The aim of this study was to determine guidelines for estimating lotto-lot differences in the potency of calibrator materials or batches of standards for radioimmunoassays. Thirty one lots of standards for thirteen different analytes were compared to the previous lot for that analyte with the relative potency computed by nine different methods. Assays were performed manually. The nine different calculation methods included non-simultaneous fitting of pairs of standard curves, full or partial simultaneous fitting, and least squares or robust minimisation. The simultaneous methods were found superior to the non-simultaneous in minimising the variance of the relative potency estimates, while robust fitting procedures did not result in a lower variance than least-squares minimisation. The root mean square coefficient of variation for the simultaneous estimation of the relative potency by least squares was 6.1 %. On this basis, it is recommended that relative potency estimations in radioimmunoassay be based on at least eight independent pair-wise standard curve comparisons. Additional guidelines for preparing and comparing batches of standards are also given.
引用
收藏
页码:243 / 263
页数:21
相关论文
共 50 条
  • [21] The impact of lot-to-lot and wafer-to-wafer variations on SPC
    Nurani, RK
    Shanthikumar, JG
    1997 2ND INTERNATIONAL WORKSHOP ON STATISTICAL METROLOGY, 1997, : 110 - 110
  • [22] The impact of lot-to-lot and wafer-to-wafer variations on SPC
    Nurani, RK
    Shanthikumar, JG
    1997 IEEE INTERNATIONAL SYMPOSIUM ON SEMICONDUCTOR MANUFACTURING CONFERENCE PROCEEDINGS, 1997, : P69 - P72
  • [23] Lot-to-Lot Variance in Immunoassays-Causes, Consequences, and Solutions
    Luo, Yunyun
    Pehrsson, Martin
    Langholm, Lasse
    Karsdal, Morten
    Bay-Jensen, Anne-Christine
    Sun, Shu
    DIAGNOSTICS, 2023, 13 (11)
  • [24] LOT-TO-LOT VARIABILITY OF 2 RHEUMATOID-FACTOR TESTS
    KILBOURN, JP
    JOURNAL OF THE AMERICAN MEDICAL TECHNOLOGISTS, 1977, 39 (05): : 237 - 238
  • [25] Performance evaluation and lot-to-lot consistency of the Abbott Architects® Progesterone assay
    Rufo, G
    Brookhart, P
    Barnes, W
    Frels, M
    Sheu, M
    White, M
    Chan, S
    Lauren, L
    McHale, P
    Bartko, K
    CLINICA CHIMICA ACTA, 2005, 355 : S271 - S272
  • [26] Estimating Drug Shelf-life with Unknown Lot-to-lot Variability
    Srimaneekarn, N.
    Kiatsupaibul, S.
    Hayter, A. J.
    Liu, W.
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2015, 44 (08) : 2195 - 2207
  • [27] Detection of lot-to-lot variations in the amorphous microstructure of lyophilized protein formulations
    Hirakura, Yutaka
    Yamaguchi, Hideto
    Mizuno, Masayasu
    Miyanishi, Hideo
    Ueda, Satoshi
    Kitamura, Satoshi
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 340 (1-2) : 34 - 41
  • [28] Analysis of Reagent Lot-to-Lot Comparability Tests in Five Immunoassay Items
    Kim, Hyun Soo
    Kang, Hee Jung
    Whang, Dong Hee
    Lee, Seong Gyu
    Park, Min Jeong
    Park, Ji-Young
    Lee, Kyu Man
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2012, 42 (02): : 165 - 173
  • [29] BETA-AMYLOID PEPTIDE INVITRO TOXICITY - LOT-TO-LOT VARIABILITY
    MAY, PC
    GITTER, BD
    WATERS, DC
    SIMMONS, LK
    BECKER, GW
    SMALL, JS
    ROBISON, PM
    NEUROBIOLOGY OF AGING, 1992, 13 (05) : 605 - 607
  • [30] Cell Culture Media Lot-To-Lot Variability: Can We Control It?
    Piras, Graziella
    BIOPHARM INTERNATIONAL, 2017, 30 (10) : 48 - 49