4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy

被引:50
|
作者
Engwall, Erik [1 ]
Fredriksson, Albin [1 ]
Glimelius, Lars [1 ]
机构
[1] RaySearch Labs, Sveavagen 44, SE-11134 Stockholm, Sweden
关键词
4D optimization; interplay effect; motion mitigation; proton therapy; rescanning; robust optimization; CELL LUNG-CANCER; DOSE CALCULATION ACCURACY; RESPIRATORY MOTION; PARTICLE THERAPY; RANGE UNCERTAINTIES; MOVING TARGETS; STAGE-I; RADIOTHERAPY; SENSITIVITY; MITIGATION;
D O I
10.1002/mp.13094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeInterplay effects in proton radiotherapy can create large distortions in the dose distribution and severely degrade the plan quality. Standard methods to mitigate these effects include abdominal compression, gating, and rescanning. We propose a new method to include the time structures of the delivery and organ motion in the framework of four-dimensional (4D) robust optimization to generate plans that are robust against interplay effects. MethodsThe method considers multiple scenarios reflecting the uncertainties in the delivery and in the organ motion. In each scenario, the pencil beam scanning spots are distributed to different phases of the breathing cycle according to each individual spot time stamp, and a partial beam dose is calculated for each phase. The partial beam doses are accumulated on a reference phase through deformable image registrations. Minimax optimization is performed to take all scenarios into account simultaneously. For simplicity, the uncertainties in this proof of concept study are limited to variations in the breathing pattern. The method is evaluated for three different nonsmall cell lung cancer patients and compared to plans using conventional 4D robust optimization both with and without rescanning. We assess the ability of the method to mitigate distortions from the interplay effect over multiple evaluation scenarios using 4D dose calculations. This interplay evaluation is performed in an experimentally validated framework, which is independent of the optimization in the plan generation step. ResultsFor the three studied patients, 4D optimization including time structures is efficient, especially for large tumor motions, where rescanning of conventional 4D robustly optimized plans is not sufficient to mitigate the interplay effect. The most efficient approach of the new method is achieved when it is combined with rescanning. For the patient with the largest motion, the mean V95% is 99.2% and mean V107% is 3.65% for the best rescanned 4D plan optimized with time structure. This can be compared to conventional 4D optimized plans with mean V95% of 92.7% and mean V107% of 13.1%. ConclusionsThe current study shows the potential of reducing interplay effects in proton pencil beam scanning radiotherapy by incorporating organ motion and delivery characteristics in a 4D robust optimization.
引用
收藏
页码:4020 / 4029
页数:10
相关论文
共 50 条
  • [1] Implementation of 4D proton therapy treatments with pencil beam scanning (PBS)
    Fracchiolla, F.
    Dionisi, F.
    Hild, S.
    Giacomelli, I.
    Lorentini, S.
    Engwall, E.
    Esposito, P. G.
    Amichetti, M.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1110 - S1111
  • [2] Comparison of Pencil Beam Scanning Proton Therapy Planning with 3D and 4D Robust Optimization Versus Photon IMRT for Lung Cancer
    Huang, M.
    Torok, J.
    Chen, H.
    Lin, Y.
    Ren, L.
    Blakey, M.
    Xiao, Y.
    Kassaee, A.
    Kelsey, C.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E728 - E728
  • [3] Investigating volumetric repainting to mitigate interplay effect on 4D robustly optimized lung cancer plans in pencil beam scanning proton therapy
    Rana, Suresh
    Rosenfeld, Anatoly B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 107 - 118
  • [4] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [5] Robust Proton Pencil Beam Scanning Treatment Planning for Rectal Cancer Radiation Therapy
    Kiely, Janid Patricia Blanco
    White, Benjamin M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 208 - 215
  • [6] Robust optimization for IMPT of pencil-beam scanning proton therapy for prostate cancer
    Brouwer, C. L.
    Matysiak, W. P.
    Klinker, P.
    Spijkerman-Bergsma, M.
    Hammer, C.
    Van den Bergh, A. C. M.
    Langendijk, J. A.
    Scandurra, D.
    Korevaar, E. W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S835 - S836
  • [7] Timing Features of 4D Detector and Pencil Beam Scanning Proton Therapy Can Improve WET Map Accuracy with Deep CNN
    Chang, C.
    Zhou, S.
    Zhou, J.
    Yang, X.
    Zhang, T.
    Lin, L.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E866 - E866
  • [8] Exploring the Capability of 4D Optimization for Moving Tumour Treatments Using Pencil Beam Scanning (PBS) Proton Therapy: A Benchmarking Study
    Zhang, Ye
    Tiberio, P.
    Huth, I.
    Weber, D.
    Lomax, A.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E432 - E432
  • [9] 4D evaluation of proton pencil beam scanning and double scattering for hepatocellular carcinoma
    Pfeiler, T.
    Baeumer, C.
    Blanck, O.
    Chan, M.
    Engwall, E.
    Geismar, D.
    Peters, S.
    Spaan, B.
    Wulff, J.
    Timmermann, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1105 - S1106
  • [10] Technical Note: Investigating interplay effects in pencil beam scanning proton therapy with a 4D XCAT phantom within the RayStation treatment planning system
    den Boer, Erik
    Wulff, Joerg
    Maeder, UIf
    Engwall, Erik
    Baeumer, Christian
    Perko, Zoltan
    Timmermann, Beate
    [J]. MEDICAL PHYSICS, 2021, 48 (03) : 1448 - 1455