Revision of the well fixed Birmingham Hip Resurfacing acetabular component - Results using a novel device

被引:0
|
作者
Sandiford, Nemandra A.
Muirhead-Allwood, Sarah
Skinner, John
机构
[1] London Hip Unit, London, England
[2] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
来源
ACTA ORTHOPAEDICA BELGICA | 2012年 / 78卷 / 01期
关键词
hip resurfacing; revision; well fixed; acetabular cup; REMOVAL; ARTHROPLASTY;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision of well fixed uncemented Birmingham Hip Resurfacing (BHR) acetabular components is challenging due to their dual radius design and their stabilising fins. These features preclude use of the standard Explant (TM) device. We investigated a novel device designed to simplify revision of this socket. This prospective study included 6 male and 14 female patients. The reasons for revision, technique of revision and the scientific basis for use of this device are discussed. The sizes of revised and implanted components were measured and the amount of bone loss was calculated. Patient satisfaction was assessed as well as pre and post operative hip scores. Six men and fourteen women were included. Average ages were 58 and 62.3 years respectively. The average diameters of the explanted and re-implanted sockets were 50.7 and 54.6 mm respectively. Average time for revision of the cup was less than 5 minutes. The average duration of follow-up was 13.2 months. All patients were satisfied with their outcomes. This device simplifies the use of the Explant (TM) in removing well fixed BHR sockets with predictably minimal loss of host bone.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [31] Does surgical approach influence component positioning with Birmingham Hip Resurfacing?
    Myers, G. J. C.
    Morgan, D.
    McBryde, C. W.
    O'Dwyer, K.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 59 - 63
  • [32] Good midterm results after Birmingham hip resurfacing and total hip arthroplasty
    Vanlommel, Luc
    Mertens, Peter
    Brabants, Karl
    [J]. ACTA ORTHOPAEDICA BELGICA, 2020, 86 (02): : 243 - 248
  • [33] Revision Total Hip Arthroplasty with Retained Acetabular Component
    Adelani, Muyibat A.
    Mall, Nathan A.
    Nyazee, Humaa
    Clohisy, John C.
    Barrack, Robert L.
    Nunley, Ryan M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12): : 1015 - 1020
  • [34] The fate of well fixed cemented femoral components left in place at the time of revision of the acetabular component
    Peters, CL
    Kull, L
    Jacobs, JJ
    Rosenberg, AG
    Galante, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05): : 701 - 706
  • [35] Retention of a well-fixed acetabular component in the setting of acetabular osteolysis
    Pengde Kang
    Jing Yang
    Zongke Zhou
    Bin Shen
    Fuxing Pei
    [J]. International Orthopaedics, 2012, 36 : 949 - 954
  • [36] Retention of a well-fixed acetabular component in the setting of acetabular osteolysis
    Kang, Pengde
    Yang, Jing
    Zhou, Zongke
    Shen, Bin
    Pei, Fuxing
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (05) : 949 - 954
  • [37] Short-term Results of Birmingham Hip Resurfacing in the United States
    Nam, Denis
    Nunley, Ryan M.
    Ruh, Erin L.
    Engh, C. Anderson, Jr.
    Rogerson, John S.
    Brooks, Peter J.
    Raterman, Stephen J.
    Su, Edwin P.
    Barrack, Robert L.
    [J]. ORTHOPEDICS, 2015, 38 (08) : E715 - E721
  • [38] Midterm results of the Birmingham hip resurfacing: a single-surgeon series
    Richard Lass
    Ulrich Bechler
    Bernhard Springer
    Kilian Rueckl
    Carola Hanreich
    Friedrich Boettner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1041 - 1048
  • [39] Midterm results of the Birmingham hip resurfacing: a single-surgeon series
    Lass, Richard
    Bechler, Ulrich
    Springer, Bernhard
    Rueckl, Kilian
    Hanreich, Carola
    Boettner, Friedrich
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 1041 - 1048
  • [40] Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: A biomechanical validation
    Wegrzyn, Julien
    Thoreson, Andrew R.
    Guyen, Olivier
    Lewallen, David G.
    An, Kai-Nan
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (06) : 991 - 997