Experimental investigation of a novel multi-channel flat plate liquid desiccant dehumidification system

被引:7
|
作者
Sharma, Akash [1 ]
Kaushal, Rajneesh [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Kurukshetra 136119, Haryana, India
关键词
Liquid desiccant; dehumidification; regeneration; effectiveness; moisture absorption rates; AIR-CONDITIONING SYSTEM; NATURAL-GAS DEHYDRATION; MASS-TRANSFER; PERFORMANCE ANALYSIS; PARAMETRIC ANALYSIS; DEHUMIDIFIER/REGENERATOR; LITHIUM;
D O I
10.1080/15567036.2020.1789243
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The continuously growing energy demands for space air conditioning and depletion of conventional energy resources at a fast rate have propagated the need for producing a new and wide range of renewable and sustainable energy technologies. Liquid desiccant dehumidification technologies are the most optimistic approach due to their lower regeneration temperature required, a higher coefficient of performance, and the ability to be used during night hours. The factors responsible for the limited application of these systems are desiccant leakage, corrosion to the fabricating material, and carryover of desiccant droplets with the process air. To overcome these issues, a new multi-channel flat plate liquid desiccant air conditioning system has been developed and experimentally investigated. The performance of the system has been analyzed for the dehumidification and regeneration process. Calcium chloride has been used as a desiccant material with 40% and 35% by wt. concentration. Three sets of velocities of process air have been utilized, i.e., 0.9, 0.7, 0.5 m/s to investigate the system performance. Performance parameters, such as dehumidification rate, regeneration rate, dehumidification, and regeneration effectiveness, have been investigated in the present study. The liquid desiccant dehumidification system investigated in the present study includes a flat plate energy exchanger for heat and mass transfer between ambient moist air and liquid desiccant solution. This system conveys a large interfacial surface area between liquid desiccant solution and process air. Experimental results indicate that, in the dehumidification process, the ambient moist air has been dehumidified and cooled by 5.90 g kg(-1)and 1.4 degrees C, respectively, and dehumidification effectiveness of 0.239 has been achieved for the air velocity of 5 m/s at 40% concentration of the desiccant solution. Regeneration rate and effectiveness have been observed to be 0.014 g s(-1)and 0.323, respectively, for the air velocity of 5 m/s at 35% concentration. The work presented in this study demonstrates the feasibility of the novel multi-layer flat plat liquid desiccant concept and provide growth and development to the liquid desiccant technologies for space air conditioning. Certain issues regarding the mass imbalance in the dehumidification and regeneration processes have been identified to be considered as future scope.
引用
收藏
页码:11148 / 11166
页数:19
相关论文
共 50 条
  • [31] Wetting improvement of plastic working plate for liquid desiccant dehumidification systems
    Qi, Ronghui
    Zhi, Jinghui
    Zhang, Li-zhi
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 3076 - 3081
  • [32] The design and performance improvement of liquid desiccant dehumidification system
    Cihan, Ertugrul
    Kavasogullari, Baris
    Demir, Hasan
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2017, 32 (03): : 709 - 717
  • [33] Improvement of the ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Zhang, Kaisheng
    Yang, Menghao
    Lian, Zhiwei
    ENERGY AND BUILDINGS, 2014, 85 : 145 - 154
  • [34] A MEMBRANE DISTILLATION REGENERATOR IN LIQUID DESICCANT DEHUMIDIFICATION SYSTEM
    Wang Zanshe
    Gu Zhaolin
    Feng Shiyu
    Li Yun
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 346 - 350
  • [35] Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations
    Chen, Ziwei
    Zhu, Jie
    Bai, Hongyu
    ENERGY AND BUILDINGS, 2017, 139 : 665 - 679
  • [36] Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system
    Gao, W. Z.
    Shi, Y. R.
    Cheng, Y. P.
    Sun, W. Z.
    ENERGY AND BUILDINGS, 2013, 61 : 202 - 209
  • [37] Dynamic behaviour simulation of a liquid desiccant dehumidification system
    Kabeel, A. E.
    Khalil, A.
    Elsayed, S. S.
    Alatyar, A. M.
    ENERGY, 2018, 144 : 456 - 471
  • [38] Experimental study on dehumidification/regeneration of liquid desiccant: LiBr solution
    Bouzenada, S.
    Kaabi, A. N.
    Fraikin, L.
    Leonard, A.
    5TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT-2014), THE 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2014), 2014, 32 : 673 - 680
  • [39] Exergy analysis of liquid desiccant dehumidification and cooling system
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    Huagong Xuebao, 2008, SUPPL. (37-42):
  • [40] Experimental investigations on heat and mass transfer performances of a liquid desiccant cooling and dehumidification system
    Ou, Xianhua
    Cai, Wenjian
    He, Xiongxiong
    Zhai, Deqing
    APPLIED ENERGY, 2018, 220 : 164 - 175