Enhancing magnetically collimated electron beams for breast cancer treatments

被引:0
|
作者
Ma, L [1 ]
Sun, M [1 ]
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
D O I
10.1118/1.1998058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop magnetically collimated electron beams and to study their feasibilities for breast tumor bed irradiations. Method and Materials: We constructed an enhanced magnetic collimator with a beam aperture of 5.5 cm from permanent magnets using high‐density Neodymium‐Fe compounds. The collimator is cylindrical in shape and can be mounted at the end of an electron cone. The magnetic field is symmetrically aligned with the beam axis. The central axis of the magnetic field was calculated via finite element analyses and validated with Hall probe measurements. To implement magnetically collimated electrons for breast tumor bed irradiations, we measured and modeled the central axis depth doses and dose profiles of magnetically collimated electron beams on a flat water phantom. An empirical pencil‐beam model was developed to calculate three‐dimension dose distributions of magnetically collimated electron beams in CT studies. We implemented the dose model for breast tumor bed treatment cases. Results: Based on the dose distributions of the fixed and the arc beams of magnetically collimated electrons on the flat water phantom, the entrance dose is significantly lower than the conventional electrons (< 30% of the maximum dose). When treating the breast tumor bed, conformal dose distributions to the tumor volume are achieved with magnetically collimated electrons in contrast to single enface beam dose distributions. Isodose surface such as 90% of the maximum dose can be used to fully cover a target volume at depth. Conclusion: It is feasible to produce magnetically collimated electron beams with appropriate beam apertures. Conformal dose distributions from magnetically collimated electrons potentially create new regimens for breast tumor bed treatments. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2026 / 2026
页数:1
相关论文
共 50 条
  • [31] Beam model for mutli-leaf collimated high energy electron beams
    Traneus, E.
    Vatanen, T.
    Lahtinen, T.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S28 - S29
  • [32] PHYSICAL ASPECTS OF PHOTON AND ELECTRON TREATMENTS FOR THE CURE OF BREAST-CANCER
    SIMPSON, LD
    MEDICAL PHYSICS, 1981, 8 (04) : 591 - 591
  • [33] outcomes and defects of Intraoperative radiotherapy with electron beams in breast cancer patients
    Jitwatcharakomol, Tanun
    Setakoranukul, Jiraporn
    Thephamongkhol, Kullathorn
    Chuthatisith, Suebwong
    Ratanawichitrasin, Adune
    Sirima, Naponwan
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S516 - S517
  • [34] Breast cancer treatments
    Clere, Nicolas
    ACTUALITES PHARMACEUTIQUES, 2016, 55 (558): : 20 - 25
  • [36] POSITIVE-ION DRAINAGE IN MAGNETICALLY FOCUSED ELECTRON BEAMS
    HINES, ME
    HOFFMAN, GW
    SALOOM, JA
    JOURNAL OF APPLIED PHYSICS, 1955, 26 (09) : 1157 - 1162
  • [37] SPACE CHARGE WAVES ALONG MAGNETICALLY FOCUSED ELECTRON BEAMS
    LABUS, J
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1957, 45 (06): : 854 - 861
  • [38] ON THE ELECTROSTATIC STABILITY OF NEUTRALIZED, MAGNETICALLY FOCUSED ELECTRON-BEAMS
    CUPERMAN, S
    PETRAN, F
    PLASMA PHYSICS AND CONTROLLED FUSION, 1984, 26 (02) : 485 - 487
  • [39] Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators
    Di Venanzio, Cristina
    Marinelli, Marco
    Tonnetti, Alessia
    Verona-Rinati, Gianluca
    Bagala, Paolo
    Falco, Maria Daniela
    Guerra, Antonio Stefano
    Pimpinella, Maria
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 329 - 335
  • [40] Characterization and dosimetry of photon multileaf collimated electron beams using Gafchromic film measurements
    Mutsakanyi, Stalyn
    du Plessis, Freek