Full-field laser Doppler blood-flow imaging and monitoring using an intelligent CMOS camera and area illumination

被引:1
|
作者
Serov, A [1 ]
Steinacher, B [1 ]
Lasser, T [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Imaging Opt & Engn, EPFL, CH-1015 Lausanne, Switzerland
关键词
laser Doppler; laser speckle; imaging; blood flow; CMOS image sensors;
D O I
10.1117/12.634657
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An apparatus for parallel, full-field, laser Doppler perfusion imaging has been developed and applied for measurements of blood flow in human skin. This new imaging system allows obtaining 2D flow maps or to monitor flux signals from a plurality of separate predetermined points simultaneously with a 2D matrix of photodetectors. The uniform area illumination is achieved with a highly multimode optical fiber. The detection part of the system is based on an intelligent CMOS camera (iMVS-155) with a built-in digital signal processor. The imaging time of the system is 4 times quicker than for conventional scanning laser Doppler imager. The performance of the system was tested on artificial samples demonstrating linear response to the velocity up to 3 mm/sec. Also, the results of the measurements obtained with the new system on human skin are reported.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [41] Mucosal blood flow measurements using laser Doppler perfusion monitoring
    Dag Arne Lihaug Hoff
    Hans Gregersen
    Jan Gunnar Hatlebakk
    World Journal of Gastroenterology, 2009, 15 (02) : 198 - 203
  • [42] EVALUATION OF BLOOD-FLOW IN HUMAN RECTAL TUMORS USING A LASER DOPPLER FLOWMETER
    ZOGRAFOS, GC
    IFTIKHAR, SY
    HARRISON, J
    MORRIS, DL
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1990, 16 (06): : 497 - 499
  • [43] Laser Doppler blood-flow imaging combined with topographical imaging of the sample - art. no. 608109
    Michaely, Roland
    Serov, Alexandre
    Jacquot, Pierre
    Lasser, Theo
    Multimodal Biomedical Imaging, 2006, 6081 : 8109 - 8109
  • [44] Mucosal blood flow measurements using laser Doppler perfusion monitoring
    Hoff, Dag Arne Lihaug
    Gregersen, Hans
    Hatlebakk, Jan Gunnar
    WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (02) : 198 - 203
  • [45] Spectral optical flow imaging - measuring full-field subpixel oscillations without a high-speed camera
    Slavic, J.
    Javh, J.
    Boltezar, M.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2018) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2018), 2018, : 1323 - 1330
  • [46] THE EFFECT OF BLOOD-GLUCOSE CHANGES ON RETINAL BLOOD-FLOW USING LASER DOPPLER VELOCIMETRY
    KOHNER, EM
    DAVIES, EG
    SULLIVAN, P
    CALDWELL, G
    DIABETOLOGIA, 1989, 32 (07) : A505 - A505
  • [47] MEASUREMENTS OF BLOOD-FLOW IN HUMAN RETINAL BLOOD-VESSELS USING LASER DOPPLER VELOCIMETRY
    TANAKA, T
    ROSS, B
    BENSIRA, I
    RIVA, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 480 - 480
  • [48] Identification of damage in plates using full-field measurement with a continuously scanning laser Doppler vibrometer system
    Chen, Da-Ming
    Xu, Y. F.
    Zhu, W. D.
    JOURNAL OF SOUND AND VIBRATION, 2018, 422 : 542 - 567
  • [49] LASER DOPPLER BLOOD-FLOW MONITORING IN RECONSTRUCTIVE VASCULAR-SURGERY - CASE-STUDIES
    SVENSSON, H
    BERGQVIST, D
    TAKOLANDER, R
    VASCULAR SURGERY, 1987, 21 (01): : 58 - 65
  • [50] A MODEL FOR MONITORING NERVE BLOOD-FLOW DURING EXPANSION BY LASER-DOPPLER FLOWMETRY IN THE RABBIT
    VANDERWEY, LP
    POLDER, TW
    HOOGBERGEN, MM
    SPAUWEN, PHM
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 1993, 117 (1-2) : 79 - 82