An off-line gating method for suppressing motion artifacts in ICUS sequence

被引:11
|
作者
Sun Zheng [1 ]
Yan Qi [2 ]
机构
[1] N China Elect Power Univ, Dept Elect & Commun Engn, Baoding 071003, Peoples R China
[2] Hebei Univ, Affiliated Hosp, Dept Internal Med, Baoding 071003, Peoples R China
关键词
Coronary artery; Intracoronary ultrasound (ICUS); Motion artifact; Gating; Image property; INTRACORONARY ULTRASOUND IMAGES;
D O I
10.1016/j.compbiomed.2010.09.006
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intracoronary ultrasound (ICUS) imaging, an invasive catheter-based imaging modality, has been widely used in clinical diagnosis of coronary artery diseases. Motion artifacts due to cyclic cardiac motion and pulsatile blood are the main factors that hinder the visualization of ICUS longitudinal cut and 3D vessel reconstruction from ICUS image sequence. The aim of this work is to propose an off-line gating method based on ICUS image properties to suppress motion artifacts for continuous pullback ICUS image sequences acquired in vivo covering several cardiac cycles without the help of ECG signals. Based on analysis of intensity features of each ICUS frame, a difference matrix is firstly constructed. Then, potential information about cardiac cycle is extracted from the matrix and the correspondence of each ICUS frame in successive cardiac cycles is obtained through finding a globally optimal path with the lowest cumulative difference value in the matrix. Finally, a subsequence of frames each acquired at the end-diastole of each cardiac cycle is selected to obtain the gated sequence. The main advantage of this method is that it is applicable to those ICUS sequences where the subject's heart rate may be irregular during image acquisition. Also, any high-level image analysis performed to ICUS images is not needed. Results are given for clinical image data of patients in order to validate the proposed method. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:860 / 868
页数:9
相关论文
共 50 条
  • [21] CONTROL ROD SEQUENCE EXCHANGES UTILIZING AN OFF-LINE PREDICTIVE CODE
    BYNUM, JR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 69 - 70
  • [22] PREDICTIVE RESPIRATORY GATING - A NEW METHOD TO REDUCE MOTION ARTIFACTS ON CT SCANS
    RITCHIE, CJ
    HSIEH, J
    GARD, MF
    GODWIN, JD
    KIM, YM
    CRAWFORD, CR
    RADIOLOGY, 1994, 190 (03) : 847 - 852
  • [23] A comprehensive analysis method of conducted EMI of an off-line converter
    He, JP
    Jiang, JG
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 529 - 532
  • [24] A New Method for Slant Calculation in Off-Line Handwriting Analysis
    Latypov, Rustam
    Stolov, Evgeni
    2018 41ST INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2018, : 480 - 483
  • [25] A Parallel Measuring Method for Robot Off-line Teaching Programming
    Xiao, W.
    Wei, D.
    Zhao, G.
    2018 11TH INTERNATIONAL WORKSHOP ON HUMAN FRIENDLY ROBOTICS (HFR), 2018, : 36 - 41
  • [26] New off-line identification method of induction motor parameters
    Pankratov, VV
    Zima, YA
    SIBERIAN RUSSIAN WORKSHOPS AND TUTORIALS ON ELECTRON DEVICES AND MATERIALS, EDM 2002, VOL 2, PROCEEDINGS, 2002, : 85 - 87
  • [27] A stroke extraction method for off-line recognition of Chinese characters
    Larmagnac, JP
    Dinet, E
    DOCUMENT RECOGNITION AND RETRIEVAL VII, 2000, 3967 : 32 - 41
  • [28] Off-line detection of a quasi-periodically recurring fragment in a numerical sequence
    A. V. Kel’manov
    Proceedings of the Steklov Institute of Mathematics, 2008, 263 : 84 - 92
  • [29] Robot Modeling, Motion Simulation and Off-line Programming Based on SolidWorks API
    Bratovanov, Nikolay
    2019 THIRD IEEE INTERNATIONAL CONFERENCE ON ROBOTIC COMPUTING (IRC 2019), 2019, : 574 - 579
  • [30] Off-Line Detection of a Quasi-Periodically Recurring Fragment in a Numerical Sequence
    Kel'manov, A. V.
    PROCEEDINGS OF THE STEKLOV INSTITUTE OF MATHEMATICS, 2008, 263 (Suppl 2) : S84 - S92