This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 mu T to 4.5 mu T.. The maximum value was at least 20 times weaker than the 100 mu T exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 mu T of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 mu T cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 mu T level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 mu T background value.
引用
收藏
页码:341 / 351
页数:11
相关论文
共 50 条
  • [1] Magnetic field monitored in houses under 50 Hz high-voltage transmission lines of 70, 150, 220 & 380 kV
    Decat, G
    Van Tongerloo, J
    AIR POLLUTION VI, 1998, 6 : 237 - 246
  • [2] 50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation
    Deprez, Kenneth
    Van de Steene, Tom
    Verloock, Leen
    Tanghe, Emmeric
    Gomme, Liesbeth
    Verlaek, Mart
    Goethals, Michel
    van Campenhout, Karen
    Plets, David
    Joseph, Wout
    SENSORS, 2024, 24 (16)
  • [3] Air ion concentrations under overhead high-voltage transmission lines
    Jayaratne, E. R.
    J-Fatokun, F. O.
    Morawska, L.
    ATMOSPHERIC ENVIRONMENT, 2008, 42 (08) : 1846 - 1856
  • [4] Noncontact Operation-State Monitoring Technology Based on Magnetic-Field Sensing for Overhead High-Voltage Transmission Lines
    Sun, Xun
    Huang, Qi
    Hou, Yunhe
    Jiang, Lijun
    Pong, Philips
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [5] Noncontact Operation-State Monitoring Technology Based on Magnetic-Field Sensing for Overhead High-Voltage Transmission Lines
    Sun, Xu
    Huang, Qi
    Hou, Yunhe
    Jiang, Lijun
    Pong, Philip W. T.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2145 - 2153
  • [6] DANGER OVERHEAD + HIGH-VOLTAGE TRANSMISSION-LINES
    DIAMOND, S
    OMNI, 1978, 1 (03) : 37 - 37
  • [7] IMPACTS OF OVERHEAD HIGH-VOLTAGE TRANSMISSION-LINES
    COLEMAN, DM
    JOURNAL OF ENVIRONMENTAL SYSTEMS, 1981, 10 (04): : 283 - 304
  • [8] Mitigation of 50 Hz Magnetic Field Produced by an Overhead Transmission Line
    Ippolito, Mariano Giuseppe
    Puccio, Andrea
    Ala, Guido
    Ganci, Salvatore
    Filippone, Giovanni
    2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [9] MAINTENANCE STRATEGY FOR HIGH-VOLTAGE OVERHEAD TRANSMISSION-LINES
    SPIESS, K
    KRUMM, M
    ENERGIETECHNIK, 1978, 28 (08): : 304 - 306
  • [10] Maintenance Strategy for High-Voltage Overhead Transmission Lines.
    Spiess, Klaus
    Krumm, Michael
    1600, (28):