Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines

被引:0
|
作者
Decat, G [1 ]
Van Tongerloo, J [1 ]
机构
[1] Vlaamse Instelling Technol Onderzoek, Lab Electromagnet Smog, Ctr Remote Sensing & Atmospher Proc, CETAP, B-2400 Mol, Belgium
关键词
50 Hz magnetic field; background magnetic field; exposure time integrals; exposure standards and guidelines; overhead transmission line;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 mu T to 4.5 mu T.. The maximum value was at least 20 times weaker than the 100 mu T exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 mu T of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 mu T cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 mu T level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 mu T background value.
引用
收藏
页码:341 / 351
页数:11
相关论文
共 50 条
  • [21] FACTORS INFLUENCING DEVELOPMENT, PLANNING AND DESIGN OF HIGH-VOLTAGE OVERHEAD TRANSMISSION-LINES
    MORGENSTERN, W
    ENERGIETECHNIK, 1978, 28 (08): : 299 - 300
  • [22] Averaged magnetic field intensity in the vicinity of overhead high voltage lines
    Jaworski, Marek
    Szuba, Marek
    Grycan, Wiktoria
    2018 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2018,
  • [23] Glioblastoma Near High-voltage Overhead Power Lines
    Bekar, Ahmet
    Taskapilioglu, M. Ozgur
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2014, 31 (04): : 846 - 847
  • [24] Methods of electric field intensity reduction under overhead electric power transmission lines of high voltage
    Oleszkiewicz, Pawel
    Nadolny, Zbigniew
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 196 - 199
  • [25] A Feasibility Study on Autonomous Online Condition Monitoring of High-Voltage Overhead Power Lines
    Zangl, Hubert
    Bretterklieber, Thomas
    Brasseur, Georg
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1789 - 1796
  • [26] Energy harvesting for a wireless-monitoring system of overhead high-voltage power lines
    Zhao, Xinming
    Keutel, Thomas
    Baldauf, Marc
    Kanoun, Olfa
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (02) : 101 - 107
  • [27] Monitoring and Risk Assessment of Wildfires in the Corridors of High-Voltage Transmission Lines
    Liang, Yu
    Zhou, Lawu
    Chen, Jie
    Huang, Yong
    Wei, Ruizeng
    Zhou, Enze
    IEEE ACCESS, 2020, 8 : 170057 - 170069
  • [28] Automated monitoring of high-voltage transmission lines based on machine vision
    Wang M.
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [29] Variations of proliferation states of cells under action of electromagnetic field of high-voltage transmission lines
    Pang Xiao-feng
    Liu lewei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1145 - 1148
  • [30] Analysis of electric field distribution around the high-voltage overhead transmission lines with an ADSS fiber-optic cable
    Florkowska, B
    Jackowicz-Korczynski, A
    Timler, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (03) : 1183 - 1189