A Case Study of an Optimal Detailed Analysis of a Standalone Photovoltaic/Battery System for Electricity Supply in Rural and Remote Areas

被引:7
|
作者
Falama, Ruben Zieba [1 ,2 ]
Yaouba [2 ,3 ]
Menga, Francis-Daniel [4 ]
Soulouknga, Marcel Hamda [5 ]
Mbakop, Fabrice Kwefeu [3 ]
Ben Salah, Chokri [6 ,7 ]
机构
[1] Univ Maroua, Higher Natl Sch Mines & Petr Ind, POB 46, Maroua, Cameroon
[2] Inst Geol & Min Res, Res Ctr Renewable Energy, POB 4110, Yaounde, Cameroon
[3] Univ tMaroua, Natl Adv Polytech Sch, Dept Renewable Energy, POB 46, Maroua, Cameroon
[4] Natl Ctr Technol Dev, Yaounde, Cameroon
[5] Higher Teacher Training Tech Coll Sarh, Sarh, Chad
[6] Univ Monastir, LASEE Lab, Monastir, Tunisia
[7] Univ Sousse, ISSAT Sousse, Sousse, Tunisia
关键词
ENERGY SYSTEM; OPTIMIZATION; ALGORITHMS; DESIGN;
D O I
10.1155/2022/7132589
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper focused on a techno-economic study of a standalone PV/battery system for electrical energy supply. For a particular case study in Cameroon, the system is optimally designed thanks to a double-objective firefly optimization algorithm, based on a defined operational strategy. The two objective functions simulated simultaneously using FA are: the cost of energy (COE) function and the function defining the loss of power supply probability (LPSP). Different optimal configurations of the system have been obtained on the Pareto front with respect to their LPSP. For a total load demand of 20196.7 kWh, the lowest cost configuration with LPSP of 0% is composed by a number of 63 modules and a battery capacity of 370.295 kWh. The related COE is 0.2587 $/kWh, corresponding to a total net present cost of 87422 $. However with this configuration, the energy of batteries could not be able solely to respond to the energy demand for 3 continuous days. In that case, the increase of the PV power production (by increasing the number of PV modules) could allow to the batteries to fulfil this deficiency. But this solution increases the investment cost to up to 11.17%, considering a system with 80 PV modules. Another solution consists in reducing the size of the battery bank to avoid its unnecessary oversizing. In this case, the COE and the system investment cost reduce to up to 28.77% for 1 day batteries' autonomy considered. The obtained results have demonstrated that the cost of a PV/battery system is mostly influenced by the batteries' size, while the system reliability is mostly related to the PV size.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Optimal Sizing of Hybrid Renewable Energy System for Electricity Production for Remote Areas
    Priyanka Anand
    Mohammad Rizwan
    Sarbjeet Kaur Bath
    Gulnar Perveen
    Vikram Kumar Kamboj
    [J]. Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2022, 46 : 1149 - 1174
  • [22] Optimal Sizing of Hybrid Renewable Energy System for Electricity Production for Remote Areas
    Anand, Priyanka
    Rizwan, Mohammad
    Bath, Sarbjeet Kaur
    Perveen, Gulnar
    Kamboj, Vikram Kumar
    [J]. IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2022, 46 (04) : 1149 - 1174
  • [23] Optimal Design and Techno-Economic Analysis of a Hybrid System to Supply a Remote Fishpond with Electricity and Heat
    Tomovic, Milan, V
    Klimenta, Dardan O.
    Milovanovic, Milos J.
    Perovic, Bojan D.
    Hinov, Nikolay L.
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2024, 30 (01) : 44 - 55
  • [24] Data-based analysis of the optimal direction of a photovoltaic system for remote sensor nodes for a case study in Germany
    Shen, Na
    Wu, Jian
    Molinar, Gabriela
    Stork, Wilhelm
    [J]. 2021 5TH INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2021), 2021, : 124 - 129
  • [25] A comparative case study of remote area power supply systems using photovoltaic-battery vs thermoelectric-battery configuration
    Tan, Lippong
    Date, Abhijit
    Zhang, Bingjie
    Singh, Baljit
    Ganguly, Sayantan
    [J]. 1ST INTERNATIONAL CONFERENCE ON ENERGY AND POWER, ICEP2016, 2017, 110 : 89 - 94
  • [26] Optimal Capacity and Cost Analysis of Battery Energy Storage System in Standalone Microgrid Considering Battery Lifetime
    Wongdet, Pinit
    Boonraksa, Terapong
    Boonraksa, Promphak
    Pinthurat, Watcharakorn
    Marungsri, Boonruang
    Hredzak, Branislav
    [J]. BATTERIES-BASEL, 2023, 9 (02):
  • [27] Feasibility Analysis of Standalone PV/Wind/Battery Hybrid Energy System for Rural Bangladesh
    Das, Himadry Shekhar
    Dey, Atanu
    Wei, Tan Chee
    Yatim, A. H. M.
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (02): : 402 - 412
  • [28] Standalone power system with photovoltaic and thermoelectric installations for power supply of remote monitoring and control stations for oil pipelines
    Belsky, A. A.
    Glukhanich, D. Y.
    [J]. RENEWABLE ENERGY FOCUS, 2023, 47
  • [29] Design and techno-economic assessment of a standalone photovoltaic-diesel-battery hybrid energy system for electrification of rural areas: A step towards sustainable development
    Adefarati, T.
    Bansal, R. C.
    Naidoo, R.
    Onaolapo, K. A.
    Bettayeb, M.
    Olulope, P. K.
    Sobowale, A. A.
    [J]. RENEWABLE ENERGY, 2024, 227
  • [30] Adaptive fuzzy logic control based optimal Hopfield neural network of standalone photovoltaic system with battery storage
    Arulmurugan, R.
    Suthanthiravanitha, N.