A Case Study of an Optimal Detailed Analysis of a Standalone Photovoltaic/Battery System for Electricity Supply in Rural and Remote Areas

被引:7
|
作者
Falama, Ruben Zieba [1 ,2 ]
Yaouba [2 ,3 ]
Menga, Francis-Daniel [4 ]
Soulouknga, Marcel Hamda [5 ]
Mbakop, Fabrice Kwefeu [3 ]
Ben Salah, Chokri [6 ,7 ]
机构
[1] Univ Maroua, Higher Natl Sch Mines & Petr Ind, POB 46, Maroua, Cameroon
[2] Inst Geol & Min Res, Res Ctr Renewable Energy, POB 4110, Yaounde, Cameroon
[3] Univ tMaroua, Natl Adv Polytech Sch, Dept Renewable Energy, POB 46, Maroua, Cameroon
[4] Natl Ctr Technol Dev, Yaounde, Cameroon
[5] Higher Teacher Training Tech Coll Sarh, Sarh, Chad
[6] Univ Monastir, LASEE Lab, Monastir, Tunisia
[7] Univ Sousse, ISSAT Sousse, Sousse, Tunisia
关键词
ENERGY SYSTEM; OPTIMIZATION; ALGORITHMS; DESIGN;
D O I
10.1155/2022/7132589
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper focused on a techno-economic study of a standalone PV/battery system for electrical energy supply. For a particular case study in Cameroon, the system is optimally designed thanks to a double-objective firefly optimization algorithm, based on a defined operational strategy. The two objective functions simulated simultaneously using FA are: the cost of energy (COE) function and the function defining the loss of power supply probability (LPSP). Different optimal configurations of the system have been obtained on the Pareto front with respect to their LPSP. For a total load demand of 20196.7 kWh, the lowest cost configuration with LPSP of 0% is composed by a number of 63 modules and a battery capacity of 370.295 kWh. The related COE is 0.2587 $/kWh, corresponding to a total net present cost of 87422 $. However with this configuration, the energy of batteries could not be able solely to respond to the energy demand for 3 continuous days. In that case, the increase of the PV power production (by increasing the number of PV modules) could allow to the batteries to fulfil this deficiency. But this solution increases the investment cost to up to 11.17%, considering a system with 80 PV modules. Another solution consists in reducing the size of the battery bank to avoid its unnecessary oversizing. In this case, the COE and the system investment cost reduce to up to 28.77% for 1 day batteries' autonomy considered. The obtained results have demonstrated that the cost of a PV/battery system is mostly influenced by the batteries' size, while the system reliability is mostly related to the PV size.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Study of Photovoltaic/Hydrogen/Battery Bank System to Supply Energy to an Electric Vehicle
    Mebarki, Nasser-Eddine
    Rekioua, Toufik
    Rekioua, Djamila
    [J]. PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 841 - 846
  • [42] A FEASIBILITY STUDY: OFF-GRID PHOTOVOLTAIC SOLAR POWER SUPPLY TO THE REMOTE AREAS OF PAKISTAN
    Ali, Muhammad Azhar
    Yamin, Muhammad
    Arslan, Ch
    Farid, Usman
    Nasir, Abdul
    [J]. PAKISTAN JOURNAL OF AGRICULTURAL SCIENCES, 2020, 57 (05): : 1313 - 1316
  • [43] Techno-economic analysis and optimal sizing of a battery-based and hydrogen-based standalone photovoltaic/wind hybrid system for rural electrification in Cameroon based on meta-heuristic techniques
    Ngouleu, Clint Ameri Wankouo
    Kohole, Yemeli Wenceslas
    Fohagui, Fodoup Cyrille Vincelas
    Tchuen, Ghislain
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2023, 280
  • [44] Sizing of a Standalone PV System with Battery Storage for a Dairy: A Case Study from Chile
    Viveros, Pablo
    Wulff, Francisco
    Kristjanpoller, Fredy
    Nikulin, Christopher
    Grubessich, Tomas
    [J]. COMPLEXITY, 2020, 2020
  • [45] EXTREME LOW-MAINTENANCE, LEAD-ACID-BATTERY FOR PHOTOVOLTAIC POWER-SUPPLY SYSTEMS IN REMOTE, TROPICAL AREAS
    SHIRODKER, RP
    [J]. JOURNAL OF POWER SOURCES, 1995, 53 (02) : 255 - 260
  • [46] Planning the optimal solution for wastewater management in rural areas - case study
    Boguniewicz-Zablocka, Joanna
    Klosok-Bazan, Iwona
    Capodaglio, Andrea G.
    Ploskonka, Joanna
    [J]. 3RD SCIENTIFIC CONFERENCE ENVIRONMENTAL CHALLENGES IN CIVIL ENGINEERING (ECCE 2018), 2018, 174
  • [47] Luminescence Toxicological Analysis of Water Supply Systems in Dispersed Rural Areas: A Case Study in Boyaca, Colombia
    Ramos-Parra, Yadi Johaira
    Diaz-Gomez, Jaime
    Mesa-Torres, Monica Viviana
    Torres-Piraquive, Sergio David
    Zipa-Casas, Nohora Yaneth
    Suescun-Carrero, Sandra
    Medina-Alfonso, Mabel
    [J]. WATER, 2023, 15 (13)
  • [48] Feasibility Analysis and Development of Stand-Alone Hybrid Power Generation System for Remote Areas: A Case Study of Ethiopian Rural Area
    Bayu, Endeshaw Solomon
    Khan, Baseem
    Hagos, Issaias Gidey
    Mahela, Om Prakash
    Guerrero, Josep M.
    [J]. WIND, 2022, 2 (01): : 68 - 86
  • [49] A comprehensive study of battery-supercapacitor hybrid energy storage system for standalone PV power system in rural electrification
    Jing, Wenlong
    Lai, Chean Hung
    Wong, Wallace S. H.
    Wong, M. L. Dennis
    [J]. APPLIED ENERGY, 2018, 224 : 340 - 356
  • [50] Life cycle carbon emission flow analysis for electricity supply system: A case study of China
    Chen, G.
    Chen, B.
    Zhou, H.
    Dai, P.
    [J]. ENERGY POLICY, 2013, 61 : 1276 - 1284