Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines

被引:0
|
作者
Decat, G [1 ]
Van Tongerloo, J [1 ]
机构
[1] Vlaamse Instelling Technol Onderzoek, Lab Electromagnet Smog, Ctr Remote Sensing & Atmospher Proc, CETAP, B-2400 Mol, Belgium
关键词
50 Hz magnetic field; background magnetic field; exposure time integrals; exposure standards and guidelines; overhead transmission line;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 mu T to 4.5 mu T.. The maximum value was at least 20 times weaker than the 100 mu T exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 mu T of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 mu T cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 mu T level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 mu T background value.
引用
收藏
页码:341 / 351
页数:11
相关论文
共 50 条
  • [41] Lightning and high-voltage power transmission lines
    不详
    NATURE, 1934, 134 : 223 - 224
  • [42] The influence of sag in the electric field calculation around high voltage overhead transmission lines
    Amiri, R.
    Hadi, H.
    Marich, M.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 206 - 209
  • [43] Electric Field of High Voltage Direct Current Overhead Transmission Lines with Covered Conductors
    Jiang, Yuze
    Li, Lefeng
    Jiang, Diwen
    Liang, Zhenguang
    Li, Fangwei
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 110 - 113
  • [44] An Introduction to Horizontal Directional Drill Installation of High-Voltage Transmission Lines and Other Duct Banks IMPROVING ON CONVENTIONAL OVERHEAD TRANSMISSION LINES
    Smith III, Arthur J. J.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2023, 29 (03) : 23 - 35
  • [45] Ultrasensitive lightweight magnetic probe for non-destructive inspection of high-voltage overhead lines
    Brahim, Yahya Iben
    Bellemare, Jonathan
    Rousseau, Gilles
    Pouliot, Nicolas
    Menard, David
    Sirois, Frederic
    NDT & E INTERNATIONAL, 2023, 134
  • [46] A high-voltage power supply operating under a magnetic field
    Shikaze, Y
    Imori, M
    Fuke, H
    Matsumoto, H
    Taniguchi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 535 - 540
  • [47] THE LIGHTNING PROTECTION OF HIGH-VOLTAGE OVERHEAD TRANSMISSION AND DISTRIBUTION SYSTEMS
    LACEY, HM
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1949, 96 (50): : 287 - 299
  • [48] The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells
    Pang Xiao-feng
    Yuan Ping
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2997 - 3000
  • [49] Design of a galvanic monitoring module for high-voltage overhead transmission lines based on the fusion of multi-mode spatial distance weights
    Yuan J.
    Pan G.
    Xie J.
    Chen X.
    Guo J.
    Liu X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (24): : 173 - 179
  • [50] PRINCIPLES OF GROUND RELAYING FOR HIGH-VOLTAGE AND EXTRA HIGH-VOLTAGE TRANSMISSION-LINES
    GRIFFIN, CH