Overloading of the second-dimension column in comprehensive two-dimensional gas chromatography

被引:35
|
作者
Harynuk, J
Górecki, T
de Zeeuw, J
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Varian Inc, NL-4330 EA Middelburg, Netherlands
关键词
comprehensive two-dimensional gas chromatography; GC x GC; overloading; column diameter;
D O I
10.1016/j.chroma.2004.11.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional gas chromatography (GC x GC) is based on a coupling of two GC columns of different characteristics by means of a device that allows portions of the effluent from the primary column to be injected onto the second dimension column for an additional separation. The time available for the separation in the second-dimension column is very short. Thus, this separation should be very efficient. The vast majority of GC x GC practitioners use very narrow bore columns for the second dimension. While this approach is justified in principle, if peaks in the second dimension overload this column, its peak capacity is severely reduced. A series of second-dimension columns of varying internal diameters, but similar phase ratios, were used to study these effects. The results indicate that 250 mu m columns often provide comparable second dimension peak widths to 100 mu m columns, while at the same time being less prone to overloading, indicating that they may often be a better choice than smaller diameter columns in the second dimension of GC x GC systems. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 50 条
  • [41] Modulators for comprehensive two-dimensional gas chromatography
    Tranchida, Peter Quinto
    Purcaro, Giorgia
    Dugo, Paola
    Mondello, Luigi
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) : 1437 - 1461
  • [42] Parallel comprehensive two-dimensional gas chromatography
    Yan, DanDan
    Tedone, Laura
    Koutoulis, Anthony
    Whittock, Simon P.
    Shellie, Robert A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1524 : 202 - 209
  • [43] Comprehensive two-dimensional gas chromatography in metabolomics
    Martin F. Almstetter
    Peter J. Oefner
    Katja Dettmer
    [J]. Analytical and Bioanalytical Chemistry, 2012, 402 : 1993 - 2013
  • [44] Comprehensive two-dimensional gas chromatography.
    Phillips, JB
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U200 - U200
  • [45] Comprehensive two-dimensional gas chromatography in metabolomics
    Almstetter, Martin F.
    Oefner, Peter J.
    Dettmer, Katja
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) : 1993 - 2013
  • [46] A review of two-dimensional liquid chromatography approaches using parallel column arrays in the second dimension
    Foster, Samuel W.
    Parker, Deklin
    Kurre, Sangeeta
    Boughton, John
    Stoll, Dwight R.
    Grinias, James P.
    [J]. Analytica Chimica Acta, 2022, 1228
  • [47] A review of two-dimensional liquid chromatography approaches using parallel column arrays in the second dimension
    Foster, Samuel W.
    Parker, Deklin
    Kurre, Sangeeta
    Boughton, John
    Stoll, Dwight R.
    Grinias, James P.
    [J]. ANALYTICA CHIMICA ACTA, 2022, 1228
  • [48] Effects of the gradient profile, sample volume and solvent on the separation in very fast gradients, with special attention to the second-dimension gradient in comprehensive two-dimensional liquid chromatography
    Jandera, Pavel
    Hajek, Tomas
    Cesla, Petr
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (15) : 1995 - 2006
  • [49] Effect of column combinations on two-dimensional separation in comprehensive two-dimensional gas chromatography: Estimation of orthogonality and exploring of mechanism
    Zhu, Shukui
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3312 - 3317
  • [50] Multi-column trajectory to advanced methods in comprehensive two-dimensional gas chromatography
    Nolvachai, Yada
    Kulsing, Chadin
    Sharif, Khan M.
    Wong, Yong Foo
    Chin, Sung-Tong
    Mitrevski, Blagoj
    Marriott, Philip J.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 106 : 11 - 20