Full-field laser Doppler blood-flow imaging and monitoring using an intelligent CMOS camera and area illumination

被引:1
|
作者
Serov, A [1 ]
Steinacher, B [1 ]
Lasser, T [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Imaging Opt & Engn, EPFL, CH-1015 Lausanne, Switzerland
关键词
laser Doppler; laser speckle; imaging; blood flow; CMOS image sensors;
D O I
10.1117/12.634657
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An apparatus for parallel, full-field, laser Doppler perfusion imaging has been developed and applied for measurements of blood flow in human skin. This new imaging system allows obtaining 2D flow maps or to monitor flux signals from a plurality of separate predetermined points simultaneously with a 2D matrix of photodetectors. The uniform area illumination is achieved with a highly multimode optical fiber. The detection part of the system is based on an intelligent CMOS camera (iMVS-155) with a built-in digital signal processor. The imaging time of the system is 4 times quicker than for conventional scanning laser Doppler imager. The performance of the system was tested on artificial samples demonstrating linear response to the velocity up to 3 mm/sec. Also, the results of the measurements obtained with the new system on human skin are reported.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [31] Experimental comparison of perfusion imaging systems using multi-exposure laser speckle, single exposure laser speckle and full-field laser Doppler
    Thompson, Oliver
    Bakker, Jimmy
    Kloeze, Carla
    Hondebrink, Erwin
    Steenbergen, Wiendelt
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [32] Laser Doppler field sensor for high resolution flow velocity imaging without camera
    Voigt, Andreas
    Bayer, Christian
    Shirai, Katsuaki
    Buettner, Lars
    Czarske, Juergen
    APPLIED OPTICS, 2008, 47 (27) : 5028 - 5040
  • [33] COMPARISON OF LASER-DOPPLER PERFUSION IMAGING, LASER-DOPPLER FLOWMETRY, AND THERMOGRAPHIC IMAGING FOR ASSESSMENT OF BLOOD-FLOW IN HUMAN SKIN
    SEIFALIAN, AM
    STANSBY, G
    JACKSON, A
    HOWELL, K
    HAMILTON, G
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (01): : 65 - 69
  • [34] MONITORING OF SPINAL-CORD BLOOD-FLOW (SCBF) WITH LASER-DOPPLER FLOWMETRY
    LINDSBERG, PJ
    ONEILL, JT
    PAAKKARI, IA
    HALLENBECK, JM
    FEUERSTEIN, G
    STROKE, 1989, 20 (01) : 134 - 134
  • [35] EVALUATING BLOOD-FLOW IN FULL-THICKNESS SKIN-GRAFTS UTILIZING THE LASER DOPPLER
    MULVANEY, MJ
    SALASCHE, SJ
    GRABSKI, WJ
    JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1989, 15 (11): : 1178 - 1183
  • [36] In-vivo full-field measurement of microcirculatory blood flow velocity based on intelligent object identification
    Ye, Fei
    Yin, Songchao
    Li, Meirong
    Li, Yujie
    Zhong, Jingang
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (01)
  • [37] MONITORING BLOOD-FLOW TO COLORECTAL LIVER METASTASES USING LASER DOPPLER FLOWMETRY - THE EFFECT OF ANGIOTENSIN-II
    HEMINGWAY, DM
    ANGERSON, WJ
    ANDERSON, JH
    GOLDBERG, JA
    MCARDLE, CS
    COOKE, TG
    BRITISH JOURNAL OF CANCER, 1992, 66 (05) : 958 - 960
  • [38] LASER-DOPPLER PERFUSION IMAGING OF MICROVASCULAR BLOOD-FLOW IN RABBIT TENUISSIMUS MUSCLE
    LINDEN, M
    SIRSJO, A
    LINDBOM, L
    NILSSON, G
    GIDLOF, A
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04): : H1496 - H1500
  • [39] Image-guided simulation in comparison with laser speckle contrast imaging for full-field observation of blood flow in a microvasculature model
    Yang, Yamin
    Geng, Jinfa
    Zhang, Huan
    Chen, Chunxiao
    Li, Weitao
    Qian, Zhiyu
    Li, Siwen
    MICROVASCULAR RESEARCH, 2021, 133
  • [40] Imaging Blood Flow and Pulsation of Retinal Vessels with Full-Field Swept-Source OCT
    Spahr, H.
    Hillmann, D.
    Hain, C.
    Pfaffle, C.
    Sudkamp, H.
    Franke, G.
    Koch, P.
    Huttmann, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (12) : 1324 - 1330