Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing

被引:0
|
作者
T. W. Adam
M. Clairotte
T. Streibel
M. Elsasser
A. Pommeres
U. Manfredi
M. Carriero
G. Martini
M. Sklorz
A. Krasenbrink
C. Astorga
R. Zimmermann
机构
[1] European Commission Joint Research Centre,Analytical Chemistry/Joint Mass Spectrometry Centre, Institute of Chemistry
[2] Institute for Environment and Sustainability,undefined
[3] Transport and Air Quality Unit,undefined
[4] Cooperation Group Complex Molecular Systems (CMA)/Joint Mass Spectrometry Centre (JMSC),undefined
[5] University of Rostock,undefined
[6] European Commission Joint Research Centre,undefined
[7] Institute for Energy and Transport,undefined
[8] Sustainable Transport Unit,undefined
来源
关键词
Fuels; Mass spectrometry/ICP-MS; Organic compounds/trace organic compounds;
D O I
暂无
中图分类号
学科分类号
摘要
Resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS) is a robust method for real-time analysis of monocyclic and polycyclic aromatic hydrocarbons in complex emissions. A mobile system has been developed which enables direct analysis on site. In this paper, we utilize a multicomponent calibration scheme based on the analytes’ photo-ionisation cross-sections relative to a calibrated species. This allows semi-quantification of a great number of components by only calibrating one compound of choice, here toluene. The cross-sections were determined by injecting nebulised solutions of aromatic compounds into the TOF-MS ion source with the help of a HPLC pump. Then, REMPI-TOF-MS was implemented at various chassis dynamometers and test cells and the exhaust of the following vehicles and engines investigated: a compression ignition light-duty (LD) passenger car, a compression ignition LD van, two spark ignition LD passenger cars, 2 two-stroke mopeds, and a two-stroke engine of a string gas trimmer. The quantitative time profiles of benzene are shown. The results indicate that two-stroke engines are a significant source for toxic and cancerogenic compounds. Air pollution and health effects caused by gardening equipment might still be underestimated.
引用
收藏
页码:273 / 276
页数:3
相关论文
共 50 条
  • [1] Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing
    Adam, T. W.
    Clairotte, M.
    Streibel, T.
    Elsasser, M.
    Pommeres, A.
    Manfredi, U.
    Carriero, M.
    Martini, G.
    Sklorz, M.
    Krasenbrink, A.
    Astorga, C.
    Zimmermann, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 273 - 276
  • [2] Real-time quantitative analysis of combustion-generated polycyclic aromatic hydrocarbons by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Gittins, CM
    Castaldi, MJ
    Senkan, SM
    Rohlfing, EA
    ANALYTICAL CHEMISTRY, 1997, 69 (03) : 286 - 293
  • [3] Real-time analysis of organic compounds in ship engine aerosol emissions using resonance-enhanced multiphoton ionisation and proton transfer mass spectrometry
    Christian Radischat
    Olli Sippula
    Benjamin Stengel
    Sophie Klingbeil
    Martin Sklorz
    Rom Rabe
    Thorsten Streibel
    Horst Harndorf
    Ralf Zimmermann
    Analytical and Bioanalytical Chemistry, 2015, 407 : 5939 - 5951
  • [4] Sample preparation conditions for the real-time measurement of W/O emulsions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Minori Minami
    Shion Nakata
    Tomohiro Uchimura
    Analytical Sciences, 2024, 40 : 573 - 577
  • [5] Real-time analysis of organic compounds in ship engine aerosol emissions using resonance-enhanced multiphoton ionisation and proton transfer mass spectrometry
    Radischat, Christian
    Sippula, Olli
    Stengel, Benjamin
    Klingbeil, Sophie
    Sklorz, Martin
    Rabe, Rom
    Streibel, Thorsten
    Harndorf, Horst
    Zimmermann, Ralf
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (20) : 5939 - 5951
  • [6] Sample preparation conditions for the real-time measurement of W/O emulsions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Minami, Minori
    Nakata, Shion
    Uchimura, Tomohiro
    ANALYTICAL SCIENCES, 2024, 40 (03) : 573 - 577
  • [7] Real-time, on-line characterization of diesel generator air toxic emissions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Oudejans, L
    Touati, A
    Gullett, BK
    ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2517 - 2524
  • [8] Detection of styrene impurities in phenylacetylene by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry
    Tzeng, WB
    Narayanan, K
    Lin, JL
    APPLIED SPECTROSCOPY, 1999, 53 (06) : 731 - 734
  • [9] Application of resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS) for on-line trace analysis of combustion- and pyrolysis products in technical processes
    Zimmermann, R
    Heger, HJ
    Dorfner, R
    Kettrup, A
    Boesl, U
    COMBUSTION DIAGNOSTICS, 1997, 3108 : 10 - 20
  • [10] Analysis of biomass and its combustion products by means of resonance enhanced multiphoton ionisation time-of-flight mass spectrometry and IR laser desorption
    Hauler, T. E.
    Zimmermann, R.
    Boesl, U.
    SECOND INTERNATIONAL CONFERENCE ON OPTICAL AND LASER DIAGNOSTICS, 2006, 45 : 231 - 231