholieke Univ Leuven, Leuven, Belgium
[3] Imec NL, Eindhoven, Netherlands
[4] Univ Med Ctr Utrecht, Utrecht, Netherlands
来源
2021 COMPUTING IN CARDIOLOGY (CINC) | 2021年
关键词
SPECKLEPLETHYSMOGRAPHIC SPG;
D O I
10.23919/CinC53138.2021.9662819
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study evaluates video sequences obtained by a form of laser speckle imaging (LSI) - referred to as remote camera-derived Speckleplethysmography (rSPG) - in comparison to common clinical parameters (PPG & ECG). For 9 human subjects we illuminated the index finger with a laser (639 nm, 10 mW, spot diameter 5.6 mm), captured video streams with a camera (Basler acA2000-340km, 25 cm distance, 100 fps) and evaluated spatial variations in the captured speckle patterns. We simultaneously collected contact-mode transmissive photoplethysmography (PPG) and electrocardiography (ECG) signals. We derived beat-to-beat (b-2-b) intervals from both rSPG and contact-mode PPG signals and compared both with the ECG R-R intervals `goldstandard' (3234 heart-cycles in total). B-2-b interval error distributions of rSPG vs contact PPG showed: mean absolute deviation 10.4 vs 14.2 ms; standard deviation 25.2 vs 30.1 ms. Two-sample F-test revealed significantly different variances (p < 0.001, 99% confidence). Additional Levene's test: F (1, 6468) = 37.602, p = 0. This study demonstrates that contactless cameraderived rSPG can obtain b-2-b intervals at least as good as routine clinical contact-mode transmissive finger clip PPG. This might enable innovative applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] COMMUNITY STRUCTURE IN NETWORK REPRESENTATION OF INCREMENTS IN BEAT-TO-BEAT TIME INTERVALS OF THE HEART IN PATIENTS AFTER HEART TRANSPLANTATION
    Makowiec, Danuta
    Struzik, Zbigniew
    Graff, Beata
    Wdowczyk-Szulc, Joanna
    Zarczynska-Buchowiecka, Marta
    Kryszewski, Stanislaw
    ACTA PHYSICA POLONICA B, 2013, 44 (05): : 1219 - 1233
  • [42] The coherence spectrum for quantifying beat-to-beat adaptation of RT intervals to heart rate in normal subjects and in postinfarction patients
    Sosnowski, M
    Czyz, Z
    Leski, J
    Petelenz, T
    Tendera, M
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 669 - 672
  • [43] Beat-to-Beat Patterning of Sinus Rhythm Reveals Non-linear Rhythm in the Dog Compared to the Human
    Meise, N. Sydney
    Flanders, Wyatt H.
    Pariaut, Romain
    FRONTIERS IN PHYSIOLOGY, 2020, 10
  • [44] Determination of fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram
    Jezewski, Janusz
    Matonia, Adam
    Kupka, Tomasz
    Roj, Dawid
    Czabanski, Robert
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (05): : 383 - 394
  • [45] Absolute beat-to-beat variability and instability parameters of ECG intervals: biomarkers for predicting ischaemia-induced ventricular fibrillation
    Sarusi, Annamaria
    Rarosi, Ferenc
    Szucs, Monika
    Csik, Norbert
    Farkas, Attila S.
    Papp, Julius Gy
    Varro, Andras
    Forster, Tamas
    Curtis, Michael J.
    Farkas, Andras
    BRITISH JOURNAL OF PHARMACOLOGY, 2014, 171 (07) : 1772 - 1782
  • [46] Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement
    Wang, Ting-Wei
    Lin, Shien-Fong
    SENSORS, 2020, 20 (03)
  • [47] A Correlation-Based Algorithm for Beat-to-Beat Heart Rate Estimation from Ballistocardiograms
    Wen, Xin
    Huang, Yanqi
    Wu, Xiaomei
    Zhang, Biyong
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6355 - 6358
  • [48] Unconstrained Accurate Beat-to-beat Heart Rate Extraction Based on Piezoelectric Ceramics Sensor
    Fang Zhen
    Bai Zhongrui
    Chen Xianxiang
    Xia Pan
    He Zhengling
    Zhao Rongjian
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2021, 43 (05) : 1472 - 1479
  • [49] Beat-to-beat estimate of fetal cardiac time intervals using magnetocardiography: longitudinal charts of normality ranges and individual trends
    Comani, S
    Liberati, M
    Mantini, D
    Merlino, B
    Alleva, G
    Gabriele, E
    Di Luzio, S
    Romani, GL
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2005, 84 (12) : 1175 - 1180
  • [50] The Use of Beat-to-Beat Electrocardiogram Analysis to Distinguish QT/QTc Interval Changes Caused by Moxifloxacin From Those Caused by Vardenafil
    Fossa, A. A.
    Langdon, G.
    Couderc, J-P
    Zhou, M.
    Darpo, B.
    Wilson, F.
    Wallis, R.
    Davis, J. D.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2011, 90 (03) : 449 - 454