Revision Total Hip Arthroplasty with Retained Acetabular Component

被引:24
|
作者
Adelani, Muyibat A. [1 ]
Mall, Nathan A. [1 ]
Nyazee, Humaa [1 ]
Clohisy, John C. [1 ]
Barrack, Robert L. [1 ]
Nunley, Ryan M. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
来源
关键词
ISOLATED LINER EXCHANGE; POLYETHYLENE LINER; COMBINED ANTEVERSION; PELVIC OSTEOLYSIS; METAL SHELL; FOLLOW-UP; CEMENTATION; REPLACEMENT; DISLOCATION; OUTCOMES;
D O I
10.2106/JBJS.L.01177
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Aseptic loosening and osteolysis commonly limit the survivorship of total hip prostheses. Retention of a well-fixed acetabular component, rather than full acetabular revision, has multiple advantages, but questions have lingered regarding the clinical success and prosthetic survivorship following this procedure. We examined the impact of acetabular component position, polyethylene type, liner insertion technique, femoral head size, and simultaneous revision of the entire femoral component (as opposed to head and liner exchange) or bone-grafting on mid-term to long-term prosthetic survival following such limited revisions. Methods: One hundred hips in 100 patients with osteolysis, polyethylene wear, or femoral component loosening underwent revision total hip arthroplasty with retention of the acetabular component. Acetabular component inclination and anteversion were measured on prerevision radiographs and were categorized according to predetermined positional safe zones (inclination of 35 degrees to 55 degrees and anteversion of 5 degrees to 25 degrees). Operative reports were reviewed for femoral head size, polyethylene liner type (conventional or highly cross-linked), liner insertion technique (use of the existing locking mechanism or cementation), whether the patient had revision of the entire femoral component, and use of bone graft. Outcomes of interest included the Harris hip score, University of California at Los Angeles (UCLA) activity score, episodes of instability, and need for repeat revision. Results: At an average of 6.6 years (range, two to fourteen years) postoperatively, the Harris hip and UCLA activity scores were both significantly improved compared with the preoperative scores (p < 0.0001 and p < 0.01, respectively). Overall, the failure rate was 13%. In addition, 6% of the patients had postoperative instability. Hips in which the acetabular component was outside of the safe zone for inclination had a higher rate of failure (p = 0.048). Use of conventional, rather than highly cross-linked, polyethylene at the time of revision was also associated with an increased rate of repeat revision (p = 0.025). Conclusions: Revision total hip arthroplasty with retention of the acetabular component is associated with good outcomes in hips with an appropriately positioned, well-fixed acetabular component. Acetabular components outside the safe zone for inclination were at a higher risk for failure, as was use of conventional polyethylene.
引用
收藏
页码:1015 / 1020
页数:6
相关论文
共 50 条
  • [1] The fate of stable cemented acetabular components retained during revision of a femoral component of a total hip arthroplasty
    Berger, RA
    Quigley, LR
    Jacobs, JJ
    Sheinkop, MB
    Rosenberg, AG
    Galante, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12): : 1682 - 1691
  • [2] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    [J]. CHIRURG, 2010, 81 (04): : 284 - +
  • [3] Fate of cementless acetabular components retained during revision total hip arthroplasty
    Beaulé, PE
    LeDuff, MJ
    Dorey, FJ
    Amstutz, HC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2288 - 2293
  • [4] One-Component Revision in Total Hip Arthroplasty: The Fate of the Retained Component
    Stathopoulos, Ioannis P.
    Lampropoulou-Adamidou, Kalliopi I.
    Vlamis, John A.
    Georgiades, George P.
    Hartofilakidis, George C.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (10): : 2007 - 2012
  • [5] Fate of the Retained Acetabular Component During Revision Total Hip Arthroplasty: A Meta-Analysis and Systematic Review
    Hanif, Muhammad
    Wang, Chongyan
    Lim, Chin Tat
    Noor, Syed Shahid
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (04): : 1130 - 1136
  • [6] Total hip arthroplasty with expansion acetabular component
    Tuekenmez, Mehmet
    [J]. TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2007, 27 (04): : 528 - 532
  • [7] REVISION TOTAL HIP-ARTHROPLASTY USING A CEMENTLESS ACETABULAR COMPONENT - TECHNIQUE AND RESULTS
    SILVERTON, CD
    ROSENBERG, AG
    SHEINKOP, MB
    KULL, LR
    GALANTE, JO
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (319) : 201 - 208
  • [8] Cernentless acetabular reconstruction in revision total hip arthroplasty
    Della Valle, CJ
    Berger, RA
    Rosenberg, AG
    Galante, JO
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 96 - 100
  • [9] Midterm Survivorship After Revision Total Hip Arthroplasty With a Custom Triflange Acetabular Component
    Gladnick, Brian P.
    Fehring, Keith A.
    Odum, Susan M.
    Christie, Michael J.
    DeBoer, David K.
    Fehring, Thomas K.
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 500 - 504
  • [10] Revision hip arthroplasty using a porous tantalum acetabular component
    Miettinen, Hannu J. A.
    Miettinen, Simo S. A.
    Kettunen, Jukka S.
    Jalkanen, Jussi
    Kroger, Heikki
    [J]. HIP INTERNATIONAL, 2021, 31 (06) : 782 - 788