Acetabular revision in total hip replacement with a press-fit cup

被引:24
|
作者
Elke, R [1 ]
Berli, B [1 ]
Wagner, A [1 ]
Morscher, EW [1 ]
机构
[1] Univ Basel, Orthopaed Dept, CH-4031 Basel, Switzerland
来源
关键词
D O I
10.1302/0301-620X.85B8.13590
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5 to 10.5) were available for clinical and radiological review. There was no further revision of a press-fit cup for aseptic loosening. Radiological assessment revealed osteolysis in three hips. Of the original 171 hips there was cranial and medial migration of up to 6 mm at two years in 44 (26%). No further migration was seen after the second post-operative year. Acetabular revision without screws is possible with excellent medium-term results in well selected patients.
引用
收藏
页码:1114 / 1119
页数:6
相关论文
共 50 条
  • [31] Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: Discussion of a biomechanical study
    Kanda A.
    Kaneko K.
    Obayashi O.
    Mogami A.
    Iwase H.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (4) : 417 - 424
  • [32] Cup-on-cup technique: a reliable management solution for severe acetabular bone loss in revision total hip replacement
    Chiarlone, Francesco
    Cavagnaro, Luca
    Zanirato, Andrea
    Alessio Mazzola, Mattia
    Lovisolo, Stefano
    Mosconi, Lorenzo
    Felli, Lamberto
    Burastero, Giorgio
    [J]. HIP INTERNATIONAL, 2020, 30 (1_SUPPL) : 12 - 18
  • [33] Acetabular component deformation with press-fit fixation
    Squire, Matthew
    Griffin, William L.
    Mason, Bohannon
    Peindl, Richard D.
    Odum, Susan
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 72 - 77
  • [34] Revision hip replacement with retention of the acetabular component for intrapelvic cup migration
    Sciberras, Nadia C.
    Bharadwaj, Ravi
    Holt, Graeme
    Khan, Aman
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2014, 25 (01): : 84 - 86
  • [35] ACETABULAR CUP FAILURE AFTER TOTAL HIP-REPLACEMENT
    HARLEY, JM
    BOSTON, DA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02): : 222 - 224
  • [36] Acetabular Osteolysis in Total Hip Replacement - When to Retain the Cup?
    Lutz, B.
    Faschingbauer, M.
    Bieger, R.
    Reichel, H.
    Kappe, T.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2016, 154 (04): : 377 - 384
  • [37] Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup
    Kaipel, Martin
    Prenner, Anton
    Bachl, Sebastian
    Farr, Sebastian
    Sinz, Guenter
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2014, 126 (7-8) : 208 - 211
  • [38] Effect of interposed tissue and contamination on the initial stability of a highly porous press-fit acetabular cup
    Wiznia, Daniel H.
    Joyal, Garrett
    Schmidig, Gregg
    Rajaravivarma, Raga
    Lokesh, Raja
    Schwartzkopf, Ran
    Iorio, Richard
    Long, William J.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (05) : 1117 - 1122
  • [39] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511
  • [40] The influence of cavity preparation and press-fit cup implantation on restoring the hip rotation center
    Messer-Hannemann, Philipp
    Baetz, Johanna
    Lampe, Frank
    Klein, Anke
    Pueschel, Klaus
    Campbell, Graeme M.
    Morlock, Michael
    [J]. CLINICAL BIOMECHANICS, 2019, 63 : 185 - 192