Needle trap sampling thermal-desorption resonance enhanced multiphoton ionization time-of-flight mass spectrometry for analysis of marine diesel engine exhaust

被引:12
|
作者
Kleeblatt, Juliane [1 ,2 ]
Stengel, Benjamin [3 ]
Radischat, Christian [1 ,2 ]
Passig, Johannes [1 ,2 ]
Streibel, Thorsten [1 ,2 ]
Sippula, Olli [4 ]
Rabe, Rom [3 ]
Harndorf, Horst [3 ]
Zimmermann, Ralf [1 ,2 ]
机构
[1] Univ Rostock, Inst Chem, Joint Mass Spectrometry Ctr, Chair Analyt Chem, D-18059 Rostock, Germany
[2] Helmholtz Zentrum Munchen, Comprehens Mol Analyt, Joint Mass Spectrometry Ctr, D-85764 Neuherberg, Germany
[3] Univ Rostock, Chair Piston Machines & Internal Combust Engines, Fac Mech Engn & Marine Technol, D-18059 Rostock, Germany
[4] Univ Eastern Finland, Dept Environm Sci, Fine Particle & Aerosol Technol Lab, FI-70211 Kuopio, Finland
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; SINGLE-PHOTON IONIZATION; COMPLEX GAS-MIXTURES; REAL-TIME; ONLINE CHARACTERIZATION; PARTICULATE MATTER; EMISSIONS; PAH; FUELS; CHROMATOGRAPHY;
D O I
10.1039/c5ay00321k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this publication is to present the results of the ship diesel engine measurement campaign in Rostock. A single-cylinder diesel research engine was operated on different engine loads and two different fuel types - diesel fuel (DF, diesel DIN-EN 590) and heavy fuel oil (HFO 180). The gaseous phase was directly trapped on needle trap devices (NTDs), thermal desorbed in a GC inlet and analyzed by resonance enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS). The photoionization was realized using two different wavelengths - 266 nm and 248 nm. With REMPI mainly aromatic substances are softly ionized, thus, especially aromatics and polycyclic aromatic hydrocarbons (PAH) were found in gaseous samples of exhaust. Differences between the two fuel qualities are obviously visible. While DF exhaust contains smaller molecules (mass-to-charge ratio between 75 and 220) higher molecular substances (up to m/z 280) were found in exhaust of HFO. For example, benzene and its methylated derivatives were detected only in the diesel exhaust. Phenanthrene and alkylphenanthrenes are the major compounds resulting from combustion of heavy fuel oil. For confirmation of measured substances in exhaust the modified gas chromatographic device was complemented by a GC column.
引用
收藏
页码:3608 / 3617
页数:10
相关论文
共 50 条
  • [31] Rapid Analysis of Gasoline-Contaminated Soil Using Multiphoton Ionization/Time-of-Flight Mass Spectrometry
    Tomohiro Uchimura
    Yuki Hironaka
    Misako Mori
    Analytical Sciences, 2013, 29 : 85 - 88
  • [32] Rapid Analysis of Gasoline-Contaminated Soil Using Multiphoton Ionization/Time-of-Flight Mass Spectrometry
    Uchimura, Tomohiro
    Hironaka, Yuki
    Mori, Misako
    ANALYTICAL SCIENCES, 2013, 29 (01) : 85 - 88
  • [33] Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing
    Adam, T. W.
    Clairotte, M.
    Streibel, T.
    Elsasser, M.
    Pommeres, A.
    Manfredi, U.
    Carriero, M.
    Martini, G.
    Sklorz, M.
    Krasenbrink, A.
    Astorga, C.
    Zimmermann, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 273 - 276
  • [34] Sample preparation conditions for the real-time measurement of W/O emulsions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Minori Minami
    Shion Nakata
    Tomohiro Uchimura
    Analytical Sciences, 2024, 40 : 573 - 577
  • [35] Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing
    T. W. Adam
    M. Clairotte
    T. Streibel
    M. Elsasser
    A. Pommeres
    U. Manfredi
    M. Carriero
    G. Martini
    M. Sklorz
    A. Krasenbrink
    C. Astorga
    R. Zimmermann
    Analytical and Bioanalytical Chemistry, 2012, 404 : 273 - 276
  • [36] ENHANCED MASS RESOLUTION IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETRY
    SCHUERCH, S
    SCHAER, M
    BOERNSEN, KO
    SCHLUNEGGER, UP
    BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (11) : 695 - 700
  • [37] Sample preparation conditions for the real-time measurement of W/O emulsions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Minami, Minori
    Nakata, Shion
    Uchimura, Tomohiro
    ANALYTICAL SCIENCES, 2024, 40 (03) : 573 - 577
  • [38] Laser ablation with resonance-enhanced multiphoton ionization time-of-flight mass spectrometry for determining aromatic lignin volatilization products from biomass
    Mukarakate, Calvin
    Scheer, Adam M.
    Robichaud, David J.
    Jarvis, Mark W.
    David, Donald E.
    Ellison, G. Barney
    Nimlos, Mark R.
    Davis, Mark F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [39] THIN-LAYER CHROMATOGRAPHY LASER-DESORPTION OF PEPTIDES FOLLOWED BY MULTIPHOTON IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY
    KRUTCHINSKY, AN
    DOLGIN, AI
    UTSAL, OG
    KHODORKOVSKI, AM
    JOURNAL OF MASS SPECTROMETRY, 1995, 30 (02): : 375 - 379
  • [40] Effect of surface-enhanced laser desorption/ionization time-of-flight mass spectrometry on identifing biomarkers of endometriosis
    ZHANG HongFENG JieCHANG XiaohongLI ZhongxingWU Xiaoyi and CUI Heng Gynecological Oncology CenterPeking University Peoples HospitalBeijing ChinaBeijing DeYi Biological Medical Technology CoLtdBeijingChina
    中华医学杂志(英文版), 2009, (04) : 373 - 376