Multifaceted bench comparative evaluation of latest intensive care unit ventilators

被引:26
|
作者
Garnier, M. [1 ,5 ]
Quesnel, C. [1 ,5 ]
Fulgencio, J. -P. [1 ]
Degrain, M. [4 ]
Carteaux, G. [8 ]
Bonnet, F. [1 ,5 ]
Similowski, T. [2 ,3 ,5 ,6 ]
Demoule, A. [2 ,3 ,5 ,7 ]
机构
[1] Hop Tenon, Anaesthesiol & Intens Care Dept, F-75020 Paris, France
[2] Grp Hosp Pitie Salpetriere, Med Intens Care Unit, F-75634 Paris, France
[3] Grp Hosp Pitie Salpetriere, Div Resp, F-75634 Paris, France
[4] AP HP, Agence Gen Equipements & Prod Sante, Paris, France
[5] Univ Paris 06, Fac Med Pierre & Marie Curie, Paris, France
[6] Univ Paris 06, ER10, Paris, France
[7] Univ Paris 06, INSERM, U974, Paris, France
[8] Ctr Hosp Albert Chenevier Henri Mondor, AP HP, Med Intens Care Unit, Creteil, France
关键词
bench study; mechanical ventilation; non-invasive ventilation; quality improvement; ventilator performance; RESPIRATORY-DISTRESS-SYNDROME; PRESSURE SUPPORT VENTILATION; END-EXPIRATORY PRESSURE; ACUTE LUNG INJURY; NONINVASIVE VENTILATION; PERFORMANCE-CHARACTERISTICS; ICU VENTILATORS; TIDAL VOLUME; ANESTHESIA VENTILATORS; MECHANICAL VENTILATORS;
D O I
10.1093/bja/aev028
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Independent bench studies using specific ventilation scenarios allow testing of the performance of ventilators in conditions similar to clinical settings. The aims of this study were to determine the accuracy of the latest generation ventilators to deliver chosen parameters in various typical conditions and to provide clinicians with a comprehensive report on their performance. Methods: Thirteen modern intensive care unit ventilators were evaluated on the ASL5000 test lung with and without leakage for: (i) accuracy to deliver exact tidal volume (VT) and PEEP in assist-control ventilation (ACV); (ii) performance of trigger and pressurization in pressure support ventilation (PSV); and (iii) quality of non-invasive ventilation algorithms. Results: In ACV, only six ventilators delivered an accurate VT and nine an accurate PEEP. Eleven devices failed to compensate VT and four the PEEP in leakage conditions. Inspiratory delays differed significantly among ventilators in invasive PSV (range 75-149 ms, P=0.03) and non-invasive PSV (range 78-165 ms, P<0.001). The percentage of the ideal curve (concomitantly evaluating the pressurization speed and the levels of pressure reached) also differed significantly (range 57-86% for invasive PSV, P=0.04; and 60-90% for non-invasive PSV, P<0.001). Non-invasive ventilation algorithms efficiently prevented the decrease in pressurization capacities and PEEP levels induced by leaks in, respectively, 10 and 12 out of the 13 ventilators. Conclusions: We observed real heterogeneity of performance amongst the latest generation of intensive care unit ventilators. Although non-invasive ventilation algorithms appear to maintain adequate pressurization efficiently in the case of leakage, basic functions, such as delivered VT in ACV and pressurization in PSV, are often less reliable than the values displayed by the device suggest.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [21] Public Preferences for Allocating Ventilators in an Intensive Care Unit: A Discrete Choice Experiment
    Richard Norman
    Suzanne Robinson
    Helen Dickinson
    Iestyn Williams
    Elena Meshcheriakova
    Kathleen Manipis
    Matthew Anstey
    [J]. The Patient - Patient-Centered Outcomes Research, 2021, 14 : 319 - 330
  • [22] COMPARATIVE EVALUATION OF SIX CARDIAC OUTPUT METHODS IN SURGICAL INTENSIVE CARE UNIT
    Bart, F.
    Dereu, D.
    Lukaszewicz, A. C.
    Mateo, J.
    Payen, D.
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 : S97 - S97
  • [23] An Internet of Things-based Predictive Maintenance Architecture for Intensive Care Unit Ventilators
    Manchadi, Oumaima
    Ben-Bouazza, Fatima-Ezzahraa
    Dehbi, Zineb El Otmani
    Edder, Aymane
    Tafala, Idriss
    Et-Taoussi, Mehdi
    Jioudi, Bassma
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (02) : 932 - 943
  • [24] Intensive care unit trainee evaluation
    Powner, DJ
    Rieker, JP
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (11) : 1772 - 1773
  • [25] Bench-to-bedside review: Candida infections in the intensive care unit
    Marie Méan
    Oscar Marchetti
    Thierry Calandra
    [J]. Critical Care, 12
  • [26] Evaluation of Nurses' Workload in the Intensive Care Unit, Neonatal Intensive Care Unit and Coronary Care Unit: An Analytical Study
    Azadi, Maryam
    Azimian, Jalil
    Mafi, Maryam
    Rashvand, Farnoosh
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (11) : LC5 - LC7
  • [27] Bench-to-bedside review:: Candida infections in the intensive care unit
    Mean, Marie
    Marchetti, Oscar
    Calandra, Thierry
    [J]. CRITICAL CARE, 2008, 12 (01):
  • [28] PROSPECTIVE EVALUATION OF A MULTIFACETED INTERVENTION TO IMPROVE OUTCOMES IN INTENSIVE CARE
    Dykes, Patricia
    Massaro, Anthony
    Rozenblum, Ronen
    Dalal, Anuj
    Collins, Sarah
    Gazarian, Priscilla
    Lipsitz, Stuart
    Bates, David
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [29] Evaluation of the user-friendliness of seven new generation intensive care ventilators
    Vignaux, Laurence
    Tassaux, Didier
    Jolliet, Philippe
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (10) : 1687 - 1691
  • [30] Evaluation of the user-friendliness of seven new generation intensive care ventilators
    Laurence Vignaux
    Didier Tassaux
    Philippe Jolliet
    [J]. Intensive Care Medicine, 2009, 35 : 1687 - 1691